RÉSUMÉ
The purpose of this study was to evaluate acrylonitrile butadiene styrene (ABS) and polyamide implants in rabbits submitted to evisceration at the macroscopic and microstructure level and to assess clinical response and histopathological changes as well. For the experimental study implants of 12mm diameter were prepared by rapid prototyping, weighed and the outer and inner surfaces evaluated macroscopically and by electron microscopy. In addition, a compression test was performed and ultrastructural damage was then determined. After evisceration of the left eyeball, nine New Zealand rabbits received ABS implants and nine others received polyamide implants. The animals were assessed daily for 15 days after surgery and every seven days until the end of the study (90 days). Histopathological evaluation was performed at 15, 45 and 90 days after surgery. The ABS implants weighed approximately 0.44g, while the polyamide ones weighed 0.61g. Scanning electron microscopy demonstrated that the ABS implants had regular-sized, equidistant micropores, while the polyamide ones showed micropores of various sizes. The force required to fracture the ABS implant was 14.39 ±0.60 Mpa, while for the polyamide one, it was 16.80 ±1.05 Mpa. Fifteen days after surgery, we observed centripetal tissue infiltration and scarce inflammatory infiltrate. Implants may be used in the filling of anophthalmic cavities, because they are inert, biocompatible and allow tissue integration.(AU)
Avaliou-se a macroscopia, a microestrutura, a resposta clínica e histopatológica de implantes de acrilonitrila butadieno estireno (ABS) e poliamida em coelhos submetidos à evisceração. Para o estudo experimental, os implantes foram elaborados por meio de prototipagem rápida, com 12mm de diâmetro, pesados e tiveram suas superfícies avaliadas macroscopicamente e por microscopia eletrônica de varredura. Adicionalmente, foi realizado ensaio de compressão para determinar a força necessária para fraturar os implantes. Após a evisceração do olho esquerdo, nove coelhos da raça Nova Zelândia receberam implantes de poliamida e nove outros receberam implantes de ABS. Os animais foram avaliados diariamente nos primeiros 15 dias após a cirurgia e a cada sete dias até o fim do período experimental (90 dias). Avaliação histopatológica foi realizada aos 15, 45 e 90 dias após a cirurgia. Os implantes de ABS pesaram 0,44g, e os de poliamida 0,61g. A microscopia eletrônica de varredura demonstrou que os implantes de ABS eram formados por microporos equidistantes, enquanto os de poliamida apresentavam microporos de vários tamanhos. A força necessária para fraturar os implantes de ABS foi de 14.39±0.60 Mpa, enquanto para os de poliamida foi de 16.80±1.05Mpa. Quinze dias após a cirurgia, foi observada infiltração fibrovascular centrípeta. Os implantes podem ser utilizados para correção de cavidades anoftálmicas por se mostrarem inertes, biocompatíveis e permitirem a infiltração tecidual.(AU)
Sujet(s)
Animaux , Lapins , Matériaux biocompatibles/analyse , Éviscération du bulbe oculaire/médecine vétérinaire , Oeil artificiel/médecine vétérinaire , Polymères , Acrylonitrile/analyse , Butadiènes/analyse , Microscopie électronique à balayage/médecine vétérinaire , NylonsRÉSUMÉ
The purpose of this study was to evaluate the macroscopy and microstructure of a double setting alpha-tricalcium phosphate bone cement sphere provided with interconnection channels (alpha-TCP-i), as well as the integration of the implant with the rabbits' orbital tissue, through macroscopic analysis and histopathology. The external and internal surfaces of the alpha-TCP-i were evaluated macroscopically and by electron microscopy. Twelve New Zealand rabbits received 12mm implants of alpha-TCP-i following enucleation of the left eye. The clinical assessment was undertaken daily during the first 15 days, followed by fortnightly assessment until the end of the study period. For the morphological analysis, exenteration was performed in 3 animals per experimental period (15, 45, 90 and 180 days). The external and internal surfaces of the implant appeared solid, smooth and compact, with six channels which interconnected centrally. The micro-architecture was characterized by the formation of columns of hexagonal crystals. No signs of infection, exposure, dehiscence of sutures or extrusion of the implant were noted in any of the animals during the entire period of the study. The morphological evaluation demonstrated the presence of a thin capsule around the implant, from whence appeared fibro-vascular projections, which penetrated it through the interconnecting channels. In the first days after the insertion of the implant, an intense inflammatory reaction was noted. At 180 days, however, there were no signs of inflammation. The alpha-tricalcium phosphate cement implant was well tolerated in this rabbit model and appeared to be relatively inert with some fibrovascular ingrowth through the large channels.
