Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 6 de 6
Filtre
Ajouter des filtres








Gamme d'année
1.
Chinese Journal of Rheumatology ; (12): 264-267, 2020.
Article Dans Chinois | WPRIM | ID: wpr-868202

Résumé

Objective:To summary the clinical features of 8 cases with ankylosing spondylitis (AS) complicated with systemic lupus erythematosus (SLE).Methods:This study was conducted retrospectively from January 2007 to November 2018. Eight patients with AS complicated with SLE who were admitted to Foshan Hospital of TCM were analyzed. Bath ankylosing spondylitis disease activity index (BASDAI) was compared using t-test. Results:Four patients were female. The mean age was (31±14) years, ranged from 16 to 59 years. The average disease duration of AS was (27±30) months(ranging from 4 to 144 months). The average disease of duration SLE was (69±51) months (ranging from 1 to 80 months). All patients was human lymphocyte antigen (HLA)-B27 positive. SLE-related organ involvement included kidney in 5 cases, leukocytopenia in 8 cases, arthralgia in 6 cases, nervous system in 1 case and skin rash in 3 cases. Renal biopsy were performed in 3 patients. And 2 cases were class Ⅲ+Ⅴ lupus nephritis, another one was class Ⅳ+Ⅴ lupus nephritis.Conclusion:AS may complicated with SLE. Some drugs may be able to active the potential SLE, which should be differentiated from drug-related lupus.

2.
Chinese Journal of Rheumatology ; (12): 446-451, 2018.
Article Dans Chinois | WPRIM | ID: wpr-707874

Résumé

Objective To investigate the reliability and validity of the medical outcomes by applying short form-36 (SF-36) in evaluating gout patients’ health related quality of life (HRQOL).Methods Gout patientswere enrolled between March 2016 and June 2016 in Foshan Hospital of Traditional Chinese Medicine.Patients completed the SF-36 questionnaire.Summary scores,physical component summary (PCS) and mental component summary (MCS) were calculated by summing factor-weighted scores across all 8 subscales,with factor weights derived from general population.The indicators of reliability and validity included internal consistency,test-retest reliability,structural and discriminant validity,ceiling and floor effect.Results Totally 306 patients were enrolled.The internal consistency test showed that the Cronbach α coefficients ranged from 0.782 to 0.822,and the test-retest reliability coefficients ranged from 0.720 to 0.986 (P<0.01).Structural validity analysis showed that there were two items whose eigenvalues were greater than one with the cumulative contribution rate of 66.1%.The discriminant validity analysis found that patients with more numbers of tophi,higher frequency of flare,multi-arthrosis involved and more complications had less scores of PCS and MCS (P<0.05).There was a high ceiling effect on physiological function and a higher ceiling and floor effect on role limitation and emotional function caused hy impaired physical health.Conclusion The SF-36 can be used for the assessment of HRQOL in Chinese gout patients but disease specific questionnaire are warranted.

3.
Chinese Journal of Medical Imaging ; (12): 259-263, 2017.
Article Dans Chinois | WPRIM | ID: wpr-609176

Résumé

Purpose To evaluate the clinical value of triple-rule-out (TRO) computed tomographic angiography using adaptive prospective ECG triggering for chest pain patients.Materials and Methods Sixty patients with chest pain were prospectively collected and randomly divided into group A and group B:group A (n=30) performed prospectively gated axial scan and group B (n=30) performed retrospectively gated helical scan.The vascular density,noise and muscle density of the vessels including aorta,pulmonary artery,coronary artery between the two groups were measured and analyzed.The vascular density/noise ratio,contrast noise ratio and effective dose (ED) between the two groups were calculated.The image quality and scanning radiation dose were compared between the two groups.Results There was no significant difference in the image quality of aorta,pulmonary artery and coronary artery between group A and group B (P>0.05).The ED in group A was lower than that in group B [(5.90±2.10) mSv vs (11.31 ± 2.12) mSv,P<0.01].Conclusion The technique of TRO computed tomographic angiography triggered by adaptive prospective ECG can significantly reduce the radiation dose while ensuring image quality.

