RÉSUMÉ
Abstract Background: The impact of paravalvular regurgitation (PVR) following transcatheter aortic valve implantation (TAVI) remains uncertain. Objective: To evaluate the impact of PVR on mortality and hospital readmission one year after TAVI. Methods: Between January 2009 and June 2015, a total of 251 patients underwent TAVI with three different prostheses at two cardiology centers. Patients were assessed according to PVR severity after the procedure. Results: PVR was classified as absent/trace or mild in 92.0% (n = 242) and moderate/severe in 7.1% (n = 18). The moderate/severe PVR group showed higher levels of aortic calcification (22% vs. 6%, p = 0.03), higher serum creatinine (1.5 ± 0.7 vs. 1.2 ± 0.4 mg/dL, p = 0.014), lower aortic valve area (0.6 ± 0.1 vs. 0.7 ± 0.2 cm2, p = 0.05), and lower left ventricular ejection fraction (49.2 ± 14.8% vs. 58.8 ± 12.1%, p = 0.009). Patients with moderate/severe PVR had more need for post-dilatation (p = 0.025) and use of larger-diameter balloons (p = 0.043). At one year, all-cause mortality was similar in both groups (16.7% vs. 12%, p = 0.08), as well as rehospitalization (11.1% vs. 7.3%, p = 0.915). PVR grade significantly reduced throughout the first year after the procedure (p < 0.01). The presence of moderate/severe PVR was not associated with higher one-year mortality rates (HR: 0.76, 95% CI: 0.27-2.13, p = 0.864), rehospitalization (HR: 1.08, 95% CI: 0.25-4.69, p=0.915), or composite outcome (HR: 0.77, 95% CI: 0.28-2.13, p = 0.613). Conclusion: In this sample, moderate/severe PVR was not a predictor of long-term mortality or rehospitalization. (Arq Bras Cardiol. 2017; [online].ahead print, PP.0-0)
Resumo Fundamento: O impacto da regurgitação paravalvular (RPV) após implante de valva aórtica transcateter (TAVI) permanece incerto. Objetivo: Analisar o impacto da RPV na mortalidade e re-hospitalização 1 ano após o TAVI. Métodos: Entre janeiro de 2009 e junho de 2015, 251 pacientes foram submetidos ao TAVI em dois centros cardiológicos com 3 diferentes próteses. Os pacientes foram analisados de acordo com a gravidade da RPV pós-procedimento. Resultados: RPV foi classificada como ausente/mínima ou discreta em 92,0% (n=242) dos pacientes e moderada/grave em 7,1% (n = 18). Os pacientes com RPV moderada/importante apresentaram maior grau de calcificação aórtica (22,0% vs. 6,0%; p = 0,03), creatinina sérica (1,53 ± 0,71 vs. 1,18 ± 0,43 mg/dL; p = 0,01), menor área valvar aórtica (0,61 ± 0,12 vs. 0.69 ± 0,17 cm2; p = 0,05) e menor fração de ejeção do ventrículo esquerdo (49,17±14,79% vs. 58,82±12,14%; p = 0,009). Nos pacientes com RPV moderada/importante a necessidade de pós-dilatação foi maior (p = 0,025) e eventualmente com balão de diâmetro maior (p = 0,04). Ao final de 1 ano, a mortalidade por todas as causas foi similar em ambos os grupos (16,7% vs. 12,0%; p = 0,08), assim como re-hospitalização (11,1% vs. 7,3%; p = 0,91). O grau de RPV ao longo do primeiro ano reduziu progressivamente (p < 0,01). A presença de RPV moderada/importante não foi associada a maiores taxas de mortalidade em 1 ano [RR (risco relativo): 0,76; IC (intervalo de confiança) 95%: 0,27-2,13; p = 0,864)], re-hospitalização (RR: 1,08; IC 95%: 0,25-4,69; p = 0,915) ou desfecho combinado (RR: 0,77; IC 95%: 0,28-2,13; p = 0,61). Conclusões: Nesta amostra, a presença de regurgitação paravalvular moderada/importante não foi um preditor de mortalidade ou reinternação a longo prazo. (Arq Bras Cardiol. 2017; [online].ahead print, PP.0-0)
RÉSUMÉ
Introdução: O stent MGuard™, revestido por malha polimérica microscópica, tem a finalidade de reduzir a embolização distal de fragmentos durante a intervenção coronária percutânea (ICP) em enxertos de veia safena (EVS). Avaliamos os desfechos clínicos precoces e tardios de pacientes submetidos à ICP de EVS com stents MGuard™ vs. stents farmacológicos (SF). Métodos: Estudo observacional, retrospectivo, realizado em dois centros terciários, envolvendo uma coorte de pacientes com lesões em EVS, tratados de forma eletiva ou de emergência com stents MGuard™ ou SF. Resultados: Foram incluídos 271 pacientes, sendo 220 tratados com SF. O Grupo MGuard™ apresentou maior proporção de mulheres (25,5% vs. 10,5%; p=0,01), com média de idades de 65,0 ± 13,9 anos vs. 69,0 ± 9,6 anos (p = 0,06). O Grupo SF utilizou com maior frequência