1.
Rev. Hosp. Clin. Fac. Med. Univ. Säo Paulo ; 54(6): 181-6, Nov.-Dec. 1999. ilus, tab, graf
Article Dans Anglais | LILACS | ID: lil-260494

Résumé

Cylindrical specimens of bone measuring 15 mm in diameter were obtained from the lateral cortical layer of 10 pairs of femurs and tibias. A central hole 3.2 mm in diameter was drilled in each specimen. The hole was tapped, and a 4.5 mm cortical bone screw was inserted from the outer surface. The montage was submitted to push-out testing up to a complete strip of the bone threads. The cortical thickness and rupture load were measured, and the shear stress was calculated. The results were grouped according to the bone segment from which the specimen was obtained. The results showed that bone cortex screw holding power is dependent on the bone site. Additionally, the diaphyseal cortical bone tissue is both quantitatively and qualitatively more resistant to screw extraction than the metaphyseal tissue.


Sujets)
Vis orthopédiques , Fémur/physiologie , Tibia/physiologie , Diaphyse/traumatismes , Diaphyse/chirurgie , Fémur/traumatismes , Fémur/chirurgie , Résistance à la traction , Tibia/traumatismes , Tibia/chirurgie
2.
Rev. bras. ortop ; 29(4): 211-7, abr. 1994. ilus, tab
Article Dans Portugais | LILACS | ID: lil-203421

Résumé

Os autores estudaram experimentalmente cinco modelos de osteossíntese, [1) placas e parfusos; 2) duas cerclagens intra-ósseas perpendiculares; 3) dois fios de Kirschner associados à cerclagem em oito; 4) dois fios de Kirschner cruzados; 5) dois fios de Kirschner associados à cerclagem externa] e um grupo controle (6), realizadas em metacarpianos humanos secos submetidos à força de flexäo. Concluíram que o tipo de ostessíntese mais rígida foi o do grupo 1 (placas e parafusos dorsais) e que o grupo 4 (dois fios de Kirschner cruzados) foi o que teve o pior desempenho global.


Sujets)
Humains , Ostéosynthèse interne/méthodes , Métacarpe/chirurgie , Cadavre , Métacarpe/traumatismes , Résistance à la traction
3.
Rev. bras. ortop ; 29(4): 221-5, abr. 1994. tab, ilus
Article Dans Portugais | LILACS | ID: lil-203423

Résumé

Os autores estudaram experimentalmente 26 ossos semilunares de 13 cadáveres frescos, analisando medidas antropométricas e submetendo-os a ensaios de compressäo para verificar sua resistência. Obtiveram valores de resistência variando de 41 a 200kgf, com média de 102,1kgf, e correlacionaram com as medidas antropomêtricas.


Sujets)
Humains , Mâle , Femelle , Adulte , Adulte d'âge moyen , Os lunatum/physiologie , Cadavre , Résistance à la compression , Os lunatum/anatomie et histologie
5.
Rev. bras. ortop ; 26(6): 201-4, jun. 1991. ilus, tab
Article Dans Portugais | LILACS | ID: lil-116136

Résumé

Os autores estudaram em modelo experimental, em vertebras de cäes, a funçäo dos ligamentos alares e transverso na estabilidade entre o atlas e o áxis. Com base nos testes biomecânicos realizados, concluem que a resistência dos ligamentos alares e transverso säo equivalentes e proporcionais e que a ruptura do ligamento transverso só foi obtida nos ensaios em flexocompressäo, enquanto que a ruptura dos alares foi obtida em todos os mecanismos simulados


Sujets)
Animaux , Chiens , Ligaments/physiologie , Vertèbres cervicales/traumatismes , Atlas (publication) , Axis , Rupture , Résistance à la traction
6.
Rev. bras. ortop ; 26(5): 157-60, maio 1991. ilus, tab
Article Dans Portugais | LILACS | ID: lil-116144

Résumé

Foram testados oito acetábulos de cadáveres frescos, comparando-se sua resistência frente à força axial, com utilizaçäo de rede metálica em apenas quatro acetábulos. Houve aumento significativo da resistência no conjunto que empregou rede metálica


Sujets)
Humains , Mâle , Adulte , Adulte d'âge moyen , Acétabulum/chirurgie , Filet chirurgical , Sujet âgé de 80 ans ou plus , Acier inoxydable , Contrainte mécanique
7.
Rev. bras. ortop ; 25(11/12): 395-8, nov.-dez. 1990. tab
Article Dans Portugais | LILACS | ID: lil-92507