4.
Chinese Journal of Medical Imaging Technology ; (12): 428-432, 2017.
Article Dans Chinois | WPRIM | ID: wpr-608748

Résumé

Objective To explore the application value of CT perfusion imaging for predicting the tiny lymph nodes metastasis and micrometastasis of squamous cell carcinoma in cervix after neoadjuvant chemotherapy.Methods The clinical data and CT perfusion parameters of 46 patients with cervical squamous cell carcinoma who underwent neoadjuvant chemotherapy followed by surgery were enrolled in the study.Based on the surgical pathology findings and short-term follow up,the cases were divided into without tiny lymph nodes metastasis (short axle diameter of lymph nodes<10 mm) group (n=32) and with tiny lymph nodes metastasis group (n=14).All perfusion data were analyzed retrospectively and the diagnostic value were investigated.Results Blood flow (BF),blood volume (BV) and the maximum diameter of tumor per-chemotherapy in with tiny lymph nodes metastasis group were higher than those in without tiny lymph nodes metastasis group (all P<0.05).The differences of the maximum diameter of tumor after chemotherapy,permeability,time to peak (TTP) between two groups were not statistically significant (all P>0.05).Multivariate Logistic regression analysis showed BF and the maximum diameter of tumor per-chemotherapy were independent predictors of the tiny lymph nodes metastasis in cervix after neoadjuvant chemotherapy.ROC showed BF (AUC=0.86,P<0.001,95%CI [0.75,0.96]) had higher predictive value than maximum diameter of tumor per-chemotherapy (AUC=0.70,P=0.02,95 % CI [0.54,0.88]).Conclusion CT perfusion imaging shows the significant predictive value for the tiny lymph nodes metastasis of squamous cell carcinoma in cervix after neoadjuvant chemotherapy.

5.
Chinese Journal of Cardiology ; (12): 415-418, 2017.
Article Dans Chinois | WPRIM | ID: wpr-808671

Résumé

Objective@#To analyze the normal value of the iodine content in the left ventricular myocardium of healthy subjects and to observe if there is a segmental differences on iodine distribution by using the second generation dual-source dual-energy computed tomography myocardial first perfusion imaging.@*Methods@#In this retrospective study, 42 healthy subjects, who admitted to our department between January to June 2016, with normal second generation dual-source dual-energy computed tomography and coronary CT angioghphy (CTA), electrocardiogram (ECG) results, normal cardiac, hepatic, renal function, normal myocardial enzymes results were enrolled, data from 38 out of 42 subjects with satisfactory image quality were analyzed using Siemens Dual Energy-Heart PBV image processing software.In accordance with the standards of the American Heart Association myocardial 17 fractionation method, content of iodine was measured at different segmental left ventricular myocardium and aorta (left coronary artery from the opening level). The standardized containing iodine value (nIC) was calculated.@*Results@#The iodine content of left ventricular myocardium in normal subjects was 3.1-7.8 mg/ml.The nIC of myocardium from 1st to 17th segments was 0.28±0.06, 0.31±0.07, 0.30±0.07, 0.30±0.04, 0.28±0.04, 0.29±0.05, 0.29±0.01, 0.30±0.07, 0.31±0.07, 0.27±0.06, 0.28±0.08, 0.28±0.07, 0.29±0.08, 0.31±0.07, 0.27±0.06, 0.29±0.06 and 0.21±0.07, respectively.The nIC of the 17th segment was the lowest and was significantly lower than in other segments (all P<0.05), the nIC was similar among the rest 16 segments (all P>0.05).@*Conclusion@#The normal iodine content range in left ventricle myocardium is 3.1-7.8 mg/ml, and the lowest iodine content is detected in the apex and which is significantly lower than the other left ventricular segments.

6.
Journal of Practical Radiology ; (12): 1739-1741, 2014.
Article Dans Chinois | WPRIM | ID: wpr-459780

Résumé

Objective To investigate the difference of colon length between patients with intractable constipation and normal peo-ple.Methods 40 patients with intractable constipation and 35 cases of normal control group received air enema CT scan,post-pro-cessing techniques-curved planar reformation and volume rendering were used to measure the length of colon.Results Colon length of normal people and constipation patients were (1 230±33)mm and (1 605±47)mm,respectively.There was significant difference between normal people and constipation patients (t=163,P=0.015).Conclusion CT air enema technique can be used to measure the length of colon obj ectively for diagnosing and treating redundant colon.

SÉLECTION CITATIONS
Détails de la recherche