Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 1 de 1
Filtrer
Plus de filtres








Gamme d'année
1.
Clinics ; 63(2): 237-244, 2008. graf, tab
Article de Anglais | LILACS | ID: lil-481054

RÉSUMÉ

INTRODUCTION: Studies comparing high frequency oscillatory and conventional ventilation in acute respiratory distress syndrome have used low values of positive end-expiratory pressure and identified a need for better recruitment and pulmonary stability with high frequency. OBJECTIVE: To compare conventional and high frequency ventilation using the lower inflection point of the pressure-volume curve as the determinant of positive end-expiratory pressure to obtain similar levels of recruitment and alveolar stability. METHODS: After lung lavage of adult rabbits and lower inflection point determination, two groups were randomized: conventional (positive end-expiratory pressure = lower inflection point; tidal volume=6 ml/kg) and high frequency ventilation (mean airway pressures= lower inflection point +4 cmH2O). Blood gas and hemodynamic data were recorded over 4 h. After sacrifice, protein analysis from lung lavage and histologic evaluation were performed. RESULTS: The oxygenation parameters, protein and histological data were similar, except for the fact that significantly more normal alveoli were observed upon protective ventilation. High frequency ventilation led to lower PaCO2 levels. DISCUSSION: Determination of the lower inflection point of the pressure-volume curve is important for setting the minimum end expiratory pressure needed to keep the airways opened. This is useful when comparing different strategies to treat severe respiratory insufficiency, optimizing conventional ventilation, improving oxygenation and reducing lung injury. CONCLUSIONS: Utilization of the lower inflection point of the pressure-volume curve in the ventilation strategies considered in this study resulted in comparable efficacy with regards to oxygenation and hemodynamics, a high PaCO2 level and a lower pH. In addition, a greater number of normal alveoli were found after protective conventional ventilation in an animal model of acute respiratory distress syndrome.


Sujet(s)
Animaux , Lapins , Modèles animaux de maladie humaine , Ventilation à haute fréquence , Ventilation à pression positive/méthodes , , Analyse de variance , Gazométrie sanguine , Lavage bronchoalvéolaire , Loi du khi-deux , Ventilation à haute fréquence/effets indésirables , Compliance pulmonaire , Poumon/anatomopathologie , Ventilation à pression positive/effets indésirables , Répartition aléatoire , /anatomopathologie , /physiopathologie , /thérapie , Facteurs temps , Volume courant/physiologie
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE