Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 20
Filtre
1.
Arq. bras. oftalmol ; 87(4): e2021, 2024. tab
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1520231

Résumé

ABSTRACT Purpose: To longitudinally compare isolated structural parameters obtained using RTVue optical coherence tomography in patients with glaucoma and suspected glaucoma with stable visual fields. Methods: All patients were required to have a reliable SITA Standard 24-2 Humphrey Visual Field test. Visual field stability was defined as having <5 points with p<5% and/or having no points with p<1% and/or p<0.05% in the glaucoma progression analysis comparison graph. Furthermore, the glaucoma assessment strategy was used in optical coherence tomography. Results: The study included 75 eyes from 75 patients, 43 of which had glaucoma and 32 had suspected glaucoma. The mean visual field intervals were 29.57 ± 9.65 months between the first and third tests. No visual field parameter variations (mean deviation, pattern standard deviation, and visual field index) and no retinal nerve fiber layer or optic disk parameter variations between the first and third tests were observed (p>0.05 for all), and no retinal nerve fiber layer parameter variations throughout the study were observed, except for optic disk parameters presenting with cup volume changes (p=0.004). However, ganglion complex cells presented a progressively decreased average ganglion cell complex parameter, with a variability of -0.98% ± 3.71% (p=0.04) between the first and third tests. By contrast, the global loss volume progressively increased throughout the study, with a variability of 14.71% ± 44.52% (p=0.04) between the first and third tests. The inferior ganglion cell complex parameter was significantly decreased between the first and third tests (p=0.02). Conclusion: The present findings suggest that patients with glaucoma or suspected glaucoma with stable visual fields may present structural ganglion complex cell progression as assessed using RTVue optical coherence tomography.


RESUMO Objetivo: Comparar longitudinalmente os parâmetros estruturais isolados obtidos através da tomografia de coerência óptica RTVue em pacientes glaucomatosos e suspeitos de glaucoma com campos visuais estáveis. Métodos: Todos os incluídos deveriam ter Campimetria Computadorizada Humphrey Sita Standard 24-2 confiáveis. A estabilidade campimétrica foi definida se apresentassem menos de cinco pontos com p<5% e/ou nenhum ponto com p<1% e/ou p<0,05% no gráfico de comparação do Glaucoma Progression Analysis. Para a tomografia de coerência óptica, foi utilizado a estratégia de avaliação para glaucoma. Resultados: Foram incluídos 75 olhos de 75 pacientes: 43 com glaucoma e 32 suspeitos. A média dos intervalos do campo visual entre o 1o e 3o exame, foi de 29,57 ± 9,65 meses. Não houve variação para os parâmetros do campo visual (desvio médio, desvio padrão e índice da função visual) entre o primeiro e o último exame (p>0,05 para todos). Não houve variação dos parâmetros da camada de fibras nervosas da retina ao longo do estudo, enquanto que para os parâmetros do disco óptico, apenas cup volume apresentou mudança (p=0,004). Em relação à camada de células ganglionares da retina, notou-se uma redução progressiva na espessura média da Ganglionar Complex Cells com uma variabilidade entre o primeiro e último exame de -0,98 ± 3,71% (p=0,04). Quanto ao Global loss volume, houve um aumento progressivo ao longo do estudo com uma variabilidade entre o primeiro e último exame de 14,71 ± 44,52% (p=0,04). O parâmetro inferior do Ganglionar Complex Cells também reduziu significativamente entre o 1o e 3o exames (p=0,02). Os demais parâmetros da tomografia de coerência óptica RTVue se mantiveram estáveis entre o 1o e 3o exames. Conclusão: Os presentes achados sugerem que pacientes glaucomatosos ou com suspeita de glaucoma e com campos visuais estáveis, podem apresentar progressão estrutural na camada de células ganglionares da retina avaliada por meio da tomografia de coerência óptica RTVue.

3.
Arq. bras. oftalmol ; 84(2): 113-120, Mar,-Apr. 2021. tab, graf
Article Dans Anglais | LILACS | ID: biblio-1153109

Résumé

ABSTRACT Purpose: To compare the use of visual field and/or optical coherence tomography (OCT) combined with color retinography by non-glaucoma specialists for differentiating glaucoma from physiological cupping. Methods: Eighty patients with glaucoma or physiological cupping (40 of each) were randomized according to the examination used (GI: color retinography, GII: color retinography + visual field, GIII: color retinography + optical coherence tomography, GIV: color retinography + visual field + optical coherence tomography). Twenty non-specialist ophthalmologists diagnosed glaucoma from PowerPoint slide images, without direct patient examination. Results: Inter-examiner agreement was good for GII (ĸ: 0.63; 95%CI, 0.53-0.72), moderate for GIII (ĸ: 0.58; 95%CI, 0.48-0.68) and GIV (ĸ: 0.41; 95%CI, 0.31-0.51), and low for GI (ĸ: 0.30; 95%CI, 0.20-0.39) (p<0.001). Diagnostic accuracy was higher in GIII (15.8 ± 1.82) than GI (12.95 ± 1.46, p<0.001) and higher in GII (16.25 ± 2.02) than GI and GIV (14.10 ± 2.24) (both p<0.001). For glaucoma patients only, diagnostic accuracy in GII and GIII was superior to that in GI and GIV (both p<0.001). Sensitivity and specificity were 59% and 70.5% in GI; 86.5% and 76% in GII, 86.5% and 71.5% in GIII; and 68.5% and 72.5% in GIV, respectively. Accuracy was highest in GII (81.3% [95%CI, 77.1-84.8]), followed by GIII (79% [95%CI, 74.7-82.7]), GIV (70,5% [95%CI, 65.9-74.8]), and GI (64.8% [95%CI, 60.0-69.3]). Conclusions: Non-glaucoma specialists could not differentiate glaucoma from increased physiological cupping when using color retinography assessment alone. Diagnostic accuracy and inter-rater agreement improved significantly with the addition of visual field or optical coherence tomography. However, the use of both modalities did not improve sensitivity/specificity.(AU)


RESUMO Objetivos: Verificar a influência do campo visual e/ou tomografia de coerência óptica, quando analisados em associação à retinografia colorida, na diferenciação entre indivíduos com glaucoma daqueles com aumento fisiológico de escavação. Métodos: Oitenta pacientes com glaucoma ou aumento fisiológico de escavação (40 cada) foram randomizados de acordo com o exame testado (GI: retinografia colorida, GII: retinografia colorida + campo visual, GIII: retinografia colorida + tomografia de coerência óptica, GIV: retinografia colorida + campo visual + tomografia de coerência óptica). Vinte oftalmologistas não especialistas em glaucoma diagnosticaram glaucoma através de slides do PowerPoint, sem o exame direto do paciente. Resultados: A concordância interexaminador foi boa para o GII (ĸ: 0,63; 95%CI, 0,53-0,72), moderada para GIII (ĸ: 0,58; 95%CI, 0,48-0,68) e GIV (ĸ: 0,41; 95%CI, 0,31-0,51), e baixa para o GI (ĸ: 0,30; 95%CI, 0,20-0,39) (p<0,001). Acurácia diagnostica foi maior no GIII (15,8 ± 1,82) em comparação ao GI (12,95 ± 1,46, p<0,001) e o GII (16,25 ± 2,02) maior em comparação ao GI e GIV (14,10 ± 2,24) (para ambos, p<0,001). Para os pacientes com glaucoma, a acurácia diagnostica nos grupos GII e GIII foi superior do que em GI e GIV (ambos p<0,001). Sensibilidade e especificidade foram 59% e 70,5% no GI; 86,5% e 76% no GII, 86,5% e 71,5% no GIII; 68,5% e 72,5% no GIV, respectivamente. A acurácia foi maior no GII (81,3% [95%CI, 77,1-84,8]), seguido pelo GIII (79% [95%CI, 74,7-82,7]), GIV (70,5% [95%CI, 65,9-74,8]), e GI (64,8% [95%CI, 60,0-69,3]). Conclusões: A avaliação isolada da retinografia colorida por oftalmologistas não especialistas em glaucoma não pode diferenciar pacientes com glaucoma daqueles com aumento fisiológico de escavação. Houve aumento da acurácia diagnóstica e da concordância interobservador com o acréscimo do campo visual ou da tomografia de coerência óptica. Entretanto, o uso de ambas as modalidades não melhorou a sensibilidade/especificadade.(AU)