filtro de proteção distal (5,8% vs. 10,0%; p = 0,001). Sucesso angiográfico foi obtido na maioria dos casos (96,2% vs. 98,0%; p = 0,22). O Grupo MGuard™ teve menores taxas de eventos cardiovasculares adversos maiores (ECAM) na fase hospitalar que o Grupo SF (1,9% vs. 13,6%; p = 0,01) devido exclusivamente à menor incidência de infarto periprocedimento. Entretanto, a taxa de ECAM em 1 ano foi maior no grupo MGuard™ (14,3% vs. 4,4%; p = 0,01) à custa de maior taxa de revascularização da lesão alvo (7,1% vs. 1,3%; p = 0,048). Conclusões: A utilização de stent MGuard™ resultou em redução de eventos na fase hospitalar, porém, no longo prazo, os SF foram superiores em reduzir desfechos maiores, sobretudo a necessidade de revascularização da lesão alvo
Background: The MGuard™ stent, which has a microscopic polymer mesh coating, is intended to reduce the distal embolization of fragments during percutaneous coronary intervention (PCI) in saphenous vein grafts (SVG). This study evaluated the early and late clinical outcomes of patients undergoing PCI in SVG with MGuard™ stents vs. drugeluting stents (DES). Methods: Observational, retrospective study conducted at two tertiary centers, involving a cohort of patients with SVG lesions submitted to elective or emergency treatment with MGuard™ stents or DES. Results: A total of 271 patients were included, of whom 220 were treated with DES. The MGuard™ group had a higher proportion of women (25.5% vs. 10.5%; p = 0.01), with a mean age of 65.0 ± 13.9 years vs. 69.0 ± 9.6 years (p = 0.06). The DES group more frequently used distal protection filter (5.8% vs. 10.0%; p = 0.001). Angiographic success was attained in most cases (96.2% vs. 98.0%; p = 0.22). The MGuard™ group had lower rates of early major adverse cardiovascular events (MACE) than the DES group (1.9% vs. 13.6%; p = 0.01), due solely to the lower incidence of periprocedural infarction. However, the MACE rate at 1 year was higher in the MGuard™ group (14.3% vs. 4.4%; p = 0.01) at the expense of a higher rate of target lesion revascularization (7.1% vs. 1.3%; p = 0.048). Conclusions: The use of the MGuard™ stent resulted in a reduction of events during hospitalization; however, in the long term the DES were superior in reducing major outcomes, mainly the need for target lesion revascularization
Sujet(s)
Humains , Mâle , Femelle , Sujet âgé , Veine saphène/chirurgie , Endoprothèses , Transplants , Endoprothèses à élution de substances , Héparine/administration et posologie , Acide acétylsalicylique/administration et posologie , Pontage aortocoronarien/méthodes , Coronarographie/méthodes , Études observationnelles comme sujet , Intervention coronarienne percutanée/méthodes , HospitalisationRÉSUMÉ
A revascularização miocárdica anatômica completa está associada a um melhor controle dossintomas anginosos e a menores índices de eventos cardíacos maiores tardios. No entanto, em substancial número de pacientes tratados por meio de intervenção coronária percutânea (ICP), não logramos sua obtenção. Assim, nosso objetivo foi avaliar os fatores associados à revascularização miocárdica incompleta (RMI) em casos de ICP multiarterial. Métodos: Estudo de coorte envolvendo 1.049 pacientes revascularizados de forma prospectiva e consecutivapor meio de ICP com tratamento de dois ou mais vasos, entre 2012 e 2014, divididos em dois grupos: RMI(n = 324; 30,9%) e revascularização miocárdica completa (n = 725; 69,1%).Resultados: A RMI foi significativamente associada a faixa etária maior (66,5 anos vs. 64,1 anos; p = 0,003),hipertensão arterial (92,2% vs. 86,0%; p = 0,006), insuficiência renal crônica (36.4% vs. 26.0%; p < 0,001), síndrome coronariana aguda (26,3% vs. 21,0%; p = 0,05), revascularização cirúrgica prévia (16,1% vs. 7,1%;p = 0,001), lesões em enxertos venosos (3,4% vs. 1,0%; p < 0,001) e oclusões crônicas (3,3% vs. 1,4%; p =0,005), bem como a menor acesso a stents farmacológicos (57,8% vs. 64,8%; p = 0,002). Os resultados clínicos hospitalares não diferiram entre os grupos.Conclusões: A RMI ocorreu em cerca de um terço dos casos tratados, tendo sido observada associação significativa, com um perfil clínico de maior risco e com intervenções em lesões alvo comumente associadas com menor sucesso do procedimento. O grau de revascularização não gerou impacto nosresultados clínicos da fase hospitalar...
