Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtre
Ajouter des filtres








Gamme d'année
1.
China Medical Equipment ; (12): 133-136, 2016.
Article Dans Chinois | WPRIM | ID: wpr-494715

Résumé

Most of the transfusion adult outpatients are old people with chronic disease, and theirsmall blood vessels become less elastic with age. They need long course and repeated localised puncture site. On the base of that fact, the author describes the 5.5gauge scalp acupuncture and 7 gauge scalp acupuncture about their use on the patients. The 5.5 gauge scalp acupuncture is smaller and shorter, so it has the advantage of high success ratio and it is easier to be fixed. Additionally, the transfusion speed is easy to be controlled, which reduces the ratios of transfusion reaction and adverse drug reactions. The pinhole is small and can be healed faster. The congestion around the puncture location is less than that of the 7 scalp acupuncture. It can alleviate the pain for patients and increase satisfaction. To sum up, the 5.5 gauge scalp acupuncture should be used widely as we allocate“people oriented”and“All for the patients”.

2.
International Journal of Laboratory Medicine ; (12): 503-505, 2015.
Article Dans Chinois | WPRIM | ID: wpr-462126

Résumé

Objective To develop improved enzymatic creatinine(Cr)assay reagents (self-R&D),and to investigate their appli-cation on serum detection by comparing with imported commercial Cr reagents(enzymatic Cr reagents from Toyobo)Methods En-zymatic method was used to evaluate the effect of every component and different concentrations of reagents on Cr assay by detecting the alteration of absorbance of Cr before or after the reaction.Meanwhile,the blank absorbance and analysis sensitivity of self-R&D and imported reagents,the technical indicators of precision,linearity,as well as method comparison of self-R&D reagents,were de-tected on the same automatic biochemical analyzer.Results The blank absorbance of self-R&D reagents was 0.009,and the detec-tion sensitivity was 0.13,better than that of imported Cr reagents.The coefficient of variation (CV)of high and low values of ser-um of self-R&D reagents were 1.5%,and 1.1%,respectively.The linear range was 0-2 850 μmol/L and the method comparison result was Y =0.98X +1.15 (r =0.999).The expected bias was less than the allowable error region.Using relative deviation≥10% as an index to evaluate the existence of significant interference,it shows that 35 mmol/L of creatine,3.42 mmol/L of biliru-bin,0.03 g/L of vitamin C,5 g/L of hemoglobin and 1450 FTU chyle in both low and high concentration serum samples did not interfere with the test result.Conclusion The quality of self-R&D reagents was good,and there was a good relativity between self-R&D reagents and imported Cr reagents with excellent quality.This indicates the self-R&D reagents could satisfy the application requirements of the clinics.

3.
Journal of Audiology and Speech Pathology ; (6)1998.
Article Dans Chinois | WPRIM | ID: wpr-520940

Résumé

Objective To afford a clinical reference for applications of TIP-300 insert earphone in accordance with its difference in inter-aural attenuation from the telephonics TDH-50P supra-aural earphone.Methods Detections of inter-aural attenuation for pure tone air conduction were performed on the enrolled individuals combined with unilateral anakusis and one normal ear (male and female were 13 and 22 respectively) by GSI61 audiometer?TIP-300 insert earphone or telephonics TDH-50Psupra-aural earphone.Results Inter-aural attenuation differences were significant ( P

SÉLECTION CITATIONS
Détails de la recherche