Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
Ajouter des filtres








Gamme d'année
1.
Chinese Journal of Surgery ; (12): 514-516, 2011.
Article Dans Chinois | WPRIM | ID: wpr-285694

Résumé

<p><b>OBJECTIVE</b>To measure the diameter and length of infrarenal inferior vena cava (IVC) in Shandong Peninsula adult through digital subtraction angiography (DSA) for better vena cava filter (VCF) choice and placement.</p><p><b>METHODS</b>From April 2008 to June 2010, 83 discontinuous patients (49 males and 34 females, mean age 56.4 years) with deep venous thrombosis (DVT) of lower extremity were placed VCF through DSA according to ACCP-8. During operation, diameter and length of infrarenal IVC were measured. At the same time, the renal vein location and the type of the IVC were identified to help the VCF choice.</p><p><b>RESULTS</b>All the VCFs were placed successfully, no complications occurred. The diameter of infrarenal IVC was 10 to 26 mm with a mean of (19 ± 5) mm. The average length from beginning of IVC to the lower renal vein was (10.6 ± 2.8) cm. The renal vein was located between the first and second lumbar vertebra, the IVC beginning was located between the fourth and fifth lumbar vertebra.</p><p><b>CONCLUSIONS</b>Diameter and length measurement of infrarenal IVC is helpful to the VCF selection and the domestic VCF research. Vena cava angiography is very important to the accurate placement of VCF.</p>


Sujets)
Femelle , Humains , Mâle , Adulte d'âge moyen , Asiatiques , Phlébographie , Filtres caves , Veine cave inférieure , Imagerie diagnostique
2.
Chinese Journal of Radiology ; (12)2001.
Article Dans Chinois | WPRIM | ID: wpr-679866

Résumé

Objective To investigate the early clinical outcome of peripheral cutting balloon(PCB) in the management of peripheral vessel stenosis.Methods Thirteen patients with peripheral limb vessel stenosis, in which 4 stenoses in hemodialysis access and 9 at lower limb arteries,underwent angioplasty by PCB.For multiple stenosis in the same vessel,the distal one should be expanded firstly.The balloon pressure was controlled in the range of 8 atm to 10 atm(1 atm=10.108 kPa).All the patient were given continuous anticoagulant therapy after the procedure.Results All the procedure were carried out successfully on the 13 patients,and no serious complications occured.The symptoms did not recur in all patients after the procedure.The 5 months' follow-up angiography proved that no restenosis occurred in one patient with previous stenosis at the hemodialysis access.Conclusion The angioplasty with PCB was a safe and reliable procedure in management of the peripheral limb vessel stenosis.The early outcome is satisfying.

SÉLECTION CITATIONS
Détails de la recherche