Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 5 de 5
Filtre
Ajouter des filtres








Gamme d'année
1.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 269-275, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1013507

Résumé

@#Objective To summarize and analyze the preliminary clinical outcomes of the KokaclipTM transcatheter edge-to-edge mitral valve repair system for severe degenerative mitral regurgitation (DMR). Methods This study was a single-arm, prospective, single-group target value clinical trial that enrolled patients who underwent the KokaclipTM transcatheter edge-to-edge repair (TEER) system for DMR in the Department of Heart Surgery of Guangdong Provincial People's Hospital, Guangdong Cardiovascular Institute from June 2022 to January 2023. Differences in the grade of mitral regurgitation (MR) during the perioperative and follow-up periods were compared, and the incidences of adverse events such as all-cause death, thoracotomy conversion, reoperation, and severe recurrence of MR during the study period were investigated. Results The enrolled patient population consisted of 14 (50.0%) females with a mean age of 70.9±5.4 years. Twenty-eight (100.0%) patients were preoperatively diagnosed with typeⅡ DMR, with a prolapse width of 12.5 (11.0, 16.1) mm, a degree of regurgitation 4+ leading to pulmonary venous reflux, and a New York Heart Association cardiac function class≥Ⅲ. All patients completed the TEER procedure successfully, with immediate postoperative improvement of MR to 0, 1+, and 2+ grade in 2 (7.1%), 21 (75.0%), and 5 (17.9%) patients, respectively. Mitral valve gradient was 2.5 (2.0, 3.0) mm Hg. Deaths, thoracotomy conversion, or device complications such as unileaflet clamping, clip dislodgement, or leaflet injury were negative. Twenty-eight (100.0%) patients completed at least 3-month postoperative follow-up with a median follow-up time of 5.9 (3.6, 6.8) months, during which patients had a mean MR grade of 1.0+ (1.0+, 2.0+) grade and a significant improvement from preoperative values (P<0.001). There was no recurrence of ≥3+ regurgitation, pulmonary venous reflux, reoperation, new-onset mitral stenosis, or major adverse cardiovascular events. Twenty-two (78.6%) patients’ cardiac function improved to classⅠorⅡ. Conclusion The domestic KokaclipTM TEER system has shown excellent preliminary clinical results in selected DMR patients with a high safety profile and significant improvement in MR. Additional large sample volume, prospective, multicenter studies, and long-term follow-up are expected to validate the effectiveness of this system in the future.

2.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 214-220, 2023.
Article Dans Chinois | WPRIM | ID: wpr-965729

Résumé

@#Objective     To evaluate the early clinical outcomes of the Renatus® balloon-expandable valve in the treatment of severe aortic stenosis. Methods    From November 2021 to April 2022, a total of 38 patients who received Renatus® balloon-expandable valve for severe aortic stenosis in Guangdong Provincial People's Hospital were included. There were 22 males and 16 females, with an average age of 73.7±5.3 years. Mean aortic gradient and peak aortic jet velocity at baseline, post-procedure, and follow-up were compared. Clinical outcomes including all-cause mortality, perivalvular leakage, serious adverse cardiovascular events and the occurrence of permanent pacemaker implantation were assessed. Results    All patients completed the procedure successfully without conversion to thoracotomy or perioperative death. The post-implant mean aortic pressure gradient was decreased from 41.5 (27.8, 58.8) mm Hg to 6.0 (3.0, 8.0) mm Hg, and the peak aortic jet velocity was also decreased from 4.1±0.9 m/s to 1.7±0.4 m/s (P<0.001). Pacemakers were required in 2 (5.3%) patients. The median follow-up time was 27.5 (23.0, 87.5) d, with a follow-up rate of 100.0%. The mean aortic gradient was 8.0 (7.0, 10.8) mm Hg and peak aortic jet velocity was 2.0±0.3 m/s, showing significant improvement compared with those in the preoperative period (P<0.001). No severe aortic regurgitation or paravalvular leak was observed. There was no serious cardiovascular adverse event or reoperative event during the study period. Conclusion    Transcatheter aortic valve replacement with the domestic Renatus® balloon-expandable valve system is a safe and effective procedure for selected patients with severe aortic stenosis who are at high risk or not candidates for surgical aortic valve replacement.

3.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 516-519, 2018.
Article Dans Chinois | WPRIM | ID: wpr-806800

Résumé

Objective@#To study the correlation of occupation musculoskeletal disease (OMD) and safety behavior in assembly line workers.@*Methods@#Selected assembly line workers of 3 manufacturing factory in Pacity as the objects of this study by judgement sampling. Questionnaires were used for messages collection including the general sociodemographic characteristic, OMD condition, occupational safety behaviors.@*Results@#This study shows that, 826 OMD workers were found that the annual prevalence was 38.03%. The scores of work posture, handling habits, health habit in OMD group was lower than non-OMD group (P<0.01) but personal protection behavior was higher than non-OMD group (P<0.01) . Test of binary logistic regression revealed that age, workage, work posture, handling habits were the factors of OMD (P<0.01) .@*Conclusion@#Safety behaviors were the potent factors of OMD that work posture and handling habits should be broadcast.

4.
China Occupational Medicine ; (6): 459-462, 2017.
Article Dans Chinois | WPRIM | ID: wpr-881632

Résumé

OBJECTIVE: To investigate the prevalence of occupational musculoskeletal disorders(OMD) in workers of manufacturing industry,and to analyze its influencing factors.METHODS: A total of 1 168 first-line workers from 3manufacturing enterprises were selected as study subjects using convenient sampling.The self-designed questionnaire was used to investigate the basic information and the ergonomics of work process.The Nordic Musculoskeletal Questionnaire was used to investigate the prevalence of OMD.The workers were divided into non-OMD group and OMD group.RESULTS: The prevalence of OMD in these 1 168 workers was 34.9%.Comparing with the non-OMD group,the score of using auxiliary tools to carry the weights in the OMD group was higher(P<0.01),and the scores of straight waist and bent knees when transporting heavy object was lower(P<0.01).Logistic regression analysis showed that male workers had a higher risk of OMD than female workers(P<0.05).The longer the length of service,the greater the risk of OMD(P<0.01).Shift workers had the higher risk of OMD than non-shift workers(P<0.01).The higher scores of using auxiliary tools to carry the weights and straight waist and bent knees when transporting heavy object(it mean that less use of the above labor behavior and posture),the greater the risk of OMD(P<0.05).CONCLUSION: Sex,length of service,shift,labor behavior and posture are the influencing factors of OMD.

5.
China Occupational Medicine ; (6): 164-175, 2017.
Article Dans Chinois | WPRIM | ID: wpr-881592

Résumé

OBJECTIVE: To explore the effect of 1,2-dichloroethane(1,2-DCE) induced apoptosis on the expression of related proteins in human neuroblastoma cells(SH-SY5 Y cells). METHODS: SH-SY5 Y cells were cultured in complete medium with 1,2-DCE at final concentrations of 0,10,20,30,40,50,60,70 and 80 mmol/L. After being cultured for24 hours,the apoptosis of SH-SY5 Y cells was tested by flow cytometry using annexin Ⅴ-fluorescein isothiocyanate and propidium iodide. Western blot was used to detect the protein expression of P53,B cell lymphoma/leukmia-2(BCL-2)and BCL-2 associated X protein(BAX). RESULTS: At 1,2-DCE concentrations of 0-80 mmol/L,the total apoptosis rate of SH-SY5 Y cells increased with 1,2-DCE concentrations in a dose-dependent manner(P < 0. 01). At 1,2-DCE concentrations of 30-80 mmol/L,the early apoptosis rate and total apoptosis rate of SH-SY5 Y cells increased significantly than the control group(P < 0. 05). Compared with the other groups,the protein expression of P53 was the lowest when the1,2-DCE concentration was 20 mmol/L(P < 0. 05),and the protein expression of BCL-2 and the BCL-2/BAX ratio were the lowest when the 1,2-DCE concentration was 70 mmol/L(P < 0. 05). There is no dose-response relationship in the1,2-DCE concentrations and the protein expression levels of P53,BCL-2 and BAX,and BCL-2/BAX ratio. Linear multiple regression analysis revealed that the total apoptosis rate of SH-SY5 Y cells treated with 1,2-DCE was associated with the protein expression of P53 and BCL-2,and BCL-2/BAX ratio(P < 0. 05). CONCLUSION: 1,2-DCE could inhibit the apoptosis of SH-SY5 Y cells. The mechanisms may be related to the changes of P53 and BCL-2 protein expression,and BCL-2/BAX relative amount.

SÉLECTION CITATIONS
Détails de la recherche