Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
Ajouter des filtres








Gamme d'année
1.
Western Pacific Surveillance and Response ; : 27-30, 2017.
Article Dans Anglais | WPRIM | ID: wpr-6810

Résumé

Arboviruses continue to pose serious public health threats in the World Health Organization (WHO) Western Pacific Region. As such, laboratories need to be equipped for their accurate detection. In 2011, to ensure test proficiency, the WHO Regional Office for the Western Pacific piloted an external quality assessment (EQA) programme for arbovirus diagnostics. By 2016, it had grown into a global programme with participation of 96 laboratories worldwide, including 25 laboratories from 19 countries, territories and areas in the Region. The test performance of the 25 laboratories in the Region in 2016 was high with 23 (92%) reporting correct results in all specimens for dengue and chikungunya viruses. For Zika virus, 18 (72%) of the 25 laboratories reported correct results in all specimens, while seven (28%) demonstrated at least one error. When comparing iterations of this EQA programme in the Region between 2013 and 2016, the number of participating laboratories increased from 18 to 25. The first round only included dengue virus, while the latest round additionally included chikungunya, Zika and yellow fever viruses. Proficiency for molecular detection of dengue virus remained high (83–94%) over the four-year period. The observed proficiency for arbovirus diagnostics between 2013 and 2016 is an indicator of laboratory quality improvement in the Region.

2.
Bull. W.H.O. (Online) ; 90(3): 191-199, 2012. ilus
Article Dans Anglais | AIM | ID: biblio-1259890

Résumé

Objective: To describe findings from an external quality assessment programme involving laboratories in Africa that routinely investigate epidemic-prone diseases.Methode Beginning in 2002, the Regional Office for Africa of the World Health Organization (WHO) invited national public health laboratories and related facilities in Africa to participate in the programme. Three surveys comprising specimens and questionnaires associated with bacterial enteric diseases, bacterial meningitis, plague, tuberculosis and malaria were sent annually to test participants' diagnostic proficiency. Identical surveys were sent to referee laboratories for quality control. Materials were prepared, packaged and shipped in accordance with standard protocols. Findings and reports were due within 30 days. Key methodological decisions and test results were categorized as acceptable or unacceptable on the basis of consensus feedback from referees, using established grading schemes.Findings Between 2002 and 2009, participation increased from 30 to 48 Member States of the WHO and from 39 to 78 laboratories. Each survey was returned by 64­93% of participants. Mean turnaround time was 25.9 days. For bacterial enteric diseases and meningitis components, bacterial identification was acceptable in 65% and 69% of challenges, respectively, but serotyping and antibiotic susceptibility testing and reporting were frequently unacceptable. Microscopy was acceptable for 73% of plague challenges. Tuberculosis microscopy was satisfactorily performed, with 87% of responses receiving acceptable scores. In the malaria component, 82% of responses received acceptable scores for species identification but only 51% of parasite quantitation scores were acceptable.Conclusion The external quality assessment programme consistently identified certain functional deficiencies requiring strengthening that were present in African public health microbiology laboratories


Sujets)
Afrique , Prestations des soins de santé , Infections , Laboratoires , Paludisme , Méningite , Peste , Contrôle de qualité , Tuberculose
SÉLECTION CITATIONS
Détails de la recherche