Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 4 de 4
Filtre
Ajouter des filtres








Gamme d'année
1.
Korean Journal of Radiology ; : 776-783, 2012.
Article Dans Anglais | WPRIM | ID: wpr-39916

Résumé

OBJECTIVE: To compare between the American College of Radiology (ACR) accreditation phantom and digital mammography accreditation phantom in assessing the image quality in full-field digital mammography (FFDM). MATERIALS AND METHODS: In each week throughout the 42-week study, we obtained phantom images using both the ACR accreditation phantom and the digital mammography accreditation phantom, and a total of 42 pairs of images were included in this study. We assessed the signal-to-noise ratio (SNR) in each phantom image. A radiologist drew a square-shaped region of interest on the phantom and then the mean value of the SNR and the standard deviation were automatically provided on a monitor. SNR was calculated by an equation, measured mean value of SNR-constant coefficient of FFDM/standard deviation. Two breast radiologists scored visible objects (fibers, specks, and masses) with soft-copy images and calculated the visible rate (number of visible objects/total number of objects). We compared SNR and the visible rate of objects between the two phantoms and calculated the k-coefficient for interobserver agreement. RESULTS: The SNR of the ACR accreditation phantom ranged from 42.0 to 52.9 (Mean, 47.3 +/- 2.79) and that of Digital Phantom ranged from 24.8 to 54.0 (Mean, 44.1 +/- 9.93) (p = 0.028). The visible rates of all three types of objects were much higher in the ACR accreditation phantom than those in the digital mammography accreditation phantom (p < 0.05). Interobserver agreement for visible rates of objects on phantom images was fair to moderate agreement (k-coefficients: 0.34-0.57). CONCLUSION: The ACR accreditation phantom is superior to the digital mammography accreditation phantom in terms of SNR and visibility of phantom objects. Thus, ACR accreditation phantom appears to be satisfactory for assessing the image quality in FFDM.


Sujets)
Femelle , Humains , Agrément , Région mammaire , Mammographie , Fantômes en imagerie , Amélioration d'image radiographique , Rapport signal-bruit , Sociétés médicales
2.
Journal of the Korean Society of Medical Ultrasound ; : 189-198, 2012.
Article Dans Coréen | WPRIM | ID: wpr-725509

Résumé

The use of autologous tissue transfer for breast augmentation is an alternative to using foreign implant materials. The benefits of this method are the removal of unwanted fat from other body parts, no risk of implant rupture, and the same feel as real breast tissue. However, sometimes there is a dilemma about whether or not to biopsy for calcifications or masses detected after the procedure is completed. The purpose of this study is to illustrate the procedures of breast augmentation with autologous tissues, the imaging features of various complications, and the role of imaging in the diagnosis and management of complications and hidden breast diseases.


Sujets)
Femelle , Biopsie , Région mammaire , Maladies du sein , Corps humain , Mammoplastie , Mammographie , Rupture
3.
Journal of Breast Cancer ; : 318-322, 2010.
Article Dans Anglais | WPRIM | ID: wpr-200693

Résumé

Primary breast lymphoma is a rare disease entity, particularly the T-cell type. There have been many case reports of primary breast lymphomas; however, these are mostly pathologic reports, with only a few reports in radiology literature. To the best of our knowledge, this is the first report on the radiologic features of primary T-cell type breast lymphoma, including mammography, ultrasonography, MR imaging, and 18 fluorodeoxyglucose positron emission tomography/computed tomography scan. The radiologic findings are rather unique for this T-cell lymphoma compared to B cell type.


Sujets)
Région mammaire , Tumeurs du sein , Électrons , Lymphomes , Lymphome T , Lymphome T périphérique , Imagerie par résonance magnétique , Mammographie , Maladies rares , Lymphocytes T , Tomodensitométrie , Échographie mammaire
4.
Korean Journal of Radiology ; : 175-178, 2008.
Article Dans Anglais | WPRIM | ID: wpr-82034

Résumé

Lansoprazole is an acid proton-pump inhibiting drug that is used for the treatment of duodenal or gastric ulcers, H. pylori infection, gastroesophageal reflux disease or Zollinger-Ellison syndrome. Although lansoprazole is well known for its gastrointestinal and dermatologic adverse effects, mild pulmonary symptoms are also known to develop from taking this drug. There have been no reports about lansoprazole-induced interstitial lung disease. We report here a case of lansoprazole-induced interstitial lung disease that developed in a 66-year-old man.


Sujets)
Sujet âgé , Humains , Mâle , (Pyridin-2-ylméthyl)sulfinyl-1H-benzimidazoles/effets indésirables , Antiulcéreux/effets indésirables , Biopsie/méthodes , Reflux gastro-oesophagien/traitement médicamenteux , Poumon/anatomopathologie , Pneumopathies interstitielles/induit chimiquement , Chirurgie thoracique vidéoassistée , Tomodensitométrie
SÉLECTION CITATIONS
Détails de la recherche