Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtre
1.
Chinese Journal of Medical Instrumentation ; (6): 377-382, 2023.
Article Dans Chinois | WPRIM | ID: wpr-982249

Résumé

Dynamic multi-leaf collimator, which has the function of radiation beam shaping, is a key executive component of tumor precise radiotherapy, and plays a core role in improving the accuracy, efficiency and quality of radiotherapy. A new type of collimator leaf end structure with circular arc and plane combination was studied, and collimator penumbra performance analysis model combining analytical expression and graphic analysis was developed. The influence of leaf end structure on penumbra was analyzed quantitatively, and a set of three-dimensional structure design of dynamic multi-leaf collimator was completed. The feasibility of the structural design and analysis model was verified through experimental measurements.


Sujets)
Humains , Planification de radiothérapie assistée par ordinateur/méthodes , Accélérateurs de particules , Tumeurs , Dosimétrie en radiothérapie
2.
Chinese Journal of Medical Instrumentation ; (6): 360-364, 2023.
Article Dans Chinois | WPRIM | ID: wpr-982246

Résumé

Advanced radiotherapy technology enables the dose to more accurately conform to the tumor target area of the patient, providing accurate treatment for the patient, but the gradient of the patient's radiation dose at the tumor edge is getting larger, which putting forward higher requirements for radiotherapy dose verification. The dose verification system software KylinRay-Dose4D can verify the patient's pre-treatment plan and the in vivo/on-line dose during the patient's treatment, providing important reference for the physicist to modify the radiotherapy plan and ensuring that the patient receives accurate treatment. This study introduces the overall design and key technologies of KylinRay-Dose4D, and tests the pre-treatment plan dose checking calculation and 2D/3D dose verification through clinical cases. The test results showed that the 2D/3D gamma pass rate (3 mm/3%) of KylinRay-Dose4D reconstructed dose compared with TPS plan dose and measured dose is larger than 95%, which indicating that the reconstructed dose of KylinRay-Dose4D meets the requirement of clinical application.


Sujets)
Humains , Dosimétrie en radiothérapie , Planification de radiothérapie assistée par ordinateur/méthodes , Radiothérapie conformationnelle avec modulation d'intensité/méthodes , Logiciel , Tumeurs , Fantômes en imagerie , Radiométrie/méthodes
3.
Chinese Journal of Medical Instrumentation ; (6): 7-10, 2018.
Article Dans Chinois | WPRIM | ID: wpr-774482

Résumé

KylinRay-IMRT is the advanced radiotherapy treatment planning module of accurate radiotherapy system (KylinRay) aiming to provide accurate and efficient plan design platform. In this paper the system design, main functions and key technologies of KylinRay-IMRT were introduced. KylinRay-IMRT supports three dimensional conformal radiotherapy (3D-CRT), intensity modulated radiotherapy (IMRT) and many other types of treatment plan design with function modules including patient data management, image registration and fusion, image contouring, image three dimensional reconstruction and visualization, three dimensional conformal radiotherapy planning, intensity modulated radiotherapy planning, plan evaluation and comparison, and report print. KylinRay-IMRT has been tested by the national standard YY/T 0889-2013, the results showed that the performance of KylinRay-IMRT can fully meet the standard requirements.


Sujets)
Humains , Dosimétrie en radiothérapie , Planification de radiothérapie assistée par ordinateur , Radiothérapie conformationnelle , Radiothérapie conformationnelle avec modulation d'intensité , Tomodensitométrie
SÉLECTION CITATIONS
Détails de la recherche