1.
Journal of the Korean Fracture Society ; : 111-117, 2023.
Article Dans Anglais | WPRIM | ID: wpr-1001673

Résumé

Purpose@#This study evaluates the radiation shielding performance of a new lead-free tungsten-based sheet to reduce the radiation exposure of operators and patients under C-arm fluoroscopy. @*Materials and Methods@#A non-lead radiation shielding sheet (ROO201128; Pentas, Korea) was fabri-cated using tungsten and bismuth. The dose measurements were conducted using a C-arm fluoroscopy machine at 64 kVp and 1.5 mA, assuming two possible scenarios according to the position of the sheet. In each scenario, measurements were conducted at three distances (30, 60, and 90 cm) away from the beam center and in three directions (cephal, caudal, and operator’s direction). @*Results@#In the area within a radius of 60 cm from the beam center, the measured doses were reduced by 66.3% on mean, and the doses measured at distances more than 60 cm were less than 0.1 mSv/h in both scenarios. The most beneficial utilization of the lead-free shielding sheet was verified during C-arm fluoroscopy by placing the sheet on the X-ray tube. The operator’s radiation exposure was reduced by 56.6% when the sheet was placed under the phantom, and by 81.0% when the sheet was placed on the X-ray tube. @*Conclusion@#The use of lead-free radiation shielding sheets under C-arm fluoroscopy was effective in reducing radiation exposure, and the most beneficial scenario in which the sheet can be utilized was verified when the sheet was placed on the X-ray tube.

2.
Radiation Oncology Journal ; : 297-303, 2021.
Article Dans Anglais | WPRIM | ID: wpr-918756

Résumé

Purpose@#To evaluate the prognostic value of the pretreatment maximum standardized uptake value (SUVmax) for locoregional control (LRC) of early glottic cancer treated with primary radiotherapy. @*Materials and Methods@#We retrospectively reviewed the medical records of 101 patients with T1-T2N0 glottic cancer treated with helical tomotherapy between 2013 and 2016. The clinical T-stages were T1 in 87 (86.1%) and T2 in 14 (13.9%) patients. The median total dose was 63 Gy (63–67.5 Gy) in 2.25 Gy per fraction. The survival outcomes were plotted using Kaplan-Meier curves. Receiver operating characteristic curves were used to assess the optimal SUVmax cut-off value for predicting locoregional recurrence. @*Results@#The median follow-up period was 58 months (range, 11 to 90 months). The 5-year overall survival (OS) and locoregional recurrence-free survival rates were 96.8% and 85.4%, respectively. The median pretreatment SUVmax of the primary tumor for all 101 patients was 2.3 (range, 1.1 to 9.1). The best cut-off value for SUVmax for predicting LRC was 3.3, with a sensitivity of 78.6% and specificity of 73.6%. Univariate analysis showed that T-stage, overall treatment time (≥43 days), and high SUVmax (≥3.3) were significant predictors of LRC. Multivariate analysis showed that LRC was independently affected by a high SUVmax (≥3.3) (hazard ratio = 5.505, p = 0.020). @*Conclusion@#High pretreatment SUVmax (≥3.3) is a negative prognostic factor for LRC in early glottic cancer patients treated with primary radiotherapy.

3.
Journal of the Korean Radiological Society ; : 1477-1492, 2021.
Article Dans Anglais | WPRIM | ID: wpr-916863

Résumé

Purpose@#Dedicated breast CT is an emerging volumetric X-ray imaging modality for diagnosis that does not require any painful breast compression. To improve the detection rate of weakly enhanced lesions, an adaptive image rescaling (AIR) technique was proposed. @*Materials and Methods@#Two disks containing five identical holes and five holes of different diameters were scanned using 60/100 kVp to obtain single-energy CT (SECT), dual-energy CT (DECT), and AIR images. A piece of pork was also scanned as a subclinical trial. The image quality was evaluated using image contrast and contrast-to-noise ratio (CNR). The difference of imaging performances was confirmed using student’s t test. @*Results@#Total mean image contrast of AIR (0.70) reached 74.5% of that of DECT (0.94) and was higher than that of SECT (0.22) by 318.2%. Total mean CNR of AIR (5.08) was 35.5% of that of SECT (14.30) and was higher than that of DECT (2.28) by 222.8%. A similar trend was observed in the subclinical study. @*Conclusion@#The results demonstrated superior image contrast of AIR over SECT, and its higher overall image quality compared to DECT with half the exposure. Therefore, AIR seems to have the potential to improve the detectability of lesions with dedicated breast CT.