Sujets)
Humains , Glaucome/imagerie diagnostique , Tomographie par cohérence optique , Spécialisation , Champs visuels , Tests du champ visuel
4.
Rev. bras. oftalmol ; 77(1): 25-29, jan.-fev. 2018. tab, graf
Article Dans Anglais | LILACS | ID: biblio-899108

Résumé

Abstract Objective: The main purpose of this article is to compare the predictability of biometric results and final refractive outcomes expected in patients undergoing cataract surgery through phacoemulsification with and without associated trabeculectomy. Methods: Cataract patients who have undergone phacoemulsification surgery alone (control group) or associated with trabeculectomy (study group) screened. All surgeries were performed following standard protocol. For enrollment, biometrics calculated by IOL Master (Carl Zeiss Meditec, Inc.) biometry, refraction and intraocular pressure (IOP) before and after surgery were required. Data was compared between groups in addition to the correlation between variation of IOP and final refraction. Results: Thirty eyes per group were enrolled. Only prior IOP (p <0.001), IOP post-surgery (p = 0.01) and the difference in IOP (p <0.001) were statistically significant. Axial length, IOL diopter used, expected spherical refraction by biometrics and astigmatism pre- and post-surgery were similar in both groups (p=0.1; 0.4; 0.4; 0.5 and 0.3, respectively). Spherical predictability by biometrics within 0.25 diopters was noted in both the control group (range 0.06 ± 0.45) and study group (range 0.25 ± 0.97, p = 0.3). There was no statistical significance between groups for the difference between final cylinder and corneal astigmatism (p = 0.9), and the difference between axis of refractive and corneal astigmatism (p = 0.7). Conclusion: The biometric predictability in phacoemulsification surgery and the expected final refraction are significant, andare not modified by trabeculectomy in the combined surgeries.


Resumo Objetivo: Comparar a previsibilidade dos resultados refracionais e da biometria em pacientes submetidos à cirurgia de catarata por facoemulsificação com e sem trabeculectomia (Trec) associada. Métodos: Pacientes com catarata submetidos à cirurgia de facoemulsificação isolada (grupo controle) ou associada a Trec (catarata + glaucoma, grupo estudo) foram consecutivamente selecionados. Todas as cirurgias foram feitas seguindo protocolo padrão. Para inclusão, era necessário apresentar biometria calculada pelo biômetro IOL Master (Carl Zeiss, Meditec, Inc), refração e pressão intraocular (Pio) pré e pós-operatórios. Os dados foram comparados entre os grupos, além da correlação entre a variação da Pio e a refração final. Resultados: Foram incluídos 30 olhos por grupo. Na comparação, apenas a Pio prévia (p<0,001), Pio pós cirurgia (p=0,01) e a diferença de Pio pré-pós cirurgia (3,8 ± 4,4mmHg vs. 15,5 ± 9,3mmHg, grupos controle e estudo, respectivamente, p<0,001) foram estatisticamente significativos. Diâmetro axial, dioptria da Lio utilizada, dioptria esperada pela biometria e astigmatismo prévio e pós- cirurgia foram estatisticamente semelhantes entre os grupos (p=0,1; 0,4; 0,4; 0,5 e 0.3, respectivamente). Notou-se previsibilidade esférica pela biometria dentro de 0,25 dioptrias, tanto no grupo controle (variação de 0,06 ± 0,45), quanto no grupo estudo (variação de 0,25 ± 0,97, p=0,3). Não houve significância estatística entre os grupos para a diferença entre o cilindro final e o astigmatismo corneano em dioptrias (p=0,9), e diferença entre o eixo do astigmatismo refracional e corneano (p=0,7). Conclusão: A previsibilidade biométrica e a refração na cirurgia de facoemulsificação aferida pelo biômetro IOL Master é significativa, e não sãoalteradas na cirurgia combinada com trabeculectomia.


Sujets)
Humains , Mâle , Femelle , Sujet âgé , Réfraction oculaire , Trabéculectomie/méthodes , Biométrie , Phacoémulsification/méthodes , Période postopératoire , Cataracte , Acuité visuelle , Glaucome , Résultat thérapeutique , Association thérapeutique , Pose d'implant intraoculaire , Pression intraoculaire
5.
Arq. bras. oftalmol ; 80(6): 386-389, Nov.-Dec. 2017. graf
Article Dans Anglais | LILACS | ID: biblio-888160

Résumé

ABSTRACT Purpose: To compare the linear measurements of the optic disk cup obtained using RTVue optical coherence tomography (OCT) with those obtained using digital retinography. Methods: This is a cross-sectional study performed with digital retinography and RTVue OCT images from patients with glaucoma or patients suspected of glaucoma. In color retinography, the greatest horizontal and vertical diameters of the optic disk starting from the inner edge of the Elschnig ring were obtained using a pachymeter with a grade of 0.01 mm. In OCT, the delineation of the optic nerve was obtained automatically from the horizontal and vertical cup results. Results: One hundred eyes from 100 subjects with a mean age of 60.1 ± 15.7 years were included. Of these, 79 were the right eye and 21 the left eye, with 61 men and 39 women. The mean horizontal cup obtained with OCT was 0.91 ± 0.10, while that obtained with retinography was 0.79 ± 0.11 (p<0.01). Conclusions: There was poor agreement between the evaluated methods in the measurements of optic disk cup excavations. Measurements obtained automatically with OCT RTVue were higher but were significantly correlated with measurements obtained manually with digital retinography. Poor agreement of the optic disk parameters between the two imaging devices was noted.


RESUMO Objetivo: Comparar as medidas lineares da escavação do disco óptico, obtidas com o OCT RTVue com as obtidas pela retinografia digital. Métodos: Trata-se de um estudo transversal. Utilizou-se imagens de retinografia digital e exames de OCT obtidos pelo aparelho RTVue de pacientes suspeitos ou com glaucoma. Na retinografia colorida, foram obtidos os maiores diâmetros horizontal e vertical do disco óptico, a partir da borda interna do Anel de Elschnig através de paquímetro com graduação de 0,01 mm. No OCT, a delineação do nervo óptico foi obtida automaticamente e a partir dos resultados foi registrado o diâmetro horizontal e vertical da escavação. Resultados: Foram incluídos 100 olhos de 100 indivíduos, com idade média de 60,1 ± 15,7 anos. Desses, 79 foram do olho direito e 21 do olho esquerdo, sendo 61 homens e 39 mulheres. Verificou-se que as médias das escavações horizontais obtidas com o OCT foram de 0,91 ± 0,10, enquanto que as obtidas pela retinografia foram 0,79 ± 0,11 (p<0,01). Conclusões: Nota-se fraca concordância entre os métodos avaliados para quantificar as medidas das escavações do disco óptico. As medidas obtidas automaticamente pelo OCT RTVue foram maiores, porém correlacionadas com as medidas obtidas manualmente pela retinografia digital. Além disso, notou-se fraca concordância nos parâmetros do disco óptico entre os dois dispositivos de imagens.


