Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
Ajouter des filtres








Gamme d'année
1.
Arq. bras. med. vet. zootec. (Online) ; 71(3): 857-862, May-June 2019. tab, graf
Article Dans Portugais | VETINDEX, LILACS | ID: biblio-1011315

Résumé

Atualmente o uso de sensores portáteis para mensuração de corpos cetônicos está padronizado e difundido na rotina clínica, contudo estudos em ovinos são escassos. Assim, a presente pesquisa objetivou avaliar a acurácia dos sensores portáteis de uso humano e de uso veterinário para a determinação de beta-hidroxibutirato (BHB) em ovelhas no final da gestação e no pós-parto recente. Foram utilizadas 37 amostras de sangue provenientes de nove ovelhas mestiças Corriedale. A determinação bioquímica de BHB no soro, considerada como o padrão-ouro, foi realizada utilizando-se metodologia enzimática colorimétrica. A média obtida na bioquímica sérica foi de 0,497mmol/L; no sensor de uso humano, a média foi igual a 0,537mmol/L, enquanto no sensor de uso veterinário foi de 0,751mmol/L. Foi verificada alta correlação entre o dosímetro de uso humano e o padrão-ouro (r=0,93, P<0,001). A média do aparelho de uso veterinário diferiu das demais (51%; P<0,05), superestimando os resultados em ovelhas. As medições obtidas no aparelho veterinário também apresentaram menor precisão e veracidade. Concluiu-se que o sensor portátil de uso humano é mais acurado e mais preciso no diagnóstico precoce de toxemia da gestação em ovelhas.


Currently the use of portable sensors for measuring ketone bodies is standardized and diffused in the clinical routine, however, studies in sheep are scarce. Therefore, the present study aimed to evaluate the accuracy of the human portable sensor and the veterinary portable sensor for the determination of beta-hydroxybutyrate (BHB) in sheep at the end of gestation and postpartum. We used 37 samples of blood from nine crossbred Corriedale sheep. Biochemical determination of serum BHB, considered gold standard, was performed using colorimetric enzymatic methodology. The mean serum biochemistry was 0.497mmol/L, in the human sensor the mean was 0.537mmol/L, while in the veterinary sensor it was 0.751mmol/L. A high correlation was verified between the dosimeter for human use and the gold standard (r= 0.93, P< 0.001). The mean of the veterinary apparatus differed from the others, being 51% (P< 0,05), higher than the standard, that is, it was less accurate and had lower veracity, overestimating the results in sheep. It was concluded that the portable sensor for human use is more accurate and accurate in the early diagnosis of toxemia of pregnancy in sheep.


Sujets)
Animaux , Femelle , Grossesse , Pré-éclampsie/médecine vétérinaire , Ovis/sang , Acide 3-hydroxy-butyrique/sang , Cétose/diagnostic , Cétose/sang , Cétose/médecine vétérinaire
2.
Rev. bras. reprod. anim ; 13(4): 247-53, 1989. tab
Article Dans Portugais | LILACS | ID: lil-114078

Résumé

Foram obtidos dados de perímetro escrotal e peso corporal de 666 carneiros apresentados em exposiçöes feiras realizadas nos anos de 1985, 1986 e 1987, das raças Suffolk, Hampshire Down, Ile de France e Texel, com diferentes idades. Os resultados mostraram diferença no perímetro escrotal quanto à idade apenas na raça Hampshire Down. Para todas as raças observou-se correlaçäo significativa entre peso corporal e perímetro escrotal. Os baixos coeficientes de determinaçäo no entanto, näo recomendam o peso corporal como único estimador do perímetro escrotal


Sujets)
Animaux , Mâle , Biométrie , Testicule , Ovis
SÉLECTION CITATIONS
Détails de la recherche