Japanese Journal of Cardiovascular Surgery ; : 180-183, 1998.
Article Dans Japonais | WPRIM | ID: wpr-366397

Résumé

A patient with mutiple aneurysms of the thoracic aorta in Behçet's disease was treated with transluminally placed endovascular stent grafts. Stent graft devices composed of several units of self-expandable Z stents covered with ultra-thin woven Dacron were inserted through 18 Fr sheaths via the femoral arteries. The stent grafts were deployed successfully and blood flow into the aneurysms was reduced immediately and no blood endoleak was found on aortography. However minor endoleak due to migrations of the stent grafts was recognized in two distal descending aortic aneurysms twenty days after the operation. Extra stent grafts were inserted to interrupt the endoleak and finally all aneurysms were thrombosed without any endoleak. Former surgical replacement of the aorta due to aneurysms associated with vasculo-Behçet's disease often causes anastomotic leakage and pseudoaneurysms. The endoluminal stent graft treatment is a minimally invasive operation in comparison with former surgical operations, and is useful for aortic aeurysms especially for inflammatory aneurysms in Behçet's disease because it requires no anastomotis. However, improvement of the stent graft devices, including components of the delivery system such as the dilator, sheath and pushing rod, and the development of better devices, is required to reduce delivery failure and to make stent graft treatment more reliable.