Sujets)
Humains , Mâle , Femelle , Adulte d'âge moyen , Glaucome/imagerie diagnostique , Rétine/imagerie diagnostique , Études transversales , Tomographie par cohérence optique , Techniques de diagnostic ophtalmologique
6.
Rev. bras. oftalmol ; 76(6): 285-288, nov.-dez. 2017. graf
Article Dans Anglais | LILACS | ID: biblio-899096

Résumé

Abstract Objective: To determine the influence of visual field results in the diagnosis of glaucoma. Methods: A questionnaire with ophthalmologists was conducted where slides of a digital photograph of the optic disc and computerized visual field exam were presented.(Physicians were instructed to answer whether glaucoma was observed in each of the slides). No other information was given to those examiners. Half of the patients had glaucoma with corresponding visual field, and the other half had physiological cupping and normal visual field. The slides were equally divided between retinography and corresponding visual field (same patient) and exams randomly exchanged, where an optic disc of glaucoma with a normal visual field was placed, and vice-versa. The order in which the slides were presented was also randomized. Results: Forty slides were evaluated by 29 ophthalmologists. No glaucoma specialist was included. The overall agreement among the examiners (Kappa) was 0.270 ± 0.281, and 0.261 ± 0.238 for the exams of the same eye and was 0.274 ± 0.217 from the slides with the exams changed (p=0.4). The diagnosis was made correctly in glaucoma patients with corresponding visual field exam in 66.89% of the cases, and in 66.20% of patients with physiological cupping. When the exams were exchanged, the results dropped to 34.13% and 35.86%, respectively (p<0.001 for both). Conclusion: Visual field results may influence the diagnosis of glaucoma by non-glaucoma specialists.


Resumo Objetivo: Avaliar a influência da campimetria computadorizada no diagnóstico do glaucoma. Métodos: Foi realizado questionário com oftalmologistas apresentando slides com uma fotografia digital de disco óptico e campo visual computadorizado. Os médicos deveriam assinalar se o exames apresentados eram de glaucoma ou não. Nenhuma outra informação foi passada para os examinadores. Metade dos pacientes apresentavam glaucoma com dano correspondente de campo visual, e a outra metade aumento fisiológico da escavação e campo visual normal. Os slides foram igualmente divididos em: retinografia e campo visual correspondentes (mesmo paciente) e exames invertidos de forma aleatória, colocando um disco óptico de glaucoma com um campo visual normal e vice-versa. A ordem de apresentação dos slides foi randomizada previamente. Resultados: Foram incluídos 40 slides, avaliados por 29 oftalmologistas. Nenhum especialista em glaucoma foi incluído. A concordância entre os examinadores (Kappa) foi de 0,270 ± 0,281, sendo de 0,261 ± 0,238 para os exames correspondentes e 0,274 ± 0,217 para os slides com os exames trocados (p=0,4). O diagnóstico foi realizado corretamente nos pacientes com glaucoma com o campo visual correspondente em 66,89% dos casos, e em 66,20% nos pacientes com aumento da escavação (normais). Quando houve a troca da correspondência dos exames, os valores caíram para 34,13% e 35,86%, respectivamente (p<0,001 para ambos). Conclusão: O conhecimento prévio dos resultados do campo visual pode influenciar o diagnóstico do glaucoma.


Sujets)
Humains , Papille optique/imagerie diagnostique , Photographie (méthode) , Glaucome/diagnostic , Tests du champ visuel , Rétine/imagerie diagnostique , Champs visuels , Biais de l'observateur , Enquêtes et questionnaires , Reproductibilité des résultats , Ophtalmologistes , Neurofibres/anatomopathologie
7.
Rev. bras. oftalmol ; 70(3): 142-146, maio-jun. 2011. tab
Article Dans Portugais | LILACS | ID: lil-596336

Résumé

OBJETIVO: Avaliar a camada de fibras nervosas da retina (CFNR) em pacientes com anemia falciforme sem glaucomaatravés da tomografia de coerência óptica (OCT). MÉTODOS: O estudo selecionou pacientes com anemia falciforme (homozigotos SS), provenientes do ambulatório de hematologia da Universidade Federal de Goiás, e voluntários normais controlados por raça e idade. Para serem incluídos, os integrantes de ambos os grupos deveriam apresentar acuidade visual e" 20/30 sem correção, pressão intraocular (Pio) d" 21mmHg, campo visual SITA Standard 24-2 e disco óptico sem alterações sugestivas de glaucoma. Os pacientes eram encaminhados para exame da CFNR por meio do OCT, estratégia Fast RNFL, e os dados comparados entre os grupos. RESULTADOS: Foram selecionados 24 pacientes (24 olhos) por grupo. A média da idade foi de 25,2 ± 14,9 anos no grupo da anemia falciforme e 20,5 ± 12,5 anos nos pacientes normais (p=0,09). Não houve diferença estatisticamente significativa ao se comparar a espessura média da CFNR entre o grupo de estudo e o grupo controle para todos os quadrantes pesquisados. CONCLUSÃO: O presente estudo não evidenciou lesão da CFNR aferida através da Tomografia de Coerência Óptica em pacientes com anemia falciforme sem alterações oftalmológicas presentes ao exame clínico.


PURPOSE: To evaluate the retinal nerve fiber layer (RNFL) in sickle cell disease with optical coherence tomography (OCT). METHODS:The present study selected patients with sickle cell disease (SS) from the Federal University of Goias, and normalvolunteers, controlled by age and sex. Inclusion criteria for both groups were: visual acuity e" 20/30 without correction, intraocular pressure d" 21mmHg and a reliable and normal 24-2 Sita Standard visual field and optic disc. Thereafter, all subjects were submitted to OCT, Fast RNFL strategy, and the results compared between groups. RESULTS: Twenty-four patients (24 eyes) were included per group. The mean age was 25.2 ± 14.9 years in the sickle cell group and 20.5 ± 12.5 years in the normal subjects (p=0.09). There was no statistically difference in the mean RNFL thickness between both groups in all areas evaluated. CONCLUSION: There was no statistically difference in the mean RNFL thickness measured by OCT between normal individuals and patients with sickle cell disease with normal ophthalmic.

8.
Arq. bras. oftalmol ; 72(5): 661-664, set.-out. 2009. ilus, tab
Article Dans Portugais | LILACS | ID: lil-534187

Résumé

OBJETIVO: Comparar o efeito analgésico entre dipirona sódica e etoricoxib 90 mg após exérese de pterígio primário com transplante autólogo de conjuntiva. MÉTODOS: Trata-se de um ensaio clínico prospectivo, randomizado, duplo-mascarado. Três grupos de 26 pacientes (1 olho por paciente) foram operados e receberam as medicações em estudo durante os cinco dias seguintes à cirurgia. Foi utilizada uma escala de dor, numerada de zero a dez, para avaliação pelo paciente no 1É, 3É e 5É dias pós-operatórios. A dor foi classificada em ausente (zero), leve (1 a 3), moderada (4 a 7) e intensa (8 a 10). A análise estatística foi realizada com o software SPSS, versão 11.5. RESULTADOS: Foi observada diferença estatisticamente significativa entre etoricoxib e dipirona no 1É e 3É dia pós-operatório (PO) (p=0,001 e p=0,01; respectivamente). O etoricoxib foi superior ao placebo apenas no 1É PO (p=0,04). Não houve diferença de resultados entre dipirona e placebo. CONCLUSÕES: A analgesia do etoricoxib foi superior à do placebo no PO1 e à da dipirona no PO1 e PO3, na exérese de pterígio primário com transplante autólogo de conjuntiva. Não houve diferença significativa da analgesia pós-operatória entre dipirona e placebo no mesmo procedimento.


