Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
Ajouter des filtres








Gamme d'année
1.
Translational and Clinical Pharmacology ; : 22-29, 2016.
Article Dans Anglais | WPRIM | ID: wpr-165361

Résumé

Simvastatin is a lipid-lowering drug that is metabolized to its active metabolite simvastatin acid (SA). We developed and validated a sensitive liquid chromatography-tandem mass spectrometry (LC/MS/MS) method to quantitate SA in human plasma using a liquid-liquid extraction method with methanol. The protonated analytes generated in negative ion mode were monitored by multiple reaction monitoring. Using 500-mL plasma aliquots, SA was quantified in the range of 0.1-100 ng/mL. Calibration was performed by internal standardization with lovastatin acid, and regression curves were generated using a weighting factor of 1/χ2. The linearity, precision, and accuracy of this assay for each compound were validated using quality control samples consisting of mixtures of SA (0.1, 0.5, 5, and 50 ng/mL) and plasma. The intra-batch accuracy was 95.3-107.8%, precision was -2.2% to -3.7%, and linearity (r2) was over 0.998 in the standard calibration range. The chromatographic running time was 3.0 min. This method sensitively and reliably measured SA concentrations in human plasma and was successfully used in clinical pharmacokinetic studies of simvastatin in healthy Korean adult male volunteers.


Sujets)
Adulte , Humains , Mâle , Calibrage , Extraction liquide-liquide , Lovastatine , Spectrométrie de masse , Méthanol , Plasma sanguin , Protons , Contrôle de qualité , Course à pied , Simvastatine , Bénévoles
2.
Journal of Korean Society for Clinical Pharmacology and Therapeutics ; : 135-144, 2012.
Article Dans Anglais | WPRIM | ID: wpr-190983

Résumé

BACKGROUND: Letrozole is an oral non-steroidal inhibitor of the aromatase enzyme, which has proven to be a useful drug against breast cancer. METHODS: This single-dose, randomized 2 x 2 crossover study was conducted in healthy male volunteers. Participants of each sequence group (each 13 volunteers for sequence group) received, in randomized sequence, a single oral 2.5-mg dose of generic letrozole (test) or branded letrozole (reference). Each treatment period was separated by a 5-week washout period. Blood samples were collected for up to 312 hours after drug administration, and drug concentrations were determined using validated LC/MS-MS. Pharmacokinetic properties were obtained using noncompartmental analysis. Drug tolerability was assessed throughout the study, using measurements of vital signs, physical examination, clinical chemistry testing, EKG, and interviews. RESULTS: A total of 26 subjects completed the study. The geometric mean ratios (90% CI) of Cmax and AUClast were 0.92 (0.85 - 0.99) and 1.01 (0.97 - 1.04), respectively. No serious AEs were reported, and there were no clinically significant differences between test and reference groups. CONCLUSION: The findings from this study suggest bioequivalence between two formulations of letrozole in healthy male volunteers. The safety profile of two formulations had similar characteristics.


Sujets)
Humains , Mâle , Aromatase , Région mammaire , Tests de chimie clinique , Études croisées , Électrocardiographie , Nitriles , Examen physique , Équivalence thérapeutique , Triazoles , Signes vitaux
SÉLECTION CITATIONS
Détails de la recherche