Psychiatry Investigation ; : 928-935, 2021.
Article Dans Anglais | WPRIM | ID: wpr-918743

Résumé

Objective@#Suicide is the 2nd leading cause of death in adolescence, and acute pediatric mental health emergency department (ED) visits have doubled in the past decade. The objective of this study was to evaluate physiologic parameters relationship to suicide severity. @*Methods@#This was a prospective, observational study from April 2018 thru November 2019 in a tertiary care pediatric emergency department (ED) and inpatient pediatric psychiatric unit enrolling acutely suicidal adolescent patients. Patients wore a wrist device that used photoplethysmography for 7 days during their acute hospitalization to measure heart rate variability (HRV). During that time, Columbia Suicide Severity Scores (CSSRS) were assessed at 3 time points. @*Results@#There was complete device data and follow-up for 51 patients. There was an increase in the high frequency (HF) component of HRV in patients that had a 25% or greater decrease in their CSSRS (mean difference 11.89 ms/ Hz ; p-value 0.005). Patients with a CSSRS≥15 on day of enrollment had a lower, although not statistically significant, HF component (mean difference -8.34 ms/ Hz; p-value 0.071). @*Conclusion@#We found an inverse correlation between parasympathetic activity measured through the HF component and suicidality in an acutely suicidal population of adolescents. Wearable technology may have the ability to improve outpatient monitoring for earlier detection and intervention.

SÉLECTION CITATIONS
Détails de la recherche