Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtre
Ajouter des filtres








Gamme d'année
1.
Indian J Ophthalmol ; 2023 Sep; 71(9): 3270-3271
Article | IMSEAR | ID: sea-225254

Résumé

Background: Zonular weakness is a known complication that a surgeon can encounter during cataract surgery. Purpose: The purpose of this video is to make surgeons aware about the different tools and techniques available to handle zonulopathy. Synopsis: This video describes the various causes of zonular weakness and different tools available to manage zonular weakness intraoperatively. The surgical technique of using the tools is also demonstrated in the video. Highlights: Causes of zonular weakness and surgical techniques to handle it intraoperatively.

2.
Indian J Ophthalmol ; 2022 Apr; 70(4): 1203-1207
Article | IMSEAR | ID: sea-224234

Résumé

Purpose: To compare the efficacy of Kane formula with Sanders Retzlaff Kraff/Theoretical (SRK/T) and Barrett Universal II in predicting intraocular lens (IOL) power in Indian eyes. Methods: This retrospective study conducted in a tertiary care eye hospital. Data from patients having uneventful cataract surgery with Tecnis ZCB00 IOL implantation were obtained from Lenstar and electronic medical records. Eyes were divided into subgroups based on axial length (AL) as short (<22.0 mm), medium (22� mm), and long (>24 mm). The predicted refractive outcome for each patient was calculated after optimizing the lens constant. Prediction error was calculated by subtracting the predicted spherical equivalent from achieved spherical equivalent 1 week post?surgery. The mean absolute error (MAE) and median absolute error (MedAE) and percentage of eyes within 0.25, 0.5, 1, and 2 D were calculated for each formula. Friedman test, Cochrane Q test were used for statistical analysis. Results: Out of the 350 eyes included in the study, we found that without lens constant optimization, Barrett formula performed better than SRK/T and Kane (P < 0.0001). Over the entire range of axial lengths, Kane formula performed slightly inferior compared to Barrett and SRK?T, both of which performed equally well (P = 0.006). On subgroup analysis, Kane formula performed inferiorly for medium eyes as compared to the other two. No significant differences were noted between the formulae for short and long eyes. Conclusion: Kane formula did not outperform Barrett Universal II and SRK/T in Indian eyes

3.
Indian J Ophthalmol ; 2015 Nov; 63(11): 869
Article Dans Anglais | IMSEAR | ID: sea-179020
SÉLECTION CITATIONS
Détails de la recherche