Archives of Plastic Surgery ; : 338-343, 2021.
Article Dans Anglais | WPRIM | ID: wpr-889412

Résumé

Purpura fulminans is a serious condition that can result in severe morbidity in the pediatric population. Although autologous skin grafts remain the gold standard for the coverage of partial- to full-thickness wounds, they have several limitations in pediatric patients, including the lack of planar donor sites, the risk of hemodynamic instability, and the limited graft thickness. In Singapore, an in-house skin culture laboratory has been available since 2005 for the use of cultured epithelial autografts (CEAs), especially in burn wounds. However, due to the fragility of CEAs, negative-pressure wound therapy (NPWT) dressings have been rarely used with CEAs. With several modifications, we report a successful case of NPWT applied over a CEA in an infant who sustained 30% total body surface area full-thickness wounds over the anterior abdomen, flank, and upper thigh secondary to purpura fulminans. We also describe the advantages of using NPWT dressing over a CEA, particularly in pediatric patients.

2.
Archives of Plastic Surgery ; : 338-343, 2021.
Article Dans Anglais | WPRIM | ID: wpr-897116

Résumé

Purpura fulminans is a serious condition that can result in severe morbidity in the pediatric population. Although autologous skin grafts remain the gold standard for the coverage of partial- to full-thickness wounds, they have several limitations in pediatric patients, including the lack of planar donor sites, the risk of hemodynamic instability, and the limited graft thickness. In Singapore, an in-house skin culture laboratory has been available since 2005 for the use of cultured epithelial autografts (CEAs), especially in burn wounds. However, due to the fragility of CEAs, negative-pressure wound therapy (NPWT) dressings have been rarely used with CEAs. With several modifications, we report a successful case of NPWT applied over a CEA in an infant who sustained 30% total body surface area full-thickness wounds over the anterior abdomen, flank, and upper thigh secondary to purpura fulminans. We also describe the advantages of using NPWT dressing over a CEA, particularly in pediatric patients.

3.
Archives of Plastic Surgery ; : 449-452, 2017.
Article Dans Anglais | WPRIM | ID: wpr-142217

Résumé

The nipple-sharing technique for nipple reconstruction offers excellent tissue matching. The method used for nipple graft harvesting determines the quality of the graft and hence, the success of nipple sharing. Here, we described a guillotine technique wherein the nipple is first transfixed with 2 straight needles to stabilise it. Two No. 11 blades are then inserted in the center and simultaneously swept outwards to amputate the distal portion of the nipple. This technique provides good control, resulting in a very evenly cut base. The recipient bed is deepithelialized thinly, and the nipple graft is inset with interrupted 8-0 nylon sutures under magnification. Being a composite graft, it is protected with splint dressings for 6 weeks, and the dressing is regularly changed by the surgeon. The height of the nipple grafts ranges from 4 to 8 mm. This technique was performed in 9 patients with an average follow-up of 2.9 years (range, 1–4.5 years). Apposition between the nipple graft and its bed is crucial for the success of this technique. When correctly applied, we observed rapid revascularization of the graft.


Sujets)
Humains , Autogreffes , Bandages , Tumeurs du sein , Études de suivi , Lambeaux tissulaires libres , Méthodes , Aiguilles , Mamelons , Nylons , Attelles , Matériaux de suture , Transplants
4.
Archives of Plastic Surgery ; : 449-452, 2017.
Article Dans Anglais | WPRIM | ID: wpr-142216

Résumé

The nipple-sharing technique for nipple reconstruction offers excellent tissue matching. The method used for nipple graft harvesting determines the quality of the graft and hence, the success of nipple sharing. Here, we described a guillotine technique wherein the nipple is first transfixed with 2 straight needles to stabilise it. Two No. 11 blades are then inserted in the center and simultaneously swept outwards to amputate the distal portion of the nipple. This technique provides good control, resulting in a very evenly cut base. The recipient bed is deepithelialized thinly, and the nipple graft is inset with interrupted 8-0 nylon sutures under magnification. Being a composite graft, it is protected with splint dressings for 6 weeks, and the dressing is regularly changed by the surgeon. The height of the nipple grafts ranges from 4 to 8 mm. This technique was performed in 9 patients with an average follow-up of 2.9 years (range, 1–4.5 years). Apposition between the nipple graft and its bed is crucial for the success of this technique. When correctly applied, we observed rapid revascularization of the graft.


Sujets)
Humains , Autogreffes , Bandages , Tumeurs du sein , Études de suivi , Lambeaux tissulaires libres , Méthodes , Aiguilles , Mamelons , Nylons , Attelles , Matériaux de suture , Transplants
5.
Archives of Plastic Surgery ; : 240-241, 2015.
Article Dans Anglais | WPRIM | ID: wpr-109101

Résumé

No abstract available.