Complete anatomical myocardial revascularization is associated with better anginacontrol and lower rates of cardiac events. However, in a significant number of patients treated bypercutaneous coronary intervention (PCI), complete revascularization is not achieved. Thus, the aimof this study was to evaluate factors associated with incomplete myocardial revascularization (IMR) in multivessel PCI patients. Methods: This was a cohort study involving 1,049 prospectively and consecutively revascularized patients through PCI with treatment of two or more vessels, between 2012 and 2014, divided into two groups: IMR(n = 324; 30.9%) and complete myocardial revascularization (n = 725; 69.1%). Results: IMR was significantly associated with older age (66.5 years vs. 64.1 years; p = 0.003), arterial hypertension (92.2% vs. 86.0%; p = 0.006), chronic renal failure (36.4 % vs. 26.0%; p < 0.001), acute coronary syndrome (26.3% vs. 21.0%; p = 0.05), previous surgical revascularization (16.1% vs. 7.1 %; p = 0.001), saphenous venous graft lesions (3.4% vs. 1.0%, p < 0.001), and chronic occlusions (3.3% vs. 1.4%, p = 0.005), as well as lower access to drug-eluting stents (57.8% vs. 64.8%; p = 0.002). In-hospital clinical outcomes did not differ between the groups. Conclusions: IMR occurred in approximately one-third of treated cases, and a significant association was observed with a higher-risk clinical profile and with target lesion interventions commonly associated with lower procedure success. The degree of revascularization had no impact on in-hospital clinical outcomes...
Sujet(s)
Humains , Mâle , Femelle , Sujet âgé , Intervention coronarienne percutanée/méthodes , Patients , Revascularisation myocardique/méthodes , Vaisseaux coronaires/chirurgie , Coronarographie/méthodes , Interprétation statistique de données , Soins de santé tertiaires/méthodes , Maladie des artères coronaires/diagnostic , Maladie des artères coronaires/thérapie , Études de cohortes , Héparine/administration et posologie , Endoprothèses à élution de substancesRÉSUMÉ
Introdução: Estudos recentes têm demonstrado a eficácia do implante transcateter valve-in-valve para otratamento de disfunção de biopróteses em pacientes de alto risco cirúrgico. Apresentamos nossa experiênciainicial com o implante valve-in-valve.Métodos: Caracterizamos o perfil clínico, ecocardiográfico e do procedimento, e reportamos os resultados de médio prazo de pacientes com disfunção de bioprótese submetidos a implante valve-in-valve em posição aórtica. Resultados: Incluímos sete pacientes do sexo masculino, com idade de 72,6 ± 10,0 anos. O escore STS foi 9,6± 10,5%, e o EuroSCORE logístico foi 22,7 ± 14,7%. Três pacientes apresentavam dupla disfunção; dois tinham insuficiência; e dois exibiam estenose isolada. A via transfemoral foi utilizada em seis casos, e a transapical, em um caso. Os dispositivos implantados incluíram as próteses Sapien XT (n = 5) e CoreValve (n = 2). O sucesso do procedimento foi obtido em seis (85,7%) casos. Após o procedimento, o gradiente médio reduziu-se de 38,2 ± 9,6mmHg para 20,9 ± 5,9 mmHg, e a área valvar elevou-se de 1,2 ± 0,4 cm2 para 1,5 ± 0,5 cm2. Ao final de 1 ano, nãoocorreram óbitos e nem outros desfechos adversos significativos; 80% dos pacientes encontravam-se em classefuncional NYHA I/II. Os gradientes transvalvares e a área valvar permaneceram inalterados nesse período. Conclusões: O procedimento valve-in-valve foi eficaz na maioria dos pacientes de alto risco cirúrgico comdisfunção de bioprótese. Quando realizado em pacientes bem selecionados, resulta em desfechos clínicos e hemodinâmicos satisfatórios.
