Chinese Journal of Preventive Medicine ; (12): 125-127, 2003.
Article Dans Chinois | WPRIM | ID: wpr-257216

Résumé

<p><b>OBJECTIVE</b>To use a new kind of fixing material, i.e. Sol-Gel organic-inorganic hybridized material to immobilize bacterium to detect Biochemical oxygen demand quickly.</p><p><b>METHODS</b>The biosensor was fabricated using a thin film in which Hansenula anomala was immobilized by sol-gel and an oxygen electrode. The optimum measurement for biochemical oxygen demand was at pH 7.0; 28 degrees C; response time 3 - 12 min. Pure organic compound, sewage and rate of recovery were detected with the biosensor.</p><p><b>RESULTS</b>It shows that the BOD biosensor can be used to detect many organic compounds such as amino acid, glucide. It is suitable to monitor sewage and industrial waste water which has low level alcohols and phenols. The microbial membrane can work 3 months and remain its 70% activity. It is measured that the rate of recovery of BOD is between 90% to 105% in sewage.</p><p><b>CONCLUSION</b>The study confirmed the effectiveness and usefulness of BOD sensor, which is quick, convenient, low cost and reliable with little interference.</p>


Sujets)
Bactéries , Techniques de biocapteur , Cellules immobilisées , Gels , Membrane artificielle , Nylons , Oxygène , Eaux d'égout , Microbiologie