4.
Radiation Oncology Journal ; : 147-152, 2018.
Article Dans Anglais | WPRIM | ID: wpr-741938

Résumé

PURPOSE: To evaluate the treatment outcomes of adjuvant external beam radiation therapy (EBRT) and vaginal brachytherapy (VB) following radical hysterectomy in cervical cancer patients with involved vaginal resection margin (VRM). MATERIALS AND METHODS: We retrospectively reviewed the medical records of 21 patients treated with postoperative EBRT and VB for positive VRM FIGO stage IB–IIA cervical cancer between 2003 and 2015. Concurrent platinum-based chemotherapy was administered to all patients. RESULTS: The median whole pelvis EBRT dose was 50.4 Gy (range, 45 to 50.4 Gy). In the VB, the median dose per fraction, number of fractions, and total dose delivered were: 4 Gy (range, 3.0 to 4.0 Gy), 4 fractions (range, 3 to 5 fractions), and 16 Gy (range, 12 to 20 Gy), respectively. At a median follow-up of 46 months (range, 9 to 122 months), local recurrence was observed in 2 patients, and distant metastasis was present in 7 patients. All patients with local recurrence subsequently developed distant metastases. The 5-year local control, disease-free survival, and overall survival rates were 89.1%, 65.9%, and 62.9%, respectively. Of the 21 patients, 7 patients (33.3%) reported grade 2 acute toxicity; however, there were no grade 3 or higher acute adverse events. Grade 1–2 late toxicities were observed in 8 patients. Late grade 3 urinary toxicity was reported in 1 patient. CONCLUSIONS: Adjuvant EBRT and VB showed excellent local control and low toxicity in cervical cancer patients with positive VRM. Although limited by its retrospective nature, the findings from our study provide evidence supporting the use of additional VB in pathologically involved VRM.


Sujets)
Humains , Curiethérapie , Survie sans rechute , Traitement médicamenteux , Études de suivi , Hystérectomie , Dossiers médicaux , Métastase tumorale , Pelvis , Récidive , Études rétrospectives , Taux de survie , Tumeurs du col de l'utérus
5.
Radiation Oncology Journal ; : 185-188, 2017.
Article Dans Anglais | WPRIM | ID: wpr-44433

Résumé

Primary liver tumor, especially hepatocellular carcinoma (HCC), is a common cause of cancer death worldwide. The incidence is generally higher in Asian countries than in western countries. Carcinogenesis of HCC is often associated with hepatitis viral infections. Current standard treatment of HCC is surgical resection or transplantation in patients with early stage disease. However, the patient with advanced stage disease, surgical resection is often limited. Sorafenib or other treatment modalities are not so effective as well. We report a case of unusual radiation super-sensitivity in advanced stage HCC, and review the literature.


Sujets)
Humains , Asiatiques , Carcinogenèse , Carcinome hépatocellulaire , Hépatite , Incidence , Foie , Radiothérapie
6.
Journal of Korean Medical Science ; : 757-763, 2017.
Article Dans Anglais | WPRIM | ID: wpr-25087

Résumé

The kidney is one of the most radiosensitive organs in the abdominal cavity and is the dose-limiting structure in cancer patients receiving abdominal or total body irradiation. In the present study, the effect of coenzyme Q10 (CoQ10) on radiation nephropathy was evaluated in rats. A total of 72 rats were equally randomized into 4 groups: Control, CoQ10, irradiation with 10 Gy (RT) + placebo, or RT + CoQ10. The 2 RT groups received single 10 Gy of abdominal irradiation. The 2 CoQ10 groups were supplemented daily with 1 mL of soybean oil containing 10 mg/kg of CoQ10. The RT + placebo and control groups received same dose of soybean oil. After 24 weeks, laboratory and histopathologic findings were compared. The 2 RT groups showed significant increases in blood urea nitrogen (BUN) and creatinine levels and significant pathologic changes such as glomerulosclerosis and tubulointerstitial fibrosis. CoQ10 supplementation resulted in significant reductions of BUN and creatinine levels compared with the RT + placebo group (P < 0.001 and P = 0.038, respectively). CoQ10 treatment significantly attenuated glomerular and tubular changes of irradiated kidney in semiquantitative analysis (P < 0.001 for both). Administration of CoQ10 can alleviate the radiation-induced nephropathy.


Sujets)
Animaux , Humains , Rats , Cavité abdominale , Azote uréique sanguin , Créatinine , Fibrose , Rein , Huile de soja , Irradiation corporelle totale
7.
Korean Journal of Medical Physics ; : 131-139, 2011.
Article Dans Coréen | WPRIM | ID: wpr-99720

Résumé

A method to get a size of the radiation isocenter of linear accelerators using star-shot images was presented and a computer program was developed to automate the method. Accuracy of the method was verified. The developed program was used to measure sizes of the radiation isocenters for a Clinac 21EX (Varian, USA) using data of quality assurance (QA) performed from June 2008 to December 2010. To calculated the size of radiation isocenter, positions of two points on each central ray of the star-shot image were found and the equation of the central ray was determined using the positions of two points. Using the equations of central rays the radius of the minimum circle intersecting all the central rays, which is one half of the size of radiation isocenter, was calculated. The program measured X-intercepts and y-intercepts of the central rays within errors of 0.084 mm and sizes of radiation isocenters within 0.053 mm. All the errors were less than the spatial resolution of star-shot images 0.085 mm. The radiation isocenter sizes of Clinac 21EX were 0.33+/-0.27 mm, 0.71+/-0.36 mm, 0.50+/-0.16 mm for collimator, gantry and couch respectively. During the measurement period all the measured sizes were less than 2.0 mm and within tolerance. The developed program could calculate the size of radiation isocenters and it would be helpful to routine QA.