Background: Recent studies have demonstrated the efficacy of the transcatheter valve-in-valveimplantation for the treatment of bioprosthesis dysfunction in high-risk surgical patients. This study presents the initial experience with valve-in-valve implantation. Methods: Clinical, echocardiographic, and procedural profiles were characterized, and the mid-term results of patients with surgical bioprosthesis dysfunction submitted to valve-in-valve implantation in theaortic position were reported.Results: Seven male patients were included, aged 72.6 ± 10.0 years. The STS score was 9,6 ± 10,5%, andthe logistic EuroSCORE was 22.7 ± 14.7%. Three patients had combined aortic bioprosthesis failure; two had isolated regurgitation; and two had isolated stenosis. The transfemoral access was used in six cases, and the transapical access in one case. Implanted devices included Sapien XT (n = 5) and CoreValve (n = 2) prostheses. Procedural success was achieved in six (85.7%) cases. After the procedure, the mean gradient decreased from 38.2 ± 9.6 mmHg to 20.9 ± 5.9 mmHg, and the valve area increased from 1.2 ±0.4 cm2 to 1.5 ± 0.5 cm2. After 1 year, there were no deaths and no other significant adverse outcomes; 80% of patients were in NYHA functional class I/II. The transvalvular gradients and valve area remained unchanged in this period.
Sujet(s)
Humains , Mâle , Sujet âgé , Bioprothèse , Sténose aortique/diagnostic , Sténose aortique/thérapie , Remplacement valvulaire aortique par cathéter/méthodes , Interprétation statistique de données , Échocardiographie/méthodes , Facteurs de risque , Prothèses et implants/méthodes , Appréciation des risques/méthodes , Traitement médicamenteux/méthodes , Valve aortique/chirurgie , Ventricules cardiaquesRÉSUMÉ
Stents farmacológicos (SF) de segunda geração demonstraram melhor desempenho clínico que os de primeira geração, sobretudo pela redução nas taxas de trombose, mas ainda não está claro se esse benefício se estende a diabéticos da prática diária. Objetivamos comparar o desempenho de pacientes diabéticos não selecionados tratados com SF eluidores de sirolimus (SES; primeira geração) vs. SF eluidoresde everolimus (SEE; segunda geração).Métodos: Entre 2007 e 2014, 798 diabéticos foram tratados com SES (n = 414) ou SEE (n = 384) e incluídosnesta análise. Seguimento clínico tardio foi obtido em 99,4% da população e os grupos foram comparados quanto à ocorrência de eventos cardíacos adversos maiores (ECAM) e trombose de stent. Resultados: A idade da população foi semelhante, com predomínio do sexo masculino. Em ambas as coortes, a apresentação clínica mais frequente foi a doença coronária estável. Número de vasos tratados (1,50 ± 0,62 vs. 1,52 ± 0,72; p = 0,88) e extensão total de stents (36,1 ± 20,4 mm vs. 37,7 ± 22,2 mm; p = 0,32) foram semelhantes. Os pacientes tratados com SEE apresentaram menores taxas de ECAM (15% vs. 6,8%; p < 0,001), sobretudo à custa de menor mortalidade cardíaca (5,3% vs. 1,3%; p < 0,001). Observou-se também menor ocorrência de trombose de stent definitiva/provável com SF de segunda geração (3,4% vs. 0,5%; p = 0,004).Conclusões: Nesta experiência unicêntrica, o uso de SEE em diabéticos mostrou-se com menor mortalidadecardíaca e trombose da endoprótese. Esse benefício se fez mais evidente no seguimento mais tardio...
Despite the better clinical performance of second-generation drug-eluting stents (DES)when compared to first-generation DES in controlled trials, mainly due to reduction in thrombosis rate, it remains unclear whether this benefit extends to diabetic patients treated in the daily practice. We sought to compare the clinical outcomes of unselected diabetic patients treated with either sirolimus eluting stents - SES (first-generation DES) or everolimus-eluting stents - EES (second-generation DES). Methods: Between January 2007 and October 2014 a total of 798 diabetic patients were treated with SES(n = 414) and EES (n = 384). Long-term clinical follow-up was achieved in 99,4% of the population andthe groups were compared regarding the occurrence of major adverse cardiac events (MACE) and stent thrombosis. Results: In both cohorts age was similar, and most patients were male. Stable coronary disease was the most frequent clinical presentation. The number of treated vessels (1.50 ± 0.62 vs. 1.52 ± 0.72; p = 0.88)and the total stent length (36.1 ± 20.4 vs. 37.7 ± 22.2 mm; p = 0.32) were similar between groups. Patients treated with EES showed lower rates of MACE (15% vs. 6.8%, p < 0.001), mainly due to a lower cardiac death(5.3% vs. 1.3%, p < 0.001). There was also less definitive/ probable thrombosis with the second generation DES (3.4% vs. 0.5%, p = 0.004)...