Purpose: To compare the analgesic effect between dipyrone, 90 mg etoricoxib, and placebo after excision of primary pterygium with conjunctival autograft. METHODS: Prospective, randomized, double-masked clinical trial. Three groups of 26 patients (one eye per patient) were submitted to surgery and received the study drugs for five days after surgery. A scale of pain was used, graduated from zero to ten, for patient evaluation in the first, third and fifth postoperative days. The pain was classified as absent (zero), mild (1 to 3), moderate (4 to 7) and severe (8 to 10). Statistical analysis was performed with the SPSS, version 11.5. RESULTS: A statistically significant difference was found between etoricoxib and dipyrone in the first and third postoperative days (p=0.001 and p=0.01; respectively). Etoricoxib was superior to placebo only in the first postoperative day (p=0.04). There was no significance in the comparison between dipyrone and placebo. CONCLUSIONS: Analgesia of etoricoxib was superior to placebo in the first postoperative day and to dipyrone in the third and fifth days after excision of primary pterygium with conjunctival autograft. There was no significant difference between dipyrone and placebo in all time points.


Sujets)
Adulte , Femelle , Humains , Mâle , Analgésiques , Conjonctive/transplantation , Métamizole sodique , Pyridines , Douleur postopératoire/traitement médicamenteux , Ptérygion/chirurgie , Sulfones , Méthode en double aveugle , Études prospectives , Mesure de la douleur/méthodes , Douleur postopératoire/physiopathologie , Facteurs temps
9.
Arq. bras. oftalmol ; 72(3): 365-369, May-June 2009. graf
Article Dans Portugais | LILACS | ID: lil-521473

Résumé

OBJETIVO: Avaliar os efeitos do uso do colírio de ibopamina a 2 por cento nos resultados da campimetria visual computadorizada em indivíduos normais. MÉTODOS: Voluntários oriundos do CEROF-UFG, sem alterações ao exame oftalmológico que pudessem afetar o campo visual foram selecionados. Os indivíduos foram submetidos a exame de perimetria computadorizada SITA-standard 24-2 antes e após dilatação com o colírio de ibopamina a 2 por cento ou ciclopentolato, com intervalo mínimo de 3 dias entre si e em ordem aleatória. Índices globais e número de pontos alterados foram comparados entre os grupos. RESULTADOS: Foram avaliados 30 olhos de 30 indivíduos normais. Não houve diferença estatisticamente significativa entre o "mean deviation" (MD) nos pacientes não dilatados e nos mesmos após a instilação da ibopamina (MD: -1,05 ± 0,26 dB vs. -1,47 ± 0,20 dB, P=0,08), o que ocorreu após cicloplegia (MD: -3,19 ± 0,29 dB), P<0,001 para ambos. Na avaliação entre cicloplegia e pré-dilatação, nota-se significância para o "pattern standard deviation" (P=0,04), o que não ocorreu na avaliação com ibopamina. O número de pontos alterados no "pattern deviation" não apresentou diferença significativa entre todos os pares. Quanto ao número de pontos do "total deviation", houve diferença estatisticamente significativa antes da dilatação e após o uso do cicloplégico (n: 8,86 ± 1,51 vs. 25,72 ± 2,96 pontos, P<0,001) e entre olhos após a instilação do cicloplégico e da ibopamina (ibopamina: 9,75 ± 1,85 pontos, P<001). CONCLUSÃO: O colírio de ibopamina 2 por cento aparentemente não afeta os resultados da perimetria computadorizada em indivíduos normais.


PURPOSE: To evaluate the influence of 2 percent ibopamine eye drops on the results of computerized visual field exams. METHODS: Normal volunteers from CEROF-UFG were selected, with no variance in the ophthalmologic examination that could affect the visual field test. The volunteers underwent computerized visual field test before and after dilation with 2 percent ibopamine eye drop or cyclopentolate, with a minimum interval of three days between them and in a random order. Global indices and number of altered points were compared between the groups. RESULTS: Thirty eyes of 30 normal individuals were selected. There was no statistically significant difference on Mean Deviation (MD) before and after dilation with ibopamine (MD: -1.05 ± 0.26 dB vs. -1.47 ± 0.20 dB, P=0.08). However, after cycloplegia (MD: -3.19 ± 0.29 dB), there was a significant difference on MD (P<0.001 for both ibopamine and pre-dilation). No significant difference was detected in the Pattern Standard Deviation when comparing ibopamine with pre-dilation and cycloplegia values, but it was statistically significant comparing pre-dilation to cycloplegia (P=0.04). The number of altered points in the Pattern Deviation graphic were not significant comparing all pairs. There was a statistically significant difference in the number of altered points in the total deviation graphic before dilation and after cycloplegia (n: 8.86 ± 1.51 vs. 25.72 ± 2.96 points, P<0.001), and comparing cycloplegia with ibopamine (ibopamine: 9.75 ± 1.85 points, P<0.001). CONCLUSION: Ibopamine 2 percent eye drops seem to not modify the results of visual field tests in normal individuals.


Sujets)
Adulte , Femelle , Humains , Mâle , Désoxyadrénaline/analogues et dérivés , Mydriatiques/administration et posologie , Tests du champ visuel , Champs visuels/effets des médicaments et des substances chimiques , Cyclopentolate/administration et posologie , Interprétation statistique de données , Désoxyadrénaline/administration et posologie , Traitement d'image par ordinateur , Solutions ophtalmiques/administration et posologie , Facteurs temps
10.
Rev. bras. anestesiol ; 58(6): 569-581, nov.-dez. 2008. ilus, tab
Article Dans Anglais, Portugais | LILACS | ID: lil-497045

Résumé

JUSTIFICATIVA E OBJETIVOS: Comparar a qualidade e a segurança da anestesia retrobulbar (ARB) para tratamento de catarata por facoemulsificação utilizando agulhas de dois diferentes tamanhos: 25 x 0,70 mm ou 20 x 0,55 mm. MÉTODOS: Seleção prospectiva de candidatos a bloqueio oftálmico para tratamento de catarata por facoemulsificação. Após sedação e monitorização padronizada, foi realizada anestesia retrobulbar (ARB) em punção única ínfero-lateral com 4 mL de ropivacaína 1 por cento, contendo hialuronidase. No Grupo I (GI) a agulha utilizada foi de 25 x 0,70 mm e no Grupo II (GII), de 20 x 0,55 mm. Em um paciente de cada grupo foram realizadas tomografias computadorizadas no momento da realização do bloqueio oftálmico e após cinco minutos da administração da solução anestésica com contraste radiológico. A mobilidade ocular foi avaliada após três, cinco e dez minutos. Por meio de um questionário padronizado, foram comparadas a incidência de complicações entre os grupos, a satisfação dos pacientes e cirurgiões. RESULTADOS: Foram avaliados 54 pacientes adultos (27 por grupo). Nenhum paciente relatou dor ou percepção luminosa intra-operatória. O procedimento anestésico foi considerado muito bom (MB) ou excelente (E) em 96,30 por cento dos casos nos dois grupos. A mesma avaliação foi feita por 100 por cento dos pacientes. Não houve diferença na necessidade de repetição do bloqueio entre os grupos (p = 1,0). O GI apresentou menor mobilidade ocular aos 3 minutos (p = 0,03). Observou-se o posicionamento da agulha em posição retrobulbar intraconal em ambos os grupos. A dispersão anestésica foi similar entre os grupos aos 5 minutos. CONCLUSÃO: A ARB realizada com a agulha de 20 × 0,55 mm, em punção única ínfero-lateral, utilizando baixas doses de anestésicos, se apresenta como uma opção eficaz e segura para tratamento de catarata por facoemulsificação.


BACKGROUND AND OBJECTIVES: The objective of this study was to compare the quality and safety of retrobulbar block for the treatment of cataracts by phacoemulsification using needles of different sizes: 27 × 0.70 mm and 20 × 0.55 mm. METHODS: Candidates for ophthalmic block for the treatment of cataracts by phacoemulsification were selected prospectively. After sedation and standardized monitoring, a retrobulbar block with 4 mL of 1 percent ropivacaine containing hyaluronidase was performed with a single inferolateral puncture. In Group I (GI), the 25 × 0.70 mm needle was used, while in Group II (GII) a 20 × 0.55 mm needle was used. All patients had a CT scan at the time of the blockade and five minutes after the administration of the anesthetic solution with radiologic contrast. Ocular mobility was assessed after three, five, and ten minutes. The incidence of complications in both groups and the satisfaction of patients and surgeons were compared by applying a standardized questionnaire. RESULTS: Fifty-four adult patients were evaluated (27 per group). Patients did not complain of intraoperative pain or perception of light. The anesthetic procedure was considered very good (VG) or excellent (E) in 96.3 percent of the cases in both groups. All patients were subjected to the same assessment. The need of block repetition between both groups did not differ (p = 1.0). Patients in GI showed decreased ocular mobility at 3 minutes (p = 0.03). The intraconal retrobulbar placement of the needle was observed on both groups. Anesthetic dispersion at 5 minutes was similar in the two groups. CONCLUSIONS: Retrobulbar block with a single inferolateral puncture with a 20 × 0.55 mm needle, using low doses of anesthetics, is an effective and safe option for the treatment of cataracts by phacoemulsification.


JUSTIFICATIVA Y OBJETIVOS: Comparar la calidad y la seguridad de la anestesia retrobulbar (ARB) para tratamiento de catarata por facoemulsificación, utilizando agujas de dos diferentes tamaños: 25 x 0,70 mm o de 20 x 0,55 mm. MÉTODOS: Selección prospectiva de candidatos a bloqueo oftálmico para tratamiento de catarata por facoemulsificación. Después de la sedación y monitoreo estandarizado, se realizó anestesia retrobulbar (ARB) en punción única ínfero-lateral con 4 mL de ropivacaina 1 por ciento, con hialuronidasa. En el Grupo I (GI), la aguja utilizada fue de 25 x 0,70 mm y en el Grupo II (GII), de 20 x 0,55 mm. En un paciente de cada grupo fueron realizadas tomografías computadorizadas al momento de la realización del bloqueo oftálmico y después de cinco minutos de la administración de la solución anestésica con contraste radiológico. La movilidad ocular se evaluó después de tres, cinco y diez minutos. A través de un cuestionario estandarizado, se compararon la incidencia de complicaciones entre los grupos, y la satisfacción de los pacientes y de los cirujanos. RESULTADOS: Fueron evaluados 54 pacientes adultos (27 por grupo). Ningún paciente relató dolor o percepción luminosa intraoperatoria. El procedimiento anestésico fue considerado muy bueno (MB) o excelente (E) en un 96,30 por ciento de los casos en los dos grupos. La misma evaluación se hizo en un 100 por ciento de los pacientes. No hubo diferencia en la necesidad de repetición del bloqueo entre los grupos (p = 1,0). El GI presentó menor movilidad ocular a los 3 minutos (p = 0,03). Se observó el posicionamiento de la aguja en posición retrobulbar intraconal en los dos grupos. La dispersión anestésica fue similar entre los grupos a los 5 minutos. CONCLUSIÓN: La ARB realizada con la aguja de 20 x 0,55mm, en punción única ínfero-lateral, utilizando bajas dosis de anestésicos, se presenta como una opción eficaz y segura para el tratamiento de catarata por facoemulsificación.


Sujets)
Humains , Aiguilles/normes , Anesthésie de conduction/méthodes , Phacoémulsification/instrumentation , Extraction de cataracte
11.
Arq. bras. oftalmol ; 71(4): 499-503, jul.-ago. 2008. graf
Article Dans Portugais | LILACS | ID: lil-491878

Résumé

OBJETIVO: Comparar o teste da ibopamina 2 por cento com o teste de sobrecarga hídrica como testes provocativos para glaucoma. MÉTODOS: Pacientes com glaucoma primário de ângulo aberto, e indivíduos normais foram selecionados do CEROF-Universidade Federal de Goiás - UFG, e submetidos, de forma randomizada, e com intervalo mínimo de 1 semana, aos testes provocativos da ibopamina 2 por cento, e sobrecarga hídrica. A pressão intra-ocular (Pio) antes e após os testes, confrontação entre os métodos (gráfico de Bland-Altman) além da melhor relação sensibilidade/especificidade (realizados por meio de curvas ROC) foram obtidos. RESULTADOS: Foram incluídos 47 olhos de 25 pacientes (27 olhos de 15 pacientes com glaucoma e 20 olhos de 10 pacientes normais), com idade média de 54,2 ± 12,7 anos. O MD médio dos pacientes com glaucoma foi de -2,8 ± 2,11 dB. Nos pacientes com glaucoma, não houve diferença estatisticamente significativa na Pio basal (p=0,8), ao passo que se notou diferença na Pio após os testes provocativos (p=0,03), e na variação da Pio após os testes (4,4 ± 1,3 mmHg para ibopamina e 3,2 ± 2,2 mmHg para ingestão hídrica, p=0,01). Nos pacientes normais, não houve diferença estatisticamente significativa entre os grupos para todos os parâmetros avaliados. O gráfico de Bland-Altman mostrou grande dispersão dos resultados. Finalmente, obteve-se áreas abaixo das curvas ROC de 0,987 para o teste da ibopamina e 0,807 para a ingestão hídrica. CONCLUSÃO: O teste provocativo da ibopamina apresentou melhor relação sensibilidade/especificidade que o teste de ingestão hídrica nesse subgrupo selecionado de pacientes com glaucoma com dano perimétrico inicial.


PURPOSE: To compare the 2 percent ibopamine provocative test with the water drinking test as a provocative test for glaucoma. METHODS: Primary open-angle glaucoma patients and normal individuals were selected from CEROF-Universidade Federal de Goiânia UFG, and underwent the 2 percent ibopamine provocative test and the water drinking test in a randomized fashion, at least 1 week apart. Intraocular pressure (IOP) before and after both tests, Bland-Altman graph, sensitivity and specificity (as mesured by ROC curves) were obtained for both methods. RESULTS: Forty-seven eyes from 25 patients were included (27 eyes from 15 glaucoma patients and 20 eyes from 10 normal individuals), with a mean age of 54.2 ± 12.7 years. The mean MD of glaucoma patients was -2.8 ± 2.11 dB. There was no statistically difference in the baseline IOP (p=0.8) comparing glaucoma patients, but positive after the provocative tests (p=0.03), and in the IOP variation (4.4 ± 1.3 mmHg for ibopamine and 3.2 ± 2.2 mmHg for water drinking test, p=0.01). There was no difference in all studied parameters for normal individuals. The Bland-Altman graph showed high dispersion comparing both methods. The areas under the ROC curve were 0.987 for the ibopamine provocative test, and 0.807 for the water-drinking test. CONCLUSION: In this selected subgroup of glaucoma patients with early visual field defect, the ibopamine provocative test has shown better sensitivity/specificity than the water drinking test.


Sujets)
Humains , Adulte d'âge moyen , Consommation de boisson , Désoxyadrénaline/analogues et dérivés , Glaucome à angle ouvert/diagnostic , Mydriatiques , Eau , Techniques de diagnostic ophtalmologique , Désoxyadrénaline , Méthodes épidémiologiques , Pression intraoculaire/effets des médicaments et des substances chimiques
12.
Arq. bras. oftalmol ; 70(3): 509-512, maio-jun. 2007. tab
Article Dans Portugais | LILACS | ID: lil-459841

Résumé

OBJETIVO: Avaliar a concordância e correlação entre a perimetria de freqüência dupla e a perimetria azul-amarelo no glaucoma. MÉTODOS: Pacientes com glaucoma foram selecionados do Setor de Glaucoma do Centro de Referência em Oftalmologia (CEROF) da Universidade Federal de Goiás, e submetidos aos exames de perimetria de freqüência dupla e perimetria azul-amarelo em ambos os olhos (quando elegíveis) no mesmo dia de maneira aleatória. Foi obtido a correlação (Pearson) entre os índices globais (mean deviation - MD e pattern standard deviation - PSD) e a concordância entre os exames (índice Kappa) para a gravidade do dano glaucomatoso. RESULTADOS: Quarenta e três olhos de 26 pacientes foram incluídos no estudo. Comparando-se o MD (-4,5±4,5 dB para o perimetria de freqüência dupla e -8,0±6,8 dB para o perimetria azul-amarelo, p<0,001) e o PSD (6,4±2,8 dB para o perimetria de freqüência dupla e 5,8±2,4 dB para o perimetria azul-amarelo, p=0,1), verificamos que apenas o MD mostrou diferença estatisticamente significativa entre os grupos. Os índices globais MD e PSD foram altamente correlacionados comparando-se o perimetria de freqüência dupla e o perimetria azul-amarelo (r=0,644, p<0,001 e r=0,586, p<0,001, respectivamente). A concordância entre as classificações da gravidade da perda glaucomatosa mostrou-se significativa (Kappa=0,319, p<0,001). CONCLUSÃO: Existe alta correlação entre os índices globais e alta concordância em termos de classificação da gravidade do dano glaucomatoso entre a perimetria azul-amarelo e a perimetria de freqüência dupla, refletindo ausência de seletividade no dano glaucomatoso, ou que os instrumentos disponíveis não sejam capazes de isolar as células ganglionares de forma completa.


PURPOSE: To test the agreement and correlation between the frequency doubling technology and the short wavelength perimetry in glaucoma. METHODS: Glaucoma patients were selected from the Glaucoma Sector of CEROF - Universidade Federal de Goiás, and then underwent frequency doubling technology and short wavelength perimetry examinations in both eyes (if eligible) on the same day in a random sequence. Pearson's correlation between the global indices (mean deviation - MD e pattern standard deviation - PSD) and the agreement between the examinations (Kappa) were obtained. RESULTS: Forty-three eyes from 26 patients were included in the study. Comparing the MD (-4.5±4.5 dB for the frequency doubling technology and -8.0±6.8 dB for the short wavelength perimetry, p<0.001) and PSD (6.4±2.8 dB for the FDT and 5.8±2.4 dB for SWAP, p=0.1), only MD was statistically different between the groups. The global indices MD e PSD were highly correlated between the frequency doubling technology and short wavelength perimetry (r=0.644, p<0.001 and r=0.586, p<0.001, respectively). There was a high agreement between the examinations (Kappa=0.319, p<0.001). CONCLUSION: In the present study, a high correlation between the global indices (MD and PSD) by the frequency doubling technology and short wavelength perimetry was found, as well as a high agreement between the examinations. These observations indicate either that both cell populations are similarly affected by glaucomatous damage or that both methods measure activity in the same cell populations.


Sujets)
Femelle , Humains , Mâle , Adulte d'âge moyen , Glaucome/diagnostic , Tests du champ visuel , Reproductibilité des résultats , Indice de gravité de la maladie
13.
Arq. bras. oftalmol ; 69(5): 695-699, set.-out. 2006. graf, tab
Article Dans Anglais, Portugais | LILACS | ID: lil-439317

Résumé

PURPOSE: To compare intraocular pressure (IOP) rise in normal individuals and primary open-angle glaucoma patients and the safety and efficacy of ibopamine eye drops in different concentrations as a provocative test for glaucoma. METHODS: Glaucoma patients underwent (same eye) the ibopamine provocative test with two concentrations, 1 percent and 2 percent, in a random sequence at least 3 weeks apart, but not more than 3 months. The normal individuals were randomly submitted to one of the concentrations of ibopamine (1 percent and 2 percent). The test was considered positive if there was an IOP rise greater than 3 or 4 mmHg at 30 or 45 minutes to test which subset of the test has the best sensitivity (Se)/specificity (Sp). RESULTS: There was no statistically significant difference in any of the IOP measurements, comparing 1 percent with 2 percent ibopamine. The IOP was significantly higher at 30 and 45 minutes with both concentrations (p<0.001). The best sensitivity/specificity ratio was achieved with the cutoff point set as greater than 3 mmHg at 45 minutes with 2 percent ibopamine (area under the ROC curve: 0.864, Se: 84.6 percent; Sp:73.3 percent). All patients described a slight burning after ibopamine's instillation. CONCLUSION: 2 percent ibopamine is recommended as a provocative test for glaucoma. Because both concentrations have similar ability to rise IOP, 1 percent ibopamine may be used to treat ocular hypotony.


OBJETIVO: Comparar a tolerabilidade e a eficácia do teste provocativo da ibopamina com diferentes concentrações em pacientes com glaucoma primário de ângulo aberto. MÉTODOS: Pacientes com glaucoma (mesmo olho) foram aleatoriamente submetidos ao teste provocativo da ibopamina com as duas concentrações comercialmente disponíveis: 1 por cento e 2 por cento com pelo menos 3 semanas de intervalo, mas não superior a 3 meses. Os indivíduos normais foram randomizados a uma das concentrações utilizadas. O teste era considerado positivo se houvesse elevação da pressão intra-ocular (Pio) superior a 3 ou 4 mmHg 30 ou 45 minutos após o início do teste para se estabelecer a melhor relação sensibilidade (Se)/especificidade (Es) do teste. RESULTADOS: Treze pacientes com glaucoma, 15 indivíduos normais com a ibopamina a 2 por cento e 13 com a ibopamina a 1 por cento foram incluídos. Não houve diferença estatisticamente significativa em qualquer uma das médias da Pio entre a ibopamina a 1 por cento ou a 2 por cento. A Pio foi significativamente maior aos 30 e 45 minutos com ambas as concentrações (p<0,001). A melhor relação Se/Es foi obtida com o aumento da Pio >3 mmHg, 45 minutos após o teste com a ibopamina a 2 por cento (área abaixo da curva ROC: 0,864, Se: 84,6 por cento; Es: 73,3 por cento). Todos os pacientes referiram leve ardência à instilação da ibopamina. CONCLUSÃO: Sugere-se a utilização da ibopamina a 2 por cento como teste provocativo para o glaucoma. Como ambas as concentrações apresentaram capacidade similar em elevar a Pio, a Ibopamina a 1 por cento (menor concentração da droga) pode ser utilizada por períodos prolongados, como na hipotonia ocular.


Sujets)
Humains , Mâle , Femelle , Adulte d'âge moyen , Désoxyadrénaline/analogues et dérivés , Agonistes de la dopamine , Glaucome à angle ouvert/diagnostic , Pression intraoculaire/effets des médicaments et des substances chimiques , Mydriatiques , Agonistes de la dopamine/administration et posologie , Glaucome à angle ouvert/traitement médicamenteux , Mydriatiques/administration et posologie , Solutions ophtalmiques , Études prospectives , Sensibilité et spécificité , Facteurs temps , Tests de vision
14.
Arq. bras. oftalmol ; 69(4): 477-480, jul.-ago. 2006. graf, tab
Article Dans Anglais, Portugais | LILACS | ID: lil-435728

Résumé

PURPOSE: To correlate the ibopamine provocative test with the diurnal tension curve (highest intraocular pressure-IOP and range) in glaucoma. METHODS: This is a prospective case series including glaucoma patients from the Federal University of Goiás, Glaucoma Service. Two 2 percent ibopamine eyedrops were instilled into one or both eyes of each patient, 5 minutes apart. Intraocular pressure was checked before and 30 and 45 minutes after the second ibopamine instillation. Thereafter, the diurnal tension curve of each patient was assessed with five independent measurements (at every 2:30 hours), from 8:00 o'clock AM to 6:00 o'clock PM. Pearson's correlation coefficient was used to test the linear relation between the intraocular pressure after the ibopamine instillation with the highest intraocular pressure value and the intraocular pressure range in the diurnal curve. RESULTS: Thirty-one eyes from 22 patients were included. There was a significant correlation between the intraocular pressure 30 and 45 minutes after ibopamine instillation and the highest intraocular pressure assessed in the diurnal curve (r=0.356, p=0.04 and r=0.429, p=0.01, respectively). However, no correlation between IOP after the use of ibopamine and the diurnal intraocular pressure range at 30 (r=0.046, p=0.8) and 45 minutes (r=0.109, p=0.5) was observed. CONCLUSION: The ibopamine provocative test shows a significant correlation with the highest intraocular pressure in the diurnal tension curve in glaucoma patients. However, no correlation was observed with the intraocular pressure range.


