Radiation Oncology Journal ; : 127-133, 2019.
Article Dans Anglais | WPRIM | ID: wpr-760998

Résumé

PURPOSE: The aim of this study was to identify volume changes and dose variations of rectum and bladder during radiation therapy in prostate cancer (PC) patients. MATERIALS AND METHODS: We analyzed 20 patients with PC treated with helical tomotherapy. Daily image guidance was performed. We re-contoured the entire bladder and rectum including its contents as well as the organ walls on megavoltage computed tomography once a week. Dose variations were analyzed by means of Dmedian, Dmean, Dmax, V₁₀ to V₇₅, as well as the organs at risk (OAR) volume. Further, we investigated the correlation between volume changes and changes in Dmean of OAR.


Sujets)
Humains , Organes à risque , Prostate , Tumeurs de la prostate , Radiothérapie guidée par l'image , Radiothérapie conformationnelle avec modulation d'intensité , Rectum , Vessie urinaire