Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 5 de 5
Filtre
1.
Rev. méd. Chile ; 135(3): 307-316, mar. 2007. graf, tab
Article Dans Espagnol | LILACS | ID: lil-456616

Résumé

Background: Mechanical ventilation may contribute to lung injury and then enhance systemic inflammation. Optimal ventilatory parameters such as tidal volume (V T) and positive end expiratory pressure (PEEP) can be determined using different methods. Low flow pressure volume (P/V-LF) curve is a useful tool to assess the respiratory system mechanics and set ventilatory parameters. Aim: To set V T and PEEP according P/V-LF curve analysis and evaluate its effects on gas exchange and hemodynamic parameters. Materials and methods: Twenty seven patients underwent P/V-LF within the first 72 hours of acute lung injury/acute respiratory distress syndrome (ALI/ARDS). P/V-LF curves were obtained from the ventilator and both lower and upper inflexion points determined. Gas exchange and hemodynamic parameters were measured before and after modifying ventilator settings guided by P/V-LF curves. Results: Ventilatory parameters set according P/V-LF curve, led to a rise of PEEP and reduction of V T: 11.6±2.8 to 14.1±2.1 cm H2O, and 9.7±2.4 to 8.8±2.2 mL/kg (p <0.01). Arterial to inspired oxygen fraction ratio increased from 158.0±66 to 188.5±68.5 (p <0.01), and oxygenation index was reduced, 13.7±8.2 to 12.3±7.2 (p <0.05). Cardiac output and oxygen delivery index (IDO2) were not modified. Demographic data, gas exchange improvement and respiratory system mechanics showed no significant difference between patients with extra-pulmonary and pulmonary ALI/ARDS. There was no evidence of significant adverse events related with this technique. Conclusion: P/V-LF curves information allowed us to adjust ventilatory parameters and optimize gas exchange without detrimental effects on oxygen delivery in mechanically ventilated ALI/ARDS patients.


Sujets)
Femelle , Humains , Mâle , Adulte d'âge moyen , Hémodynamique/physiologie , Ventilation à pression positive , Ventilation artificielle/normes , /physiopathologie , Gazométrie sanguine , Études prospectives , Normes de référence , Ventilation artificielle/effets indésirables , /sang , /étiologie , Volume courant/physiologie
2.
Rev. méd. Chile ; 133(7): 817-822, jul. 2005. ilus, tab
Article Dans Espagnol | LILACS | ID: lil-429142

Résumé

A subgroup of patients infected with the Hantavirus develops a pulmonary syndrome (HPS) characterized by severe acute respiratory failure and myocardial depression, that has a high mortality rate. Extracorporeal life support (ECLS) could be a valuable therapeutic tool in such patients. We report a 24 years old male with HPS that was successfully managed when an arterio-venous shunt was added to a conventional veno-arterial ECLS technique. Precise criteria have been developed to predict which patients should be considered for this treatment.


Sujets)
Adulte , Humains , Mâle , Anastomose chirurgicale artérioveineuse/méthodes , Oxygénation extracorporelle sur oxygénateur à membrane/méthodes , Syndrome pulmonaire à hantavirus/thérapie , Artère pulmonaire/chirurgie , Anastomose chirurgicale artérioveineuse/instrumentation , Oxygénation extracorporelle sur oxygénateur à membrane/instrumentation
3.
Rev. méd. Chile ; 133(6): 625-631, jun. 2005. tab, graf
Article Dans Espagnol | LILACS | ID: lil-429114

Résumé

Background:Monitoring of cardiac preload by determination of pulmonary artery occlusion pressure (PAOP) has been traditionally used to guide fluid therapy to optimize cardiac output (CO). Since factors such as intrathoracic pressure and ventricular compliance may modify PAOP, volumetric estimators of preload have been developed. The PiCCO system is able to measure CO and intrathoracic blood volume (ITBV) by transpulmonary thermodilution. Aim: To compare a volumetric (ITBV) versus a pressure (PAOP) determination to accurately estimate cardiac preload in severely ill patients. Patients and Methods: From June 2001 to October 2003, 22 mechanically ventilated patients with hemodynamic instability underwent hemodynamic monitoring with pulmonary artery catheter (PAC) and PiCCO system. ITBV index (ITBVI), PAOP and CI were measured simultaneously by both methods. One hundred thirty eight deltas (D) were obtained from the difference of ITBVI, PAOP, CI-PAC and CI-PiCCO between 6-12 am and 6-12 pm. Linear regression analysis of DITBVI versus Ð CI-PiCCO and Ð PAOP versus DCI-PAC were made. Results: Mean age of patients was 60.8 ± 19.4 years. APACHE II was 23.9 ± 7. Fifteen patients met criteria for acute respiratory distress syndrome (ARDS). Delta ITBVI significantly correlated with DCI-PiCCO (r=0.54; 95% confidence interval = 0.41-0.65; p <0.01). There was no correlation between DPAOP and Ð CI-PAC. Conclusion: ITBVI correlated better with CI than PAOP, and therefore it seems to be a more accurate estimator of preload in unstable, mechanically ventilated patients.