Avaliaram-se a macroscopia e a microestrutura de esferas compostas por cimento ósseo de alfa-fosfato tricálcico de dupla pega munido de canais de interconexão (alfa-TCP-i) e a integração do implante ao tecido orbital de coelhos através de análise macroscópica e histopatológica. A superfície interna e externa do alfa-TCP-i foi avaliada macroscopicamente e por microscopia eletrônica. Após enucleação do bulbo ocular esquerdo, 12 coelhos da raça Nova Zelândia receberam implantes do alfa-TCP-i com 12mm de diâmetro. A avaliação clínica foi realizada diariamente nos primeiros 15 dias e depois a cada quinze dias até o fim do período de estudo. Para análise morfológica, seguiu-se a exenteração de três animais por período experimental (15, 45, 90 e 180 dias). As superfícies externa e interna do implante mostraram-se compactas, sólidas e lisas, com seis canais que se interconectavam centralmente. A microarquitetura caracterizou-se pela formação de colunas de cristais hexagonais. Sinais de infecção, exposição, deiscência de sutura ou extrusão não foram notados em nenhum dos animais durante o período de estudo. A análise morfológica revelou a presença de fina cápsula ao redor do implante de onde surgiram projeções fibrovasculares que o penetraram através dos canais de interconexão. Nos primeiros dias após a inserção das esferas, notou-se intensa reação inflamatória que se mostrou ausente aos 180 dias. O implante do cimento de alfa-fosfato tricálcico foi bem tolerado em coelhos, mostrou-se relativamente inerte e permitiu a infiltração de tecido fibrovascular através dos canais de interconexão.
Sujet(s)
Animaux , Lapins , Malformations oculaires/diagnostic , Malformations oculaires/rééducation et réadaptation , Implantation de prothèse/rééducation et réadaptation , Implantation de prothèse/statistiques et données numériquesRÉSUMÉ
Twenty-five arthrodeses were performed in four cats and 17 dogs using synthetic hydroxyapatite as fresh autogenous graft cancellous bone substitute. Arthrodesis was performed in the carpal joint in eight cases, in the tarsal joint in 10, in the elbow joint in six, and in the knee joint in one case. The mean radiographic follow-up time was 30 days in one animal, 45 days in another animal and 60 days in the 19 remaining cases. Bone union was observed in 24 arthrodeses. Non-union of one elbow arthrodesis was due to failure of stabilization. Restoration of limb functionality was classified as good to excellent in 22 cases. Hydroxyapatite was able to promote bone growth and is suitable for using in routine surgical procedures for small animals
Realizaram-se 25 artrodeses em 21 casos, quatro em gatos e 17 em cães, utilizando hidroxiapatita sintética como substituto ao enxerto ósseo autógeno esponjoso fresco, sendo oito na articulação do carpo, 10 na articulação do tarso, seis na do cotovelo e uma na do joelho. As avaliações radiográficas foram realizadas aos 30 dias em um animal, aos 45 dias em outro e aos 60 dias nos 19 casos restantes. Visibilizou-se união óssea em 24 artrodeses e a não-união em um cotovelo foi atribuída a falha na estabilização. O retorno à função do membro foi classificado de bom a excelente em 22 casos. A hidroxiapatita foi capaz de viabilizar o crescimento ósseo e mostrou-se factível para utilização na prática cirúrgica rotineira em pequenos animais