Résumé

Os autores estudaram experimentalmente, em vértebras de cäes, a resistência dos complexos anterior, médio e posterior do segmento toracolombar da coluna à traçäo. Concluem que o complexo ligamentar anterior foi o mais resistente, vindo a seguir o complexo ligamentar médio


Sujets)
Chiens , Animaux , Mâle , Femelle , Rachis , Traction , Phénomènes biomécaniques , Vertèbres cervicales , Ligaments
8.
Rev. bras. ortop ; 25(10): 373-6, out. 1990. tab
Article Dans Portugais | LILACS | ID: lil-92501

Résumé

Foi analisado o comportamento dos anéis do aparelho Ilizarov com 130, 160 e 200mm de diâmetro sob carga de compressäo, montado com fios de Kirschner de 1,5mm, com e sem tensäo, dobrados ou näo, e sobre três ou quatro apoios. Observou-se perda da estabilidade em anéis de maior diâmetro e em anéis sobre três apoios. O dobramento da extremidade dos fios näo melhorou a fixaçäo, mas permitiu identificar o início do escorregamento. Observou-se também comportamento diferente da fixaçäo dos fios nos parafusos com orifício central e fenda lateral


Sujets)
Allongement osseux/instrumentation , Fils métalliques , Résistance à la traction
9.
Rev. bras. ortop ; 25(7): 243-7, jul. 1990. ilus, tab
Article Dans Portugais | LILACS | ID: lil-129236

Résumé

Com o objetivo de se determinar a resistência das diversas regiöes da superfície articular, estudaram-se 15 joelhos de cadáveres frescos. Foram feitos ensaios de penetraçäo em sete diferentes pontos confrontantes da tíbia e do fêmur. Os resultados mostraram que a resistência do côndilo medial da tíbia é a maior, enquanto a do côndilo lateral é a menor. No fêmur isso näo foi observado; entretanto, a média de resistência da tíbia é igual à do fêmur e a profundidade da camada esponjosa é mais fina e superficial na tíbia que no fêmur


Sujets)
Humains , Adulte , Adulte d'âge moyen , Fémur/physiologie , Résistance à la traction , Tibia/physiologie , Articulation du genou/physiologie
10.
Rev. bras. ortop ; 25(6): 197-201, jun. 1990. ilus, tab
Article Dans Portugais | LILACS | ID: lil-127383

Résumé

Pelo estudo de 20 joelhos de cadáveres frescos determinou-se näo haver proporcionalidade entre as características mecânicas do ligamento cruzado anterior e do terço central do tendäo patelar. A resistência do ligamento cruzado anterior é proporcional ao tamanho do joelho e o mesmo näo acontece com a porçäo central do tendäo patelar. A resistência das estruturas estudadas näo se altera com a idade. Outros parâmetros foram estuddos e inter-relacionados


Sujets)
Humains , Mâle , Femelle , Ligament croisé antérieur/physiologie , Ligament patellaire/physiologie , Phénomènes biomécaniques , Analyse de régression
11.
Folha méd ; 100(5/6): 165-70, maio-jun. 1990. ilus, tab
Article Dans Portugais | LILACS | ID: lil-113499

Résumé

Em 96 metacarpianos de cadáveres frescos, foram comparados experimentalmente três modelos de osteossíntese, (1) cerclagens intra-ósseas perpendiculares, (2) dois fios de Kirschner rosqueados cruzados e (3) dois fios de Kirschner lisos cruzados. Para a análise dos resultados foram agrupados em dois conjuntos: 2§ e 3§ metacarpianos e 4§ e 5§ metacarpianos. Estudados os valores da carga no limite de proporcionalidade, observou-se que a síntese 2 (dois fios de Kirschner rosqueados cruzados) é mais resistente que a síntese 3 (dois fios de Kirschner lisos cruzados). Analisaram-se também os valores da constante de proporcionalidade, verificando-se que a síntese 1 (cerclagens intra-ósseas perpendiculares) é mais rígida do que as sínteses 2 e 3


Sujets)
Humains , Ostéosynthèse interne/méthodes , Métacarpe/traumatismes , Fils métalliques
12.
Rev. bras. ortop ; 25(1/2): 26-30, jan.-fev. 1990. ilus, tab
Article Dans Portugais | LILACS | ID: lil-85291

Résumé

Estudamos a variaçäo das propriedades físico-mecânicas: resistência a deformaçäo, área de secçäo, densidade óssea e suas interdependências ao longo da diáfise da ulna humana, quando submetida a ensaios de compressäo axial. A resistência óssea variou ao longo do comprimento da ulna, ao contrário da deformaçäo, que se manteve constante. A tensäo máxima média da diáfise ulnar fresca foi de 1.511Kgf/cm**2