OBJETIVO: Correlacionar o teste provocativo da ibopamina com a curva diurna de pressão intra-ocular (Pio máxima e flutuação da mesma) em pacientes com glaucoma. MÉTODOS: Estudo prospectivo incluindo pacientes com glaucoma provenientes do CEROF-UFG. Duas gotas de ibopamina a 2 por cento foram instiladas em um ou ambos os olhos dos pacientes com intervalo de 5 minutos entre elas. A pressão intra-ocular foi checada antes, 30 e 45 minutos após a segunda gota de ibopamina. Após, a curva diurna de pressão intra-ocular foi realizada com 5 medidas independentes (a cada 2:30 horas) entre 8:00 e 18:00 horas. A correlação de Pearson foi utilizada para se testar a relação linear entre a pressão intra-ocular após o uso da ibopamina, a pressão intra-ocular máxima e a flutuação diurna da pressão intra-ocular. RESULTADOS: Trinta e um olhos de 22 pacientes foram incluídos. Notou-se correlação estatisticamente significativa entre a Pio 30 e 45 minutos após a instilação da ibopamina e a máxima pressão intra-ocular obtida na curva diurna (r=0,356, p=0,04 e r=0,429, p=0,01, respectivamente). Entretanto, não foi observada correlação positiva com a flutuação diurna da pressão intra-ocular aos 30 (r=0,046, p=0,8) e 45 minutos (r=0,109, p=0,5). CONCLUSÃO: O teste provocativo da ibopamina apresentou alta correlação com a pressão intra-ocular máxima na curva diurna em pacientes com glaucoma. Entretanto, não foi notado relação linear direta com a flutuação diurna da pressão intra-ocular.


Sujets)
Humains , Mâle , Femelle , Adulte d'âge moyen , Désoxyadrénaline/analogues et dérivés , Glaucome à angle ouvert/diagnostic , Pression intraoculaire/effets des médicaments et des substances chimiques , Mydriatiques , Tonométrie oculaire/méthodes , Études prospectives , Facteurs temps
15.
Arq. bras. oftalmol ; 69(2): 193-196, mar.-abr. 2006. tab, graf
Article Dans Portugais | LILACS | ID: lil-426715

Résumé

OBJETIVO: Avaliar o desempenho do teste provocativo da ibopamina em pacientes com glaucoma usuários de drogas hipotensoras. MÉTODOS: Pacientes glaucomatosos foram recrutados do Centro de Referência em Oftalmologia (CEROF) da Universidade Federal de Goiás, e suas drogas hipotensoras em uso registradas. Indivíduos normais foram amigos e parentes dos pacientes. A seguir, foram instiladas duas gotas de ibopamina 2 por cento com intervalo de 5 minutos. A pressão intra-ocular (Pio) foi medida previamente, e após 30, 60 e 180 minutos. No nosso estudo, o teste da ibopamina foi considerado positivo quando a pressão intra-ocular excedeu 4 mmHg em pelo menos uma das medidas. RESULTADOS: Cinquenta e oito olhos de 58 indivíduos (38 glaucomatosos e 20 normais) foram incluídos no estudo. O aumento da pressão intra-ocular foi maior nos pacientes com glaucoma aos 30, 60 e 180 minutos (p<0,001 em todas as ocasiões). O aumento da pressão intra-ocular foi estatisticamente maior aos 30 minutos nos indivíduos que não utilizavam análogos das prostaglandinas (p=0,01). A sensibilidade do teste foi de 68 por cento (87 por cento se excluirmos pacientes em uso de análogos das prostaglandinas), e a especificidade de 95 por cento. CONCLUSÃO: O teste provocativo da ibopamina 2 por cento pode ser ferramenta auxiliar no diagnóstico do glaucoma. Apesar da pequena amostra estudada, sugere-se que olhos em uso de análogos das prostaglandinas têm reduzido a sensibilidade do mesmo.


Sujets)
Humains , Désoxyadrénaline/analogues et dérivés , Agonistes de la dopamine , Glaucome/diagnostic , Pression intraoculaire/effets des médicaments et des substances chimiques , Prostaglandines synthétiques/usage thérapeutique , Tonométrie oculaire , Désoxyadrénaline/administration et posologie , Désoxyadrénaline , Glaucome/traitement médicamenteux , Sensibilité et spécificité , Facteurs temps
16.
Arq. bras. oftalmol ; 69(1): 51-55, jan.-fev. 2006. tab
Article Dans Portugais | LILACS | ID: lil-420818

Résumé

OBJETIVO: Comparar a influência do tipo de tratamento em diferentes regiões do campo visual glaucomatoso após reducão da pressão intra-ocular (Pio). MÉTODOS: Pacientes com glaucoma que obtiveram reducão da Pio de pelo menos 20 por cento em um período de 2 meses foram retrospectivamente selecionados e divididos em 2 grupos: 1) após trabeculectomia; 2) após tratamento clínico. índices do campo visual e os limiares de sensibilidade (totais, e divididos de acordo com a gravidade no gráfico do "Pattern Deviation") foram anotados imediatamente antes e após a reducão da Pio, comparados entre os grupos, e dentro dos mesmos. RESULTADOS: Trinta e um olhos de 22 pacientes foram incluídos no estudo (15 no grupo 1, e 16 no grupo 2). Ambos os grupos demonstraram alta habilidade na melhora de regiões do campo visual após a reducão da Pio. Apenas a porcentagem da reducão da Pio (52,3n18,9 por cento e 37,8n15,2 por cento para os grupos 1 e 2, respectivamente, p=0,02) e a porcentagem de melhora nos pontos lesados a 0,5 por cento (186,0n213,3 por cento e 30,1n35,2 por cento para os grupos 1 e 2, respectivamente, p=0,02) foram diferentes entre os grupos, porém sem significância após correcão do erro alfa. CONCLUSAO: A reducão da Pio acima de 20 por cento pode estar associada à melhora em regiões do campo visual glaucomatoso, independente da modalidade de tratamento.


Sujets)
Humains , Glaucome à angle ouvert/physiopathologie , Pression intraoculaire/physiologie , Hypertension oculaire/physiopathologie , Champs visuels/physiologie , Glaucome à angle ouvert/traitement médicamenteux , Glaucome à angle ouvert/chirurgie , Hypertension oculaire/traitement médicamenteux , Hypertension oculaire/chirurgie , Études rétrospectives , Tonométrie oculaire , Trabéculectomie
17.
Arq. bras. oftalmol ; 67(2): 249-254, mar.-abr. 2004. tab, graf
Article Dans Portugais | LILACS | ID: lil-362252

Résumé

OBJETIVOS: Avaliar a capacidade da polarimetria de varredura a laser de discriminar entre olhos normais e glaucomatosos. MÉTODOS: Cento e doze pacientes com glaucoma primário de ângulo aberto e 88 indivíduos normais foram incluídos no estudo. Todos os indivíduos foram submetidos a exame oftalmológico completo, perimetria computadorizada (Humphrey 24-2, full threshold), avaliando-se Mean Deviation (MD) e Correct Pattern Standard Deviation (CPSD) e exame com GDx. Curvas ROC foram criadas e novos pontos de corte para cada parâmetro individual do GDx estabelecidos para estabelecer uma melhor relação sensibilidade/especificidade (Se/Es) no diagnóstico do glaucoma. A seguir, uma função discriminante com 2 parâmetros do GDx (ellipse modulation e the number) e idade por meio da análise logística multivariada foi criada com o mesmo propósito. RESULTADOS: Os parâmetros individuais do GDx com melhor relação Se/Es foram: the number (Se: 79,5 por cento, Es: 81,8 por cento, área abaixo da curva ROC: 0,870), maximum modullation (Se: 83,0 por cento, Es: 76,1 por cento, área abaixo da curva ROC: 0,842) e ellipse modulation (Se: 65,2 por cento, Es: 88,6 por cento, área abaixo da curva ROC: 0,831). A função discriminante criada obteve resultados superiores a qualquer parâmetro do GDx isolado (Se: 85,7 por cento, Es: 90,9 por cento, a área abaixo da curva ROC: 0,920). CONCLUSAO: A combinação de dois ou mais fatores em uma função logística multivariada aumenta a capacidade da polarimetria de varredura a laser de discriminar entre olhos normais e glaucomatosos.


