Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
Ajouter des filtres








Gamme d'année
1.
The Korean Journal of Physiology and Pharmacology ; : 437-442, 2009.
Article Dans Anglais | WPRIM | ID: wpr-727460

Résumé

A non-steroidal anti-inflammatory drug (NSAID) has many adverse effects including cardiovascular (CV) risk. Diclofenac among the nonselective NSAIDs has the highest CV risk such as congestive heart failure, which resulted commonly from the impaired cardiac pumping due to a disrupted excitation-contraction (E-C) coupling. We investigated the effects of diclofenac on the L-type calcium channels which are essential to the E-C coupling at the level of single ventricular myocytes isolated from neonatal rat heart, using the whole-cell voltage-clamp technique. Only diclofenac of three NSAIDs, including naproxen and ibuprofen, significantly reduced inward whole cell currents. At concentrations higher than 3 micrometer, diclofenac inhibited reversibly the Na+ current and did irreversibly the L-type Ca2+ channels-mediated inward current (IC50=12.89+/-0.43 micrometer) in a dose-dependent manner. However, nifedipine, a well-known L-type channel blocker, effectively inhibited the L-type Ca2+ currents but not the Na+ current. Our finding may explain that diclofenac causes the CV risk by the inhibition of L-type Ca2+ channel, leading to the impairment of E-C coupling in cardiac myocytes.


Sujets)
Animaux , Rats , Anti-inflammatoires non stéroïdiens , Canaux calciques de type L , Diclofenac , Coeur , Défaillance cardiaque , Ibuprofène , Cellules musculaires , Myocytes cardiaques , Naproxène , Nifédipine , Techniques de patch-clamp
2.
Journal of Korean Society of Medical Informatics ; : 45-53, 2000.
Article Dans Coréen | WPRIM | ID: wpr-31146

Résumé

In this study, we developed MobileNurseTM; a prototype of mobile nursing information system using PDA. MobileNurseTM is designed to communicate with hospital information system(HIS) via mobile support station(MSS) which interchanges and stores clinical data. MobileNurseTM consists of 3 components. The first component is medical order checking module. It enables nurses to retrieve patients' information such as physicians' orders and test results at anywhere or anytime. The second component is nursing recording module which helps nurses to record the results of their practices at bedside. On the autosynchronization of MSS and PDA, the data in PDA and MSS can be interchanged and updated respectively. The last component is nursing unit care planing module. It is helpful for retrieving the nursing care plans of patients that are expected to be done, such as patients' discharge, consultation, or transfer. With use of PDA in clinical environment, nurses can spend more time on caring for patients by reducing time-consuming, redundant paperwork. It is promising that this 'point-of-care system enables nurses to improve the quality of nursing care.


Sujets)
Humains , Systèmes d'information , Soins infirmiers , Dossiers de soins infirmiers , Soins , Planification des soins du patient
SÉLECTION CITATIONS
Détails de la recherche