Sujets)
Adulte , Humains , Ulna , Résistance à la traction
13.
Rev. bras. ortop ; 24(11/12): 393-6, nov.-dez. 1989. ilus, tab
Article Dans Portugais | LILACS | ID: lil-129212

Résumé

Os autores apresentam os resultados de 21 casos de hálux valgo tratados pela técnica de Wilson e analisam a influência do ângulo da osteotomia, os ângulos pré e pós-operatórios, metatarsofalangiano do halúx e intermetatarso do I e II raios. Concluem preconizando um ângulo de osteotomia sempre menor que 45º


Sujets)
Humains , Mâle , Femelle , Adulte , Adulte d'âge moyen , Hallux valgus/chirurgie , Ostéotomie , Hallux valgus
14.
Rev. bras. ortop ; 24(9): 327-9, set. 1989. ilus
Article Dans Portugais | LILACS | ID: lil-83714

Résumé

Os autores realizaram estudo experimental da estabilidade do segmento toracolombar da coluna. Foram utilizadas 15 colunas obtidas de cadáveres frescos, sendo testados os segmentos de T11 a L2. Após teste mecânico, concluiu-se que as fraturas com encunhamento maior que 40% devem ser consideradas instáveis


Sujets)
Adolescent , Adulte , Humains , Mâle , Autopsie , Dissection , Ligaments articulaires , Rachis/anatomie et histologie , Essais cliniques comme sujet
15.
Rev. bras. ortop ; 24(5): 139-44, 1989. ilus, tab
Article Dans Portugais | LILACS | ID: lil-80075

Résumé

Estudamos comparativamente as propriedades mecânicas de quatro grupos de pericárdios bovinos: fresco, congelado e dois tipos fixados em glutaraldeído e conservados em formaldeído obtidos comercialmente. Verficamos a possibilidade de eventual utilizaçäo como substituto biológico de ligamentos e tendöes. Há evidências de que os tratamentos químicos a que säo submetidos os pericárdios comerciais melhoram suas qualidades mecânicas


Sujets)
Bovins , Animaux , Phénomènes biomécaniques , Bioprothèse , Péricarde/physiologie , Élasticité , Formaldéhyde , Congélation , Glutaraldéhyde
16.
Rev. bras. ortop ; 23(8): 235-8, ago. 1988. ilus, tab
Article Dans Portugais | LILACS | ID: lil-68954

Résumé

Os autores comparam, através de modelo experimental em vértebras da cäes, o comportamento mecânico da substituiçäo do corpo vertebral por cilindros de metilmetacrilato simples e com fio metálico rosqueado no seu eixo longitudinal. Concluem que ambos os modelos testados atendem às cargas de compressäo axial, sendo que o modelo com fio metálico rosqueado é mais estável


Sujets)
Chiens , Animaux , Méthacrylates de méthyle , Vertèbres cervicales/chirurgie , Phénomènes biomécaniques , Modèles biologiques
18.
Rev. bras. ortop ; 23(5): 136-40, maio 1988. tab, ilus
Article Dans Portugais | LILACS | ID: lil-59276

Résumé

Foram avaliados pinos de Küntscher de diâmetro nominal 11 e 12mm, procedentes de quatro diferentes fabricantes, os quais foram submetidos a testes de flexäo simples biapoiada, dureza e metrologia. Os resultados obtidos säo comentados e feitas consideraçöes a respeito


Sujets)
Clous orthopédiques
19.
Rev. bras. ortop ; 22(10): 297-300, nov.-dez. 1987. ilus, tab
Article Dans Portugais | LILACS | ID: lil-45054

Résumé

Foram comparados corpos de prova de gesso e de material sintético através de ensaios mecânicos para otimizar o dimensionamento de aparelhos de imobilizaçäo confeccionados com o último. Os ensaios consistiram de compressäo lateral de corpos cilíndricos e flexäo de placas compostos com cada um dos materiais


Sujets)
Sulfate de calcium , Modèles anatomiques
20.
Rev. bras. ortop ; 22(5): 139-43, jun. 1987. tab, ilus
Article Dans Portugais | LILACS | ID: lil-41803

Résumé

Analisa-se o comportamento, quanto à resistência à compressäo e à dissipaçäo de calor, de corpos de prova de 30mm x 20mm, compostos de cimento acrílico somente, e de cimento acrílico associado a esferas Ý = 5mm) e cilindros (15mm X 10mm) de polietileno e cimento acrílico


Sujets)
Résines acryliques , Ciments osseux , Orthopédie , Polyéthylènes