International Journal of Laboratory Medicine ; (12): 77-79, 2015.
Article Dans Chinois | WPRIM | ID: wpr-459272

Résumé

Objective To develop an uncertainty study model of the enzymological reference method to systematically research the uncertainty influencing factors of 6 enzymological reference methods ALT,AST,LDH,AMY,GGT and CK for determining the key factors influencing the reference method and better guiding the establishment and operation of the enzymological reference methods.Methods The uncertainty of the six enzymological reference methods was evaluated by the theoretical evaluation com-bined with the experiment design according to series of standards including JJF1059-1999 Evaluation and Expression of Uncertainty in Measurement,JJF1135-2005 Evaluation of Uncertainty in Chemical Analytical Measurement,CANA-GL06 Guidance on Evalua-ting the Uncertainty in Chemical Analysis and CNAS-CL33 Guidance on the Application of Testing and Calibration Laboratories Competence Accreditation Criteria in the Field of Clinical Enzymology Reference Measurement.Results The established enzymo-logical uncertainty study model was C=ΔAΔt · 1ε · 1L ·V 1 +V 2 +V SV ·fT ·f pH ·fλ·fkit ·fresult .Conclusion The uncertainty e-S valuation model is set up and successfully applied in the uncertainty evaluation of the six enzymological reference methods.

2.
International Journal of Laboratory Medicine ; (12): 2521-2522, 2014.
Article Dans Chinois | WPRIM | ID: wpr-454358

Résumé

Objective As a collaborator of Beijing Institute of Medical Device Testing for value assignment of state standard ma-terial candidate Cystatin-C ,we have used the internationally accepted reference material to assign value for state standard material candidate Cystatin-C ,and help Beijing Institute of Medical Device Testing get Cystatin-C national standard material certificate . Methods According to the target value and operational procedure of international reference material ERM-DA471 ,We have tested 6 dilutions of standard material candidate Cystatin-C on calibrated Hitachi 7180 immunoassay system .Results The results demon-strate good repeatability and commutability ,and have been accepted in calculating the final value for the candidate standard materi-al ,our data has assisted Beijing Institute of Medical Device Testing in passing the criteria and obtaining Cystatin-C national standard material certificate .Conclusion Compared to the data from all participating collaborators ,our results hit right on the target value , and no significant matrix effects have been observed .

SÉLECTION CITATIONS
Détails de la recherche