Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtre
Ajouter des filtres








Gamme d'année
1.
Chinese Journal of Cerebrovascular Diseases ; (12): 235-239, 2017.
Article Dans Chinois | WPRIM | ID: wpr-613965

Résumé

Objective To investigate the safety and effectiveness of using low-profile visualized intraluminal support (LVIS) stents for the treatment of aneurysms in the small intracranial vessels (diameter <2.5 mm).Methods Between October 2014 and April 2016,the clinical data of all 30 patients with intracranial saccular aneurysm treated with LVIS stents with the small parent arteries <2.5 mm in diameter in Changhai Hospital,the Second Military Medical University were analyzed retrospectively,including 7 ruptured aneurysms and 23 unruptured aneurysms.The anterior circulation aneurysm accounted for 93.3% (n=28),and the diameters of the parent arteries were 1.6-2.4 mm.The complications associated with surgery,angiography,clinical outcomes,and mid-term follow-up data were analyzed.Results The success rate of stent implantation was 100%.Immediate embolization results:Raymond grade Ⅰ in 12 cases (40.0%),Raymond grade Ⅱ in 11 cases (36.7%),and Raymond grade Ⅲ in 7 cases (23.3%).Complications occurred in 2 cases,including one perforating artery occlusion and one intraoperative rupture.Twenty-five patients accepted the angiographic follow-up (Raymond grade Ⅰ in 21 cases,grade Ⅱ in 3 cases,and grade Ⅲ in 1 case).The follow-up time ranged from 4 to 14 months,with an average of 8.1± 2.6 months.One patient had asymptomatic intracranial artery stenosis in the distal end of the stent.No new neurological dysfunction or death occurred.Conclusion The deployment of LVIS stents in small vessels is safe and feasible,the effect of mid-term follow-up is better.However,a larger sample study and long-term follow-up results are needed.

2.
Tianjin Medical Journal ; (12): 184-186, 2017.
Article Dans Chinois | WPRIM | ID: wpr-507263

Résumé

Objective To investigate the relationship between gene polymorphisms of homocysteine (Hcy), metabolic enzymes methylenetetrahydrofolate reductase MTHFR C677T and chronic pulmonary heart disease (CPHD). Methods The gene polymorphisms of MTHFR C677T were determined by the polymerase chain reaction-restriction fragment length polymorphism(PCR-RFLP)in CPHD patients (n=120) and healthy control (HC, n=120), and genotyping was carried on. The automatic biochemistry analyzer was used to detect the level of Hcy and other related biochemical indicators. Results There was significant difference in Hcy level between the CPHD group and HC group (P<0.05). The mutation frequencies of CC, CT and TT were 24.17%, 43.33%and 32.50%, 35.00%, 47.50%and 17.50%in the CPHD group and HC group. The mutation frequencies of allele C/T were 45.83%and 54.17%in HC group, and 58.75%and 41.25%in control group. There was significant difference in the overall frequency distribution between the three genotypes (χ2 =8.010, P<0.05). The frequency of T allele was significantly higher in CPHD group than that in control group (χ2=8.025,P<0.05). Conclusion The increased Hcy and its metabolic enzyme MTHFR C677T may be involved in the occurrence and development of CPHD.

3.
Chinese Journal of Cerebrovascular Diseases ; (12): 577-580, 2015.
Article Dans Chinois | WPRIM | ID: wpr-482237

Résumé

Objective To investigate the safety and efficacy of domestic contrast iodixanol injection in the application of interventional neuroradiology. Methods A total of 442 patients from 11 research centers using iodixanol injection for whole brain DSA examination or interventional therapy were enrolled in a prospective,multicenter,and non-controlled clinical trial. The recording and evaluation indicators included the adverse reactions after drug treatment,changes of creatinine and urea nitrogen indicators before and after drug treatment,DSA types,DSA effects,the dosage of contrast agent,etc. The renal function damage, incidence of adverse drug reactions,and image quality were counted and analyzed. Results All the 442 patients were completed the examination or treatment. (1)All the results of intraoperative angiography achieved excellent,including 98. 2% (n = 434)were excellent and 1. 8% (n = 8)were good. There were significant differences in the comparison of angiographic results in the 4 different types of DSA (SIEMENS,PHILIPS,GE,and TOSHIBA)(χ2 = 31. 518,P 44. 2 μmol / L. There was no urea nitrogen abnormality of clinical signifi-cance. None of the patients had renal insufficiency. (3)Three patients had adverse drug reaction (0. 7%) during procedure,including 2 patients had dermal allergic reactions and 1 patient had transient blurred vision. Conclusion Domestic iodixanol injection is safe and effective and has less adverse reaction in the clinical application of interventional neuroradiology. The different types of DSA may impact on the contrast image quality.

SÉLECTION CITATIONS
Détails de la recherche