Resumen Introducción: Aun con adecuado protocolo de desconexión de la ventilación mecánica (DVM), el procedimiento falla en 15 a 30 % de los casos. Objetivo: Evaluar la asociación entre factores de riesgo independientes y fracaso posextubación en pacientes con DVM en una unidad de cuidados intensivos. Método: Estudio de cohorte, longitudinal, prospectivo, analítico, que incluyó pacientes sometidos a ventilación mecánica por más de 24 horas y que fueron extubados. Se obtuvieron reportes preextubación de hemoglobina, albúmina, fósforo, índice cintura-cadera y puntuación SOFA. Se definió como fracaso de extubación al reinicio de la ventilación mecánica en 48 horas o menos. Resultados: Se extubaron 123 pacientes, 74 hombres (60 %); la edad promedio fue de 50 ± 18 años. Ocurrió fracaso de extubación en 37 (30 %). Como factores de riesgo independentes se asoció hipoalbuminemia en 29 (23.8 %, RR = 1.43, IC 95 % = 1.11-1.85) e hipofosfatemia en 18 (14.6 %, RR = 2.98, IC 95 % = 1.66-5.35); se observaron dos o más factores de riesgo independientes en 22.7 % (RR = 1.51, IC 95 % = 1.14-2.00). Conclusiones: Identificar los factores de riesgo independentes antes de la DVM puede ayudar a reducir el fracaso de la extubación y la morbimortalidad asociada.


Abstract Introduction: Even with an adequate mechanical ventilation weaning (MVW) protocol, the procedure fails in 15 to 30 % of cases. Objective: To assess the association between independent risk factors (IRFs) and post-extubation failure in patients undergoing MVW in an intensive care unit. Method: Longitudinal, prospective, analytical cohort study in patients on mechanical ventilation for more than 24 hours and who were extubated. Pre-extubation reports of hemoglobin, albumin, phosphorus, waist-hip ratio and SOFA score were obtained. Extubation failure was defined as resumption of mechanical ventilation within 48 hours or less. Results: 123 patients were extubated, out of whom 74 were males (60 %); average age was 50 ± 18 years. Extubation failure occurred in 37 (30 %). Hypoalbuminemia was associated as an independent risk factor in 29 (23.8 %, RR = 1.43, 95 % CI = 1.11-1.85) and hypophosphatemia was in 18 (14.6 %, RR = 2.98, 95 % CI = 1.66-5.35); two or more IRFs were observed in 22.7 % (RR = 1.51, 95 % CI = 1.14-2.00). Conclusions: Identifying independent risk factors prior to MVW can help reduce the risk of extubation failure and associated morbidity and mortality.


Sujets)
Humains , Mâle , Femelle , Adulte d'âge moyen , Sevrage de la ventilation mécanique , Extubation/effets indésirables , Phosphore/sang , Facteurs temps , Sérumalbumine/analyse , Études transversales , Études prospectives , Facteurs de risque , Études de cohortes , Reprise du traitement , Enquêtes sur les soins de santé/statistiques et données numériques , Rapport taille-hanches , Extubation/statistiques et données numériques , Unités de soins intensifs
SÉLECTION CITATIONS
Détails de la recherche