Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
1.
Indian J Cancer ; 2014 Jul-Sep; 51(3): 366-368
Article Dans Anglais | IMSEAR | ID: sea-154421

Résumé

Treatment of cancer is limited by affordability of patients in the many developing countries including India. Generic drug manufacturers have responded to this scenario by making drugs available at affordable costs, often at less than 10% the cost of the original brand. In our practice, it is found that there is a three-fold higher prescription of generic brands compared to innovator, accompanied by cost savings of up to 80% per prescription. Unfortunately, the regulatory environment prevailing in India is not geared to ensure satisfactory quality of generic products. The standards set by the regulatory agencies for establishing equivalence of generics vis-ΰ-vis the innovator product allow anticancer generics to enter markets without undergoing clinical evaluation. Many drug manufacturing units in India flout good manufacturing practice norms, which was evident during the center for drug evaluation and research classifications inspection in the year 2006. Inferior drugs have therefore, made their way into the Indian markets, compromising the quality of care. The system of drug manufacturing and marketing approval needs a major overhaul, including regular inspection of manufacturing facilities. Bioequivalence should be made mandatory for all oral formulations. Unless these measures are rigidly implemented, the benefits of generic substitution would be seriously undermined.


Sujets)
Antinéoplasiques/usage thérapeutique , Médicaments génériques/usage thérapeutique , Humains , Inde , Tumeurs/traitement médicamenteux , Équivalence thérapeutique
2.
Indian J Cancer ; 2009 Jul-Sept; 46(3): 237-239
Article Dans Anglais | IMSEAR | ID: sea-144246

Résumé

Occurrence of primary Hodgkin's lymphoma (PHL) of the liver is extremely rare. We report on a case of a 60-year-old male who presented with liver mass and B-symptomatology. Hepatoma or hepatic metastasis from a gastrointestinal primary was initially suspected. Tumor markers like AFP, CEA, Total PSA, and CA-19.9 were within normal limits. Positron Emission Tomography / Computerized Tomography (PET/CT) revealed a large hepatic lesion and a nodal mass in the porta hepatis. A liver biopsy was consistent with Hodgkin's lymphoma. There was complete regression of the hepatic lesion and evidence of shrinkage of the nodal mass following four cycles of chemotherapy. 18F Fluro -de-oxy Glucose (FDG) PET / CT in this case helped in establishing a primary hepatic lymphoma by demonstrating the absence of pathologically hypermetabolic foci in any other nodes or organs. PET / CT scan is a useful adjunct to conventional imaging and histopathology, not only to establish the initial diagnosis, but also to monitor treatment response in PHL.


Sujets)
Protocoles de polychimiothérapie antinéoplasique/usage thérapeutique , Fluorodésoxyglucose F18/diagnostic , Maladie de Hodgkin/traitement médicamenteux , Maladie de Hodgkin/anatomopathologie , Humains , Tumeurs du foie/traitement médicamenteux , Tumeurs du foie/anatomopathologie , Mâle , Adulte d'âge moyen , Tomographie par émission de positons , Pronostic , Radiopharmaceutiques/diagnostic , Tomodensitométrie
SÉLECTION CITATIONS
Détails de la recherche