Sujets)
Accélérateurs de particules , Radius , Logiciel
8.
Korean Journal of Medical Physics ; : 340-347, 2010.
Article Dans Coréen | WPRIM | ID: wpr-8222

Résumé

DQA, a patient specific quality assurance in tomotherapy, is usually performed using an ion chamber and a film. The result of DQA is analysed with the treatment planning system called Tomo Planning Station (TomoPS). The two-dimensional dose distribution of film measurement is compared with the dose distribution calculated by TomoPS using the gamma-index analysis. In gamma-index analysis, the criteria such as 3%/3 mm is used and we verify that whether the rate of number of points which pass the criteria (pass rate) is within tolerance. TomoPS does not provide any quantitative information regarding the pass rate. In this work, a method to get the pass rate of the gamma-index analysis was suggested and a software PassRT which calculates the pass rate was developed. The results of patient specific QA of the intensity modulated radiation therapy measured with I'mRT MatriXX (IBA Dosimetry, Germany) and DQA of tomotherapy measured with film were used to verify the proposed method. The pass rate was calculated using PassRT and compared with the pass rate calculated by OmniPro I'mRT (IBA Dosimetry, Germany). The average difference between the two pass rates was 0.00% for the MatriXX measurement. The standard deviation and the maximum difference were 0.02% and 0.02%, respectively. For the film measurement, average difference, standard deviation and maximum difference were 0.00%, 0.02% and 0.02%, respectively. For regions of interest smaller than 24.3x16.6 cm2 the proposed method can be used to calculate the pass rate of the gamma index analysis to one decimal place and will be helpful for the more accurate DQA in tomotherapy.


Sujets)
Humains , Hypogonadisme , Maladies mitochondriales , Ophtalmoplégie
9.
Korean Journal of Medical Physics ; : 178-185, 2008.
Article Dans Coréen | WPRIM | ID: wpr-168543

Résumé

Living donor liver transplantation is increasingly performed as an alternative to cadaveric transplantation. Preoperative screening of the donor candidates is very important. The quality, size, and vascular and biliary anatomy of the liver are best assessed with magnetic resonance (MR) imaging or computed tomography (CT). In particular, the volume of the potential graft must be measured to ensure sufficient liver function after surgery. Preoperative liver segmentation has proved useful for measuring the graft volume before living donor liver transplantations in previous studies. In these studies, the liver segments were manually delineated on each image section. The delineated areas were multiplied by the section thickness to obtain volumes and summed to obtain the total volume of the liver segments. This process is tedious and time consuming. To compensate for this problem, automatic segmentation techniques have been proposed with multiplanar CT images. These methods involve the use of sequences of thresholding, morphologic operations (ie, mathematic operations, such as image dilation, erosion, opening, and closing, that are based on shape), and 3D region growing methods. These techniques are complex but require a few computation times. We made a phantom for volume measurement with pig and evaluated actual volume of spleen and liver of phantom. The results represent that our semiautomatic volume measurement algorithm shows a good accuracy and repeatability with actual volume of phantom and possibility for clinical use to assist physician as a measuring tool.


Sujets)
Animaux , Humains , Cadavre , Saccharose alimentaire , Foie , Transplantation hépatique , Donneur vivant , Spectroscopie par résonance magnétique , Dépistage de masse , Mathématiques , Rate , Donneurs de tissus , Transplants
10.
Genomics & Informatics ; : 113-117, 2007.
Article Dans Anglais | WPRIM | ID: wpr-86065

Résumé

The development of microarray technology has facilitated the understanding of gene expression profiles. Despite its convenience, the cause of dye-bias that confounds data interpretation in dual-color DNA microarray experiments is not well known. In order to economize time and money, it is necessary to identify the cause of dye bias, since designing dye-swaps to reduce the dye-specific bias tends to be very expensive. Hence, we sought to determine the reliable cause of systematic dye bias after treating murine macrophage RAW 264.7 cells with 2-keto-3-deoxyoctonate (KDO), interferon-beta (IFN-beta), and 8-bromoadenosine (8-BR). To find the cause of systematic dye bias from the point of view of fluorescence quenching, we examined the correlation between systematic dye bias and the proportion of each nucleotide in mRNA and oligonucleotide probe sequence. Cy3-dye bias was highly correlated with the proportion of adenines. Our results support the fact that systematic dye bias is affected by fluorescence quenching of each feature. In addition, we also found that the strength of fluorescence quenching is based on not only dye-dye interactions but also dye-nucleotide interactions as well.


Sujets)
Biais (épidémiologie) , Fluorescence , Expression des gènes , Interféron bêta , Macrophages , Séquençage par oligonucléotides en batterie , ARN messager , Transcriptome