Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
Ajouter des filtres








Gamme d'année
1.
Journal of Zhejiang University. Science. B ; (12): 193-204, 2019.
Article Dans Anglais | WPRIM | ID: wpr-1010451

Résumé

In this work, a novel conjugate of ractopamine and bovine serum albumin (RAC-BSA) has been developed via the Mannich reaction, with a mole coupling ratio for RAC-BSA of 9:1. The proposed conjugation method provides a simple and one-step method with the use of fewer reagents compared with other conjugation methods for competitive immunoassays. RAC-BSA conjugation was used to fabricate a competitive lateral flow strip test for RAC detection in animal feed. For sample preparation, RAC was spiked in swine feed purchased from the local markets in Thailand, and methanol and running buffer at a volume ratio of 10:90 was used as extraction buffer. The procedures for sample preparation were completed within 25 min. Under optimal conditions, the limit of detection (LOD), assessed by the naked eye within 5 min, was found to be 1 ng/g. A semi-quantitative analysis was also conducted using a smart phone and computer software, with a linearity of 0.075-0.750 ng/g, calculated LOD of 0.10 ng/g, calculated limit of quantitation of 0.33 ng/g, and good correlation of 0.992. The recoveries were found in the range of 96.4%-103.7% with a relative standard deviation of 2.5%-3.6% for intra- and inter-assays. Comparison of the results obtained by the strip test with those obtained by enzyme-linked immunosorbent assay had a good agreement in terms of accuracy. Furthermore, this strip test exhibited highly specific RAC detection without cross reactivity with related compounds. Therefore, the RAC-BSA conjugation via the Mannich reaction can be accepted as a one-step and easy conjugation method and applied to the competitive lateral flow strip test.


Sujets)
Animaux , Aliment pour animaux/analyse , Réactions croisées , Test ELISA/méthodes , Limite de détection , Phénéthylamines/composition chimique , Bandelettes réactives , Sérumalbumine bovine/composition chimique , Suidae
2.
Journal of Zhejiang University. Science. B ; (12): 193-204, 2019.
Article Dans Anglais | WPRIM | ID: wpr-847066

Résumé

In this work, a novel conjugate of ractopamine and bovine serum albumin (RAC–BSA) has been developed via the Mannich reaction, with a mole coupling ratio for RAC–BSA of 9:1. The proposed conjugation method provides a simple and one-step method with the use of fewer reagents compared with other conjugation methods for competitive immunoassays. RAC–BSA conjugation was used to fabricate a competitive lateral flow strip test for RAC detection in animal feed. For sample preparation, RAC was spiked in swine feed purchased from the local markets in Thailand, and methanol and running buffer at a volume ratio of 10:90 was used as extraction buffer. The procedures for sample preparation were completed within 25 min. Under optimal conditions, the limit of detection (LOD), assessed by the naked eye within 5 min, was found to be 1 ng/g. A semi-quantitative analysis was also conducted using a smart phone and computer software, with a linearity of 0.075–0.750 ng/g, calculated LOD of 0.10 ng/g, calculated limit of quantitation of 0.33 ng/g, and good correlation of 0.992. The recoveries were found in the range of 96.4%–103.7% with a relative standard deviation of 2.5%–3.6% for intra- and inter-assays. Comparison of the results obtained by the strip test with those obtained by enzyme-linked immunosorbent assay had a good agreement in terms of accuracy. Furthermore, this strip test exhibited highly specific RAC detection without cross reactivity with related compounds. Therefore, the RAC–BSA conjugation via the Mannich reaction can be accepted as a one-step and easy conjugation method and applied to the competitive lateral flow strip test.

SÉLECTION CITATIONS
Détails de la recherche