Sujet(s)
Humains , Mâle , Femelle , Adulte d'âge moyen , Diabète/diagnostic , Diabète/thérapie , Sirolimus/administration et posologie , Endoprothèses à élution de substances , Thrombose coronarienne/physiopathologie , Études prospectives , Facteurs de risque , Fibrinolytiques/administration et posologie , Prothèses et implants/méthodes , Intervention coronarienne percutanée/méthodes , Résultat thérapeutiqueRÉSUMÉ
Introdução: O implante por cateter de prótese aórtica (TAVI, do inglês transcatheter aortic valve implantation) constitui tratamento alternativo para pacientes com estenose aórtica de alto risco cirúrgico ou inoperáveis. Para adquirir competência, o grupo multidisciplinar deve receber treinamento específico e acumular experiência na execução do TAVI. Contudo, sua curva de aprendizado não está bem estabelecida. Nosso objetivo foi analisar o impacto da curva de aprendizado na seleção de pacientes, nos aspectos técnicos e nos resultados clínicos do TAVI. Métodos: Estudo observacional e prospectivo dos primeiros 150 pacientes submetidos a TAVI por via femoral, entre janeiro de 2009 e dezembro de 2013 divididos em tercis (n = 50) de acordo com a data do procedimento. Os desfechos foram definidos conforme os critérios Valve Academic Research Consortium-2 (VARC-2). Resultados: A idade foi de 82,5 ± 6,7 anos, sendo 44% homens e 75% em classe NYHA III/IV. O EuroSCORE (24,2 ± 13% vs. 21,2 ± 10,8% vs. 23,4 ± 14,3%) e o STS Score (5,9 ± 2,9% vs. 6,7 ± 4,3% vs. 5,8 ± 3,1%) foram similares entre os grupos. Observou-se redução gradativa nos tempos do procedimento (107,2 ± 48,1 minutos vs. 90,3 ± 42,2 minutos vs. 76,6 ± 37,7 minutos; p < 0,01) e de fluoroscopia (31,3 ± 9,6 minutos vs. 25,4 ± 8,7 minutos vs. 17,2 ± 6,2 minutos; p = 0,01), e no ...
Background: Transcatheter aortic valve implantation (TAVI) is an alternative treatment for high-risk or inoperable patients with aortic stenosis. The multidisciplinary team must undergo specific training and accumulate experience to achieve optimal results. However, its learning curve is not well established. Our objective was to investigate the impact of learning curve on patient selection, technical aspects and clinical outcomes of TAVI. Methods: Observational, prospective analysis of the first 150 patients undergoing transfemoral TAVI between January 2009 and December 2013. Patients were divided into tertiles (n = 50), according to the procedure date. Outcomes were defined according to Valve Academic Research Consortium-2 (VARC-2) criteria. Results: Mean age was 82.5 ± 6.7 years, 44% were male and 75% were in NYHA class III/IV. EuroS-CORE (24.2 ± 13% vs. 21.2 ± 10.8% vs. 23.4 ± 14.3%) and STS Score (5.9 ± 2.9% vs. 6.7 ± 4.3% vs. 5.8 ± 3.1%) were similar between groups. A gradual decrease was observed in procedure times (107.2 ± 48.1 minutes vs. 90.3 ± 42.2 minutes vs. 76.6 ± 37.7 minutes; p < 0.01), fluoroscopy times (31.3 ± 9,6 minutes vs. 25.4 ± 8.7 minutes vs. 17.2 ± 6.2 minutes; p = 0.01) and contrast volume (145.5 ± 70.9 mL vs. 123.2 ± 87.8 mL vs. 101.1 ± 50 mL; p = 0.01). Mortality decreased gradually (20% vs. 10% vs. 4%; p = 0,047), and lower bleeding and moderate-to-severe aortic regurgitation were ...
RÉSUMÉ
Fundamento: A hipertensão arterial sistêmica constitui importante problema de saúde pública e significativa causa de mortalidade cardiovascular. A elevada prevalência e as reduzidas taxas de controle tensional despertaram o interesse por estratégias terapêuticas alternativas. A denervação simpática renal percutânea surgiu como perspectiva no tratamento de hipertensos resistentes. Objetivo: Avaliar a factibilidade e a segurança da denervação renal com cateter irrigado. Métodos: Dez hipertensos resistentes foram submetidos ao procedimento. O desfecho primário foi a segurança, avaliada por eventos adversos periprocedimento, função renal e anormalidade vascular renal aos 6 meses. Os desfechos secundários constituíram mudanças na pressão arterial (consultório e monitorização ambulatorial) e no número de anti-hipertensivos aos 6 meses. Resultados: A média de idade foi de 47,3 (± 12) anos, 90% eram mulheres. No primeiro caso, houve dissecção de artéria renal causada por trauma da bainha, fato que não se repetiu após ajuste técnico, demonstrando efeito da curva de aprendizado. Nenhum caso de trombose/infarto renal ou óbito foi reportado. Não se observou elevação dos níveis séricos de creatinina durante o seguimento. Aos 6 meses, diagnosticou-se um caso de estenose significativa de artéria renal, sem repercussão clínica. A denervação renal reduziu a pressão arterial de consultório, em média, em 14,6/6,6 mmHg (p = 0,4 tanto para pressão arterial sistólica como para a diastólica). A redução média da pressão arterial pela monitorização ambulatorial foi de 28/17,6 mmHg (p = 0,02 e p = 0,07 para pressão arterial sistólica e diastólica, ...