Sujets)
Humains , Mâle , Femelle , Adulte d'âge moyen , Glaucome , Lasers , Tests du champ visuel , Analyse multifactorielle , Études prospectives , Sensibilité et spécificité
18.
Arq. bras. oftalmol ; 67(1): 73-78, jan.-fev. 2004. tab, graf
Article Dans Portugais | LILACS | ID: lil-359351

Résumé

OBJETIVOS: Avaliar a correlação entre os parâmetros do Topógrafo de Disco Optico (TOPSS) e índices da perimetria computadorizada. MÉTODOS: Cento e doze pacientes com glaucoma primário de ângulo aberto e 88 indivíduos normais foram incluídos no estudo. Todos os indivíduos foram submetidos ao exame oftalmológico completo, perimetria computadorizada (Humphrey 24-2, Full Threshold), avaliando-se Mean Deviation (MD) e Correct Pattern Standard Deviation (CPSD) e exame com TOPSS (average disc diameter, total disc area, cup area, cup shape, cup volume, average cup depth, average disc depth, neuroretinal rim (NRR) volume, NRR area, cup/disc area ratio, horizontal cup/disc ratio e vertical cup/disc ratio). A comparação entre os grupos foi realizada utilizando-se o Teste U de Mann-Whitney ou o Teste T de Student Independente. A correlação entre cada parâmetro do TOPSS e os índices do campo visual foi verificada utilizando-se a correlação de Spearman. RESULTADOS: Os parâmetros do TOPSS que apresentaram as correlações mais significativas com os índices de campo visual foram: Cup Area (MD: r = -0,538, p<0,001; CPSD: r =0,512, p<0,001), Vertical C/D Ratio (MD: r = -0,506, p<0,001; CPSD: r = 0,483, p<0,001) e Cup/Disc Area Ratio (MD: r = -0,458, p<0,001; CPSD: r = 0,453, p<0,001). Entretanto, houve importante variabilidade desses parâmetros em diferentes níveis de dano glaucomatoso, representados pelo MD e CPSD. CONCLUSAO: As variáveis do TOPSS apresentam, no geral, correlação satisfatória com os índices do campo visual. Apesar de alguns desses parâmetros apresentarem correlação altamente significativa, existe grande variabilidade dos parâmetros estruturais para um mesmo nível de dano funcional, limitando a utilização isolada de parâmetros estruturais derivados do TOPSS no diagnóstico do glaucoma.


Sujets)
Humains , Mâle , Femelle , Adulte d'âge moyen , Techniques de diagnostic ophtalmologique , Papille optique/anatomopathologie , Glaucome à angle ouvert , Tests du champ visuel , Études prospectives , Champs visuels
19.
Rev. bras. oftalmol ; 62(10): 740-746, out. 2003. ilus, tab
Article Dans Portugais | LILACS | ID: lil-360999

Résumé

Objetivo: Verificar a influência do diâmetro pupilar na Perimetria de Frequência Dupla (FDT) em indivíduos normais. Local: Centro de Referência em Oftalmologia (CEROF) da Universidade Federal de Goiás. Métodos: Vinte pacientes normais foram submetidos à FDT, estratégia de screening C-20-5, inicialmente com a pupila sem alterações, e em seguida em miose ou midríase, aleatóriamente. Os exames foram realizados com intervalo máximo de 15 dias. O número de pontos alterados, índices de confiabilidade e tempo de exame foi comparado entre os exames. Resultados: Os voluntários apresentaram menor tempo de exame em midríase (p=0,006) comparado com a pupila sem alterações. Não houve diferença estatísticamente significante com relação ao exame de pupila em miose (p=0,7). Não observamos alterações estatisticamente significantes no número total de pontos alterados entre o exame com a pupila sem alterações (0,8 +- 1,76 pontos) e miose (2,0 +- 4,3 pontos) (p=0,3). entretanto, observamos melhora considerável nos pacientes após midríase (0,1 +- 0,30 pontos alterados) (p=0,04). Conclusão: Apesar de não apresentar diferença estatisticamente significante no número total de pontos alterados, os olhos em miose demonstraram maior número de áreas acometidas, podendo refletir em diferenças clínicas. Entretanto, os pacientes em midríase apresentaram menor número de pontos alterados com um menor tempo de exame.


Sujets)
Humains , Adolescent , Adulte , Adulte d'âge moyen , Glaucome , Myosis , Mydriase , Pupille , Tests du champ visuel , Pression intraoculaire , Acuité visuelle
20.
Arq. bras. oftalmol ; 66(3): 299-304, maio-jun. 2003. ilus, tab
Article Dans Portugais | LILACS | ID: lil-345638

Résumé

OBJETIVO: Avaliar as flutuações que ocorrem a curto e a longo prazos e a curva de aprendizado que ocorre em indivíduos normais submetidos à perimetria de freqüência dupla. MÉTODOS: Vinte indivíduos normais foram submetidos à perimetria de freqüência dupla, durante quatro sessões, com intervalos semanais. Na última sessão, realizaram-se três exames seguidos. As médias de sensibilidade e as flutuações a curto e longo prazos foram calculadas. Foi também avaliada a curva de aprendizado, pela comparação dos valores de MD ("mean deviation") nas quatro sessões. RESULTADO: Na avaliação a curto prazo, a média total de sensibilidade foi 31,91 ± 1,20 dB e as médias de MD e PSD ("pattern standard deviation") foram 0,84 ± 1,85 e 3,73 ± 1,55 dB, respectivamente. A média total das flutuações a curto prazo foi 1,72 ± 0,38 dB. Na avaliação a longo prazo, a média total de sensibilidade foi 31,75 ± 1,11 dB e as médias de MD e PSD foram 0,68 ± 1,90 dB e 3,67 ± 0,10 dB, respectivamente. A média total das flutuações a longo prazo foi 2,16 ± 0,26 dB. Os MDs médios da primeira, segunda, terceira e quarta sessões foram 0,11 ± 2,14 dB, 0,47 ± 1,64 dB, 1,16 ± 1,62 dB e 0,98 ±1,92 dB, respectivamente. Observou-se aumento significativo do MD na terceira e quarta sessões em relação à primeira sessão (p< 0,05). CONCLUSÃO: As sensibilidades detectadas pela perimetria de freqüência dupla apresentam flutuação a curto e longo prazo. Observou-se também claro efeito do aprendizado que deve ser considerado quando se realiza esse tipo de exame pela primeira vez.


Sujets)
Adulte , Apprentissage , Tests du champ visuel , Champs visuels , Manométrie , Microscopie , Réfraction oculaire/physiologie , Tests de vision , Acuité visuelle
SÉLECTION CITATIONS
Détails de la recherche