Sujets)
Adulte , Femelle , Humains , Mâle , Adulte d'âge moyen , Volume sanguin/physiologie , Débit cardiaque/physiologie , Maladie grave , Monitorage physiologique/méthodes , Pression artérielle pulmonaire d'occlusion/physiologie , Hémodynamique/physiologie , Études prospectives , Débit systolique/physiologie
4.
Rev. méd. Chile ; 130(6): 677-680, jun. 2002. tab, graf
Article Dans Espagnol | LILACS | ID: lil-317501

Résumé

Hemolytic-uremic syndrome (HUS) is an uncommon complication of pneumococcal infection. Highly suggesting findings in a patient with Streptococcus pneumoniae infection are: microangyopatic hemolytic anemia, thrombocytopenia and acute renal failure. We report a 41 years old woman, admitted to the hospital due to a severe pneumonia, that required the surgical drainage of an empyema. On admission, a drop in packed red cell volume from 41 to 25 percent, the presence of schistocytes in the blood smear, an elevation of LDH to 1,700 IU/L, a fall in haptoglobin to 5.8 mg/dL and a thrombocytopenia of 72,000 per mm3 were detected. These alterations coincided with an oliguric acute renal failure. She was treated with hemodialysis and the hemolytic syndrome was managed with plasmapheresis. She was discharged 35 days after admission and in the follow up, after 2.5 months, her serum creatinine is 1.2 mg/dL and her packed red cell volume is 41 percent


Sujets)
Humains , Adulte , Femelle , Streptococcus pneumoniae , Pneumonie à pneumocoques/complications , Pleuropneumonie/complications , Syndrome hémolytique et urémique/étiologie , Streptococcus pneumoniae , Insuffisance rénale , Dialyse rénale , Pneumonie à pneumocoques/traitement médicamenteux , Plasmaphérèse , Pleuropneumonie/traitement médicamenteux , Syndrome hémolytique et urémique/thérapie
5.
Rev. chil. med. intensiv ; 17(1): 15-19, mar. 2002. ilus, graf
Article Dans Espagnol | LILACS | ID: lil-340291

Résumé

Traditionally Pulmonary wedge pressure (PWP) determination with Swan-Ganz catheter has been the gold standard to estimate ventricular preload in critically ill patients. However, the correlation between PWP and left ventricular telediastolic volume is poor, and the tecnique does not allow any estimation of extravascular lung water (EVLW). In the last years, several techniques have been developed to improve assessment of intra and extravascular volumes. Two tracers transcardiopulmonary dilution method was developed by Pearce et al in the early 60ïs. It used a thermal tracer to estimate intrathoracic total volumen (ITTV), and a colorimetric tracer for estimting intrathoracic blood volume (ITBV). The difference between ITTV and ITBV is called EVLW. Recently, the technique has been simplified to use just the thermal tracer. The Pulse Contour Cardiac Output computer (PiCCO, Pulsion Medizintechnik, Germany), allows a continous measurement of cardiac output and an intermittent measurement of ITTV, ITBV and EVLW. The use of this new technique could improve patient management, allowing optimal fluids administration without producing lung edema. Besides the PiCCO computer, both a standard central venous line in an upper body vein and a specially designed femoral artery line to measure thermal tracer dissipation are required. Preliminary experience has shown that it is a reliable method, with low morbidity and easy implementation, and may be a promising and useful tool in critical care patients


Sujets)
Humains , Eau extravasculaire pulmonaire , Volume sanguin/physiologie , Pression sanguine , Débit cardiaque , Cathétérisme par sonde de Swan-Ganz , Thermodilution/méthodes
SÉLECTION CITATIONS
Détails de la recherche