Background: Systemic hypertension is an important public health problem and a significant cause of cardiovascular mortality. Its high prevalence and the low rates of blood pressure control have resulted in the search for alternative therapeutic strategies. Percutaneous renal sympathetic denervation emerged as a perspective in the treatment of patients with resistant hypertension. Objective: To evaluate the feasibility and safety of renal denervation using an irrigated catheter. Methods: Ten patients with resistant hypertension underwent the procedure. The primary endpoint was safety, as assessed by periprocedural adverse events, renal function and renal vascular abnormalities at 6 months. The secondary endpoints were changes in blood pressure levels (office and ambulatory monitoring) and in the number of antihypertensive drugs at 6 months. Results: The mean age was 47.3 (± 12) years, and 90% of patients were women. In the first case, renal artery dissection occurred as a result of trauma due to the long sheath; no further cases were observed after technical adjustments, thus showing an effect of the learning curve. No cases of thrombosis/renal infarction or death were reported. Elevation of serum creatinine levels was not observed during follow-up. At 6 months, one case of significant renal artery stenosis with no clinical consequences was diagnosed. Renal denervation reduced office blood pressure levels by 14.6/6.6 mmHg, on average (p = 0.4 both for systolic and diastolic blood pressure). Blood pressure levels on ambulatory monitoring decreased by 28/17.6 mmHg (p = 0.02 and p = 0.07 for systolic and diastolic blood pressure, respectively). A mean reduction of 2.1 antihypertensive drugs was observed. Conclusion: Renal denervation is feasible and safe in the treatment of resistant systemic arterial hypertension. Larger studies are required to confirm our findings. .
Sujet(s)
Humains , Mâle , Femelle , Adulte , Adulte d'âge moyen , Ablation par cathéter/méthodes , Hypertension artérielle/chirurgie , Rein/innervation , Sympathectomie/méthodes , Angiographie , Surveillance ambulatoire de la pression artérielle , Pression sanguine/physiologie , Créatinine/sang , Études de faisabilité , Artère rénale/innervation , Reproductibilité des résultats , Facteurs temps , Résultat thérapeutiqueRÉSUMÉ
Fundamento: O implante de prótese aórtica transcateter é uma alternativa efetiva para o tratamento cirúrgico para a correção de estenose aórtica grave em pacientes inoperáveis ou de alto risco cirúrgico. Objetivos: Apresentar os resultados clínicos e ecocardiográficos imediatos e no médio prazo da experiência inicial do implante de prótese aórtica transcateter. Métodos: Entre junho de 2009 e fevereiro de 2013, 112 pacientes foram submetidos a implante de prótese aórtica transcateter. Resultados: A idade média foi 82,5 ± 6,5 anos e o Euro SCORE logístico foi 23,6 ± 13,5. O sucesso do procedimento foi de 84%. Após o implante, houve queda do gradiente sistólico médio (pré = 54,7 ± 15,3 mmHg vs. pós = 11,7 ± 4,0 mmHg; p < 0,01). Acidente vascular cerebral ocorreu em 3,6% dos pacientes, complicações vasculares em 19%, e foi necessário o implante de marca-passo definitivo em 13% dos pacientes nos primeiros 30 dias pós-implante. A mortalidade aos 30 dias e no seguimento médio de 16 ± 11 meses foi, respectivamente, de 14 e de 8,9%. A presença de doença pulmonar obstrutiva crônica foi o único preditor de mortalidade em 30 dias e no seguimento. A área valvar aórtica e o gradiente sistólico médio não apresentaram variações significativas durante o seguimento. Conclusões: O implante de prótese aórtica transcateter é um procedimento eficaz e seguro para o tratamento da estenose aórtica em pacientes de alto risco cirúrgico ou inoperáveis. A presença de doença pulmonar obstrutiva crônica foi o único preditor independente de mortalidade identificado, tanto no primeiro mês pós-intervenção quanto no seguimento mais tardio. .
Background: Transcatheter aortic valve implantation is an effective alternative to surgical treatment of severe aortic stenosis in patients who are inoperable or at high surgical risk. Objectives: To report the immediate and follow-up clinical and echocardiographic results of the initial experience of transcatheter aortic valve implantation. Methods: From 2009 June to 2013 February, 112 patients underwent transcatheter aortic valve implantation. Results: Mean age was 82.5 ± 6.5 years, and the logistic EuroSCORE was 23.6 ± 13.5. Procedural success was 84%. After the intervention, a reduction in the mean systolic gradient was observed (pre: 54.7 ± 15.3 vs. post: 11.7 ± 4.0 mmHg; p < 0.01). Cerebrovascular accidents occurred in 3.6%, vascular complications in 19% and permanent pacemaker was required by 13% of the patients. Thirty-day mortality and at follow-up of 16 ± 11 months was 14% and 8.9% respectively. The presence of chronic obstructive pulmonary disease was the only predictor of mortality at 30 days and at follow-up. During follow up, aortic valve area and mean systolic gradient did not change significantly. Conclusions: Transcatheter aortic valve implantation is an effective and safe procedure for the treatment of aortic stenosis in high-surgical risk or inoperable patients. The presence of chronic obstructive pulmonary disease was the only independent predictor of mortality identified both in the first month post-intervention and at follow-up. .
Sujet(s)
Humains , Mâle , Femelle , Sujet âgé , Sujet âgé de 80 ans ou plus , Sténose aortique/chirurgie , Cathétérisme cardiaque/méthodes , Prothèse valvulaire cardiaque , Implantation de valve prothétique cardiaque/méthodes , Sténose aortique/mortalité , Sténose aortique , Cathétérisme cardiaque/effets indésirables , Cathétérisme cardiaque/mortalité , Échocardiographie-doppler , Études de suivi , Implantation de valve prothétique cardiaque/effets indésirables , Implantation de valve prothétique cardiaque/mortalité , Hémodynamique , Estimation de Kaplan-Meier , Complications postopératoires , Appréciation des risques , Facteurs de risque , Statistique non paramétrique , Accident vasculaire cérébral/étiologie , Facteurs temps , Résultat thérapeutiqueRÉSUMÉ
Introdução: Resultados de 3 anos do Symplicity HTN-1 mostraram superioridade da denervação simpática renal percutânea comparada à terapia medicamentosa em hipertensos resistentes. Entretanto, os desfechos de eficácia da denervação simpática renal percutânea no Symplicity HTN-3, primeiro ensaio controlado com procedimento simulado, não foram alcançados. Nosso objetivo foi relatar os resultados de segurança e de eficácia da denervação simpática renal percutânea utilizando o cateter de ablação por radiofrequência de ponta irrigada em hipertensos resistentes. Métodos: Vinte e um pacientes foram submetidos ao procedimento desde julho 2012, dentre eles nove com seguimento ≥ 12 meses, os quais foram incluídos nesta análise. O desfecho primário foi a segurança, avaliada por eventos adversos peri-procedimento, função renal e anormalidade vascular renal aos 6 meses. Os desfechos secundários incluíram mudanças na pressão arterial obtida no consultório e no número de anti-hipertensivos aos 12 meses. Resultados: A média de idades foi 48,8 ± 11,7 anos. No primeiro caso, houve dissecção de artéria renal causada por trauma da bainha. Nenhum caso de trombose, infarto renal ou óbito foi observado. Não se constatou elevação dos níveis séricos de creatinina durante o seguimento. Aos 6 meses, diagnosticou-se um caso de estenose significativa de artéria renal, sem repercussão clínica. A redução média da pressão arterial no consultório foi de 41,1 ± 33,2/18,6 ± 15,2 mmHg (p = 0,04 para pressão arterial sistólica e p = 0,08 para pressão arterial diastólica) e houve redução de 2,0 ± 2,3 no número de anti-hipertensivos aos 12 meses (p = 0,03). Conclusões: A denervação simpática renal percutânea, utilizando o cateter de ablação por radiofrequência de ponta irrigada, mostrou ser factível, segura e eficaz.
Background: The 3-year results of the Symplicity HTN-1 trial have shown the superiority of renal sympathetic denervation over drug treatment in patients with resistant hypertension. However, the efficacy of renal sympathetic denervation was not confirmed by Symplicity HTN-3, the first sham-controlled study. Our objective was to report the safety and efficacy of renal sympathetic denervation using the irrigated radiofrequency ablation catheter in patients with resistant hypertension. Methods: Twenty-one patients were submitted to the procedure since July 2012, nine of them had a follow-up ≥ 12 months and were included in this analysis. The primary endpoint was safety, evaluated by periprocedural adverse events, renal function and renal vascular abnormalities at 6 months. Secondary endpoints included changes in blood pressure obtained in office and in the number of anti-hypertensive drugs at 12 months. Results: Mean age was 48.8 ± 11.7 years. In the first case, there was a renal artery dissection caused by the vascular sheath. There were no cases of thrombosis, renal infarction or death. Serum creatinine levels did not increase during the follow-up period. At 6 months, one case of significant renal stenosis without clinical impact was diagnosed. The average reduction in office blood pressure was 41.1 ± 33.2/18.6 ± 15.2 mmHg (p = 0.04 for systolic blood pressure and p = 0.08 for diastolic blood pressure) and there was a mean reduction of 2.0 ± 2.3 in the number of anti-hypertensive drugs at 12 months (p = 0.03). Conclusions: Renal sympathetic denervation using the irrigated radiofrequency ablation catheter proved to be feasible, safe and effective.
Sujet(s)
Humains , Mâle , Femelle , Adulte d'âge moyen , Ablation par cathéter/méthodes , Hypertension artérielle/physiopathologie , Hypertension artérielle/thérapie , Résistance aux substances , Angiographie/méthodes , Antihypertenseurs/administration et posologie , Antihypertenseurs/usage thérapeutique , Résultat thérapeutique , Sympathectomie/effets indésirablesRÉSUMÉ
INTRODUÇÃO: A conformabilidade do stent, definida como a adaptação da prótese à forma natural do vaso, é a principal responsável pelas alterações geométricas produzidas após o implante do dispositivo, sendo influenciada pelo material e pelo desenho do stent. Ela pode ser aferida medindo-se as modificações da curvatura e a angulação do segmento tratado após o implante do stent. O objetivo deste estudo foi comparar as mudanças na angulação coronária após implante do suporte vascular bioabsorvível (SVB) e das plataformas metálicas de cromo-cobalto e aço inoxidável, utilizadas em stents farmacológicos de segunda geração. MÉTODOS: Foram incluídos, nesta análise retrospectiva, 50 pacientes com lesões únicas, de novo, em coronárias nativas, com diâmetro entre 2,5 e 3,5 mm e extensão de até 23 mm. Vinte e cinco pacientes foram tratados com SVB e 25 pacientes com plataformas metálicas de cromo-cobalto (n = 12) ou de aço inoxidável (n = 13). A angulação foi medida usando um software de angiografia coronária quantitativa dedicado. RESULTADOS: A angulação do vaso modificou-se significativamente após o implante dos dispositivos. No grupo submetido ao implante de plataformas metálicas, houve maior modificação do ângulo coronário quando comparado ao tratado com SVB (41,6% vs. 14,9%; P < 0,01). Quando observado o comportamento do SVB e das diferentes plataformas metálicas, a alteração do ângulo coronário foi maior para as plataformas de aço inoxidável, seguida das plataformas de cromo-cobalto e os SVB (53,7% vs. 28,5% vs. 14,9%; P < 0,01). CONCLUSÕES: Nesta avaliação preliminar, o SVB produziu uma menor mudança da angulação coronária. O impacto clínico deste achado necessita ser investigado prospectivamente em uma coorte maior e mais complexa.
BACKGROUND: The conformability of the stent, defined as the adaptation of the prosthesis to the natural shape of the vessel, is the major cause of geometrical changes after stenting and is influenced by the stent material and design. It may be assessed by measuring changes in the curvature and the angulation of the treated segment after stent implantation. The objective of this study was to compare changes in coronary angulation after implantation of the bioresorbable vascular scaffold (BVS) and cobalt-chromium and stainless steel metal platforms used in second-generation drug-eluting stents. METHODS: In this retrospective analysis, 50 patients with single de novo lesions in native coronary arteries and diameter between 2.5 and 3.5 mm and length up to 23 mm were included. Twenty-five patients were treated with BVS and 25 patients were treated with cobalt-chromium (n = 12) or stainless steel (n = 13) platforms. Angulation was measured using a dedicated quantitative angiography analysis software. RESULTS: Vessel angulation significantly changed after device implantation. In the group submitted to the implantation of metal platforms there was greater coronary angulation change when compared to the group treated with BVS (41.6% vs. 14.9%; P < 0.01). When we analyzed the performance of the BVS and the different metal platforms, coronary angulation change was greater for the stainless steel platforms, followed by cobalt-chromium platforms and the BVS (53.7% vs. 28.5% vs. 14.9%; P < 0.01). CONCLUSIONS: In this preliminary assessment, the BVS produced a smaller coronary angulation change. The clinical impact of this finding must be prospectively investigated in a larger and more complex cohort.
Sujet(s)
Humains , Mâle , Femelle , Adulte d'âge moyen , Implant résorbable , Vaisseaux coronaires , Endoprothèses à élution de substances , Coronarographie/méthodes , Études rétrospectives , EndoprothèsesRÉSUMÉ
INTRODUÇÃO: O benefício do implante direto de stent não está bem estabelecido na síndrome coronária aguda sem supradesnivelamento do segmento ST (SCASST). Comparamos aqui o implante de stent, com ou sem pré-dilatação (stent direto) da lesão-alvo nessa população. MÉTODOS: Registro unicêntrico, retrospectivo, que incluiu pacientes com SCASST tratados entre 2009 a 2010. Foram excluídas lesões reestenóticas, lesