1.
Journal of Laboratory Medicine and Quality Assurance ; : 25-43, 2010.
Article Dans Coréen | WPRIM | ID: wpr-96804

Résumé

Four trials of external quality assessment in diagnostic hematology were performed in 2009 with average 946 participating laboratories in Korea. We performed quality assessment for white blood cell count, hemoglobin, hematocrit, red blood cell count, platelet count, blood cell morphology, prothrombin time and activated partial thromboplastin time. The response rate was more than 98.2%. The coefficients of variation in hemoglobin, hematocrit and RBC count were stable but variable in platelet count and WBC count according to measuring cell counters. Test results of blood cell morphology showed variation among various cell morphologies.


Sujets)
Cellules sanguines , Numération cellulaire , Numération des érythrocytes , Hématocrite , Hématologie , Hémoglobines , Corée , Numération des leucocytes , Temps partiel de thromboplastine , Numération des plaquettes , Temps de prothrombine
2.
Journal of Laboratory Medicine and Quality Assurance ; : 219-224, 2006.
Article Dans Coréen | WPRIM | ID: wpr-167583

Résumé

BACKGROUND: Recent advances of hematology analyzers have improved performance of leukocyte differential counts and have reduced work load of clinical hematology laboratories. We evaluated CELL-DYN Sapphire (Abbott Diagnostics, Santa Clara, CA, USA) performance on leukocyte differential counts according to Clinical and Laboratory Standards Institute (CLSI) document H20-A. METHODS: We evaluated imprecision (short term imprecision from duplication of 147 patients' sample and long term imprecision from three level commercial controls) and accuracy (n=462) of leukocyte differential counts of CELL-DYN Sapphire and compared with those of Sysmex XE-2100 (TOA Medical Electronics Co., Kobe, Japan), ADVIA 120 (Bayer Diagnostics, Tarrytown, NY, USA) and Beckman Coulter LH 750 (Beckman Coulter, Miami, FL, USA). RESULTS: The imprecision of CELL-DYN Sapphire for neutrophils and lymphocytes differentials was low with coefficients of variation (CV) from 1.4 to 6.2%, but the imprecision for basophils was high with CV from 34.7 to 79.6%. The correlation with manual count was good in samples without flags (n=314), with the exception of basophils (r: neutrophils, 0.921; lymphocytes, 0.921; monocytes, 0.653; eosinophils, 0.869; basophils 0.272). The correlation with other hematology analyzers was high except basophils (r: neutrophils, 0.969-0.986; lymphocytes, 0.986-0.990; monocytes, 0.787-0.887; eosinophils, 0.881-0.962; basophils 0.086-0.327). CONCLUSION: The performance on leukocyte differential counts of CELL-DYN Sapphire is comparable to Sysmex XE-2100, ADVIA 120 and Beckman Coulter LH 750. In regards of enumeration of basophils, the comparison with manual counts and other hematology analyzers shows poor agreement.


Sujets)
Oxyde d'aluminium , Granulocytes basophiles , Électronique médicale , Granulocytes éosinophiles , Hématologie , Leucocytes , Lymphocytes , Monocytes , Granulocytes neutrophiles