Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 1 de 1
Filtre
Ajouter des filtres








Gamme d'année
1.
Acta bioquím. clín. latinoam ; 41(1): 51-56, ene.-mar. 2007. tab
Article Dans Espagnol | LILACS | ID: lil-632993

Résumé

El objetivo del trabajo fue evaluar la efectividad de un programa de auditoría clínica para vigilar y reducir la magnitud de errores preanalíticos en el Laboratorio de Guardia de un hospital público de la provincia de Buenos Aires. En un período de 2004 y otro de 2005 se relevaron los diferentes tipos de errores en 11.949 recipientes de muestras de sangre y orina. Se calcularon los indicadores: porcentaje de errores preanalíticos totales en las muestras (% EP), de muestras coaguladas, de recipientes inadecuados, de volumen inadecuado, de muestras hemolizadas, de muestras batidas y de identificación inadecuada. Se capacitó al personal de enfermería. Se asignaron los costos correspondientes a las etapas de obtención y remisión de muestras de la fase preanalítica. El % EP no presentó modificaciones significativas en 2004, mientras que en 2005 sus variaciones acompañaron las de algunos de los restantes indicadores. Los costos correspondientes a errores preanalíticos constituyeron en promedio el 10% de los costos totales de obtención y remisión de muestras en los períodos estudiados. Se concluye que las actividades de capacitación deben realizarse en forma periódica y someterse a seguimiento continuo a fin de obtener disminuciones significativas y perdurables en la magnitud de los errores preanalíticos.


The aim of this study was to evaluate the effectiveness of a clinical audit program to monitor and reduce the magnitude of pre-analytical errors in the Emergency Laboratory of a Buenos Aires Province public hospital. During a 2004 period and another 2005 one, different types of errors were surveyed in 11.949 blood- and urine-sample flasks. The following indicators were calculated: sample pre-analytical error percentage (% PE), as well as percentages corresponding to coagulated samples, inadequate flask use, inadequate flask volume, samples that underwent haemolysis, shaken samples and poor sample identification. Nursing personnel were trained. Costs incurred were allocated to the extraction and delivery stages within the pre-analytical phase. PE % did not show any meaningful changes in 2004, while in 2005 its variations followed those of some of the other indicators. Costs attributed to pre-analytical error represented 10% of total cost of sample extraction and delivery in the periods that were studied. It can be concluded that training courses must be periodically offered and their results monitored on a permanent basis if any significant and long-lasting reduction in the magnitude of pre-analytical errors is to be achieved.


Sujets)
Contrôle de qualité , Audit clinique , Équipement de Laboratoire , Valeurs critiques de laboratoire
SÉLECTION CITATIONS
Détails de la recherche