Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
Ajouter des filtres








Gamme d'année
1.
Chinese Journal of Blood Transfusion ; (12): 1296-1299, 2021.
Article Dans Chinois | WPRIM | ID: wpr-1003965

Résumé

【Objective】 To develop an assay to determine β-lactam antibiotics using microcolumn gels and to study the β-lactam antibiotics present in the blood of patients and their clinical significances. 【Methods】 446 patients with a history of taking β-lactam antibiotics from January 2019 to June 2019 were randomly selected from Trauma Emergency Center, Department of Arthrosis, Department of Spine and Department of Bone Oncology of our hospital, and 4 mL(per capita) venous blood was collected. Irregular antibody screening, anti-globulin detection and drug antibody determination were performed by microcolumn gel method. The data of gender, age, disease, blood transfusion history and medication were collected. The test results and clinical data were retrospective analyzed. 【Results】 The yielding rate of antibody was 0.45%(2/446) in patients with a history of taking β -lactam antibiotics. 16.38%(73/446) of the samples were positive in direct antiglobulin test, and 64.38%(47/73) of them did not agglutinate with RBCs treated with drugs. The yielding rate of specific antibodies against drug was 4.93%(22/446), and the titer ranged from 2 to 128(8). 1 case of auto-IgM antibody, 1 case of blood group related antibody and 2 cases of non-specific protein adsorption were detected. The yielding rate of drug antibody in patients with blood transfusion history reached to 12.10 %(22/124), so it was also high in patients with bone tumor. 【Conclusion】 Direct antiglobulin assay is helpful for the detection of β-lactam antibodies. The negative results of antibody screening cannot completely exclude the presence of drug antibodies. The yielding rate of drug antibody can be greatly improved by specific drug antibody detection, and it was higher in transfused patients relative to non-transfused one.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 624-628, 2019.
Article Dans Chinois | WPRIM | ID: wpr-755020

Résumé

Objective To study the method of dose reconstruction in human body under the photon external radiation accident condition,and to verify the accuracy of the method for the local dose distribution.Methods Based on the open source Monte Carlo tool kit Geant 4 and using the human voxel phantom recommended by ICRP Publication 103,the dose reconstruction method under the condition of external radiation accident was studied to evaluate the average absorbed dose,organ absorbed dose and local dose distribution.To validate the code,several irradiation experiments were implemented in some standard radiation fields by putting TLDs in the tissue equivalent physical phantom ART.A voxel phantom was used to reconstruct the radiation doses,which was created based on the CT scan image of the ART phantom with resolution of 1.57 mm× 1.57 mm× 10.00 mm.The result of experiment were compared with those of dose reconstruction simulation.Results The relative uncertainty of the measured values was 10.9%.The relative uncertainty of the dose reconstruction simulation values was 7.10% at the non-tissueinterface area and 16.6% at the tissue-interface area.For 451 measuring points,the average of the simulated value divided by the measured value was 0.972,with the standard deviation of 0.083 8.In the range of 0.95-1.05,0.90-1.10 and 0.80-1.20,and the proportions were 49.2%,79.4% and 96.4%,respectively.Conclusions The method of Monte Carlo dose reconstruction based on human voxel phantom meets the accuracy requirement of actual uses both at the whole body or organ level and at the local dose distribution level.It can be used as a powerful tool for dose assessment of the exposed people in an external radiation accidents and provide support for diagnosis and treatment.

SÉLECTION CITATIONS
Détails de la recherche