Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtre
Ajouter des filtres








Gamme d'année
1.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 97-100, 2017.
Article Dans Chinois | WPRIM | ID: wpr-823267

Résumé

Objective @#To explore the effects of mouth floor approach intubation in the treatment of jaw fracture combined with skull base injury.@*Methods @#From Jan. 2014 to Oct. 2015, 7 cases of jaw fracture combined with skull base injury were selected from Medical center of Stomatology, Foshan Hospital of Traditional Chinese Medicine (FSTCM). All cases were treated with mouth floor approach intubation, because they were not suitable to be given the oral or nasal intubation anesthesia. @*Results @#All the patients healed well after operation, and there was no tube accident or other complications.@*Conclusions@# For patients of jaw fracture combined with skull base injury, the mouth floor approach intubation could be recommended as a supplementary choice for traditional intubation methods.

2.
Clinics ; 71(8): 449-454, Aug. 2016. tab
Article Dans Anglais | LILACS | ID: lil-794628

Résumé

OBJECTIVES: Pathological complete response has shown a better prognosis for patients with locally advanced rectal cancer after preoperative chemoradiotherapy. However, correlations between post-chemoradiotherapy clinical factors and pathologic complete response are not well confirmed. The aim of the current study was to identify post-chemoradiotherapy clinical factors that could serve as indicators of pathologic complete response in locally advanced rectal cancer. METHODS: This study retrospectively analyzed 544 consecutive patients with locally advanced rectal cancer treated at Sun Yat-sen University Cancer Center from December 2003 to June 2014. All patients received preoperative chemoradiotherapy followed by surgery. Univariate and multivariate regression analyses were performed to identify post-chemoradiotherapy clinical factors that are significant indicators of pathologic complete response. RESULTS: In this study, 126 of 544 patients (23.2%) achieved pathological complete response. In multivariate analyses, increased pathological complete response rate was significantly associated with the following factors: post-chemoradiotherapy clinical T stage 0-2 (odds ratio=2.098, 95% confidence interval=1.023-4.304, p=0.043), post-chemoradiotherapy clinical N stage 0 (odds ratio=2.011, 95% confidence interval=1.264-3.201, p=0.003), interval from completion of preoperative chemoradiotherapy to surgery of >7 weeks (odds ratio=1.795, 95% confidence interval=1.151-2.801, p=0.010) and post-chemoradiotherapy carcinoembryonic antigen ≤2 ng/ml (odds ratio=1.579, 95% confidence interval=1.026-2.432, p=0.038). CONCLUSIONS: Post-chemoradiotherapy clinical T stage 0-2, post-chemoradiotherapy clinical N stage 0, interval from completion of chemoradiotherapy to surgery of >7 weeks and post-chemoradiotherapy carcinoembryonic antigen ≤2 ng/ml were independent clinical indicators for pathological complete response. These findings demonstrate that post-chemoradiotherapy clinical factors could be valuable for post-operative assessment of pathological complete response.


Sujets)
Humains , Mâle , Femelle , Enfant , Adolescent , Adulte , Adulte d'âge moyen , Sujet âgé , Sujet âgé de 80 ans ou plus , Jeune adulte , Adénocarcinome/anatomopathologie , Adénocarcinome/thérapie , Chimioradiothérapie/méthodes , Tumeurs du rectum/anatomopathologie , Tumeurs du rectum/thérapie , Modèles logistiques , Analyse multifactorielle , Traitement néoadjuvant/méthodes , Stadification tumorale , Odds ratio , Période postopératoire , Période préopératoire , Valeurs de référence , Études rétrospectives , Facteurs temps , Résultat thérapeutique
3.
Clinics ; 71(5): 264-270, May 2016. tab, graf
Article Dans Anglais | LILACS | ID: lil-782834

Résumé

OBJECTIVES: This study aimed to evaluate the safety and efficacy of a new nickel-titanium shape memory alloy compression anastomosis ring, NiTi CAR 27, in constructing an anastomosis for colorectal cancer resection compared with conventional staples. METHODS: In total, 234 consecutive patients diagnosed with colorectal cancer receiving sigmoidectomy and anterior resection for end-to-end anastomosis from May 2010 to June 2012 were retrospectively analyzed. The postoperative clinical parameters, postoperative complications and 3-year overall survival in 77 patients using a NiTi CAR 27 compression ring (CAR group) and 157 patients with conventional circular staplers (STA group) were compared. RESULTS: There were no statistically significant differences between the patients in the two groups in terms of general demographics and tumor features. A clinically apparent anastomotic leak occurred in 2 patients (2.6%) in the CAR group and in 5 patients (3.2%) in the STA group (p=0.804). These eight patients received a temporary diverting ileostomy. One patient (1.3%) in the CAR group was diagnosed with anastomotic stricture through an electronic colonoscopy after 3 months postoperatively. The incidence of postoperative intestinal obstruction was comparable between the two groups (p=0.192). With a median follow-up duration of 39.6 months, the 3-year overall survival rate was 83.1% in the CAR group and 89.0% in the STA group (p=0.152). CONCLUSIONS: NiTi CAR 27 is safe and effective for colorectal end-to-end anastomosis. Its use is equivalent to that of the conventional circular staplers. This study suggests that NiTi CAR 27 may be a beneficial alternative in colorectal anastomosis in Chinese colorectal cancer patients.


Sujets)
Humains , Mâle , Femelle , Adulte , Adulte d'âge moyen , Sujet âgé , Sujet âgé de 80 ans ou plus , Jeune adulte , Côlon sigmoïde/chirurgie , Anastomose chirurgicale/instrumentation , Tumeurs colorectales/chirurgie , Période postopératoire , Agrafeuses chirurgicales/effets indésirables , Anastomose chirurgicale/effets indésirables , Anastomose chirurgicale/méthodes , Études rétrospectives , Résultat thérapeutique , Conception d'appareillage , Sécurité du matériel/instrumentation , Alliages , Désunion anastomotique/étiologie
SÉLECTION CITATIONS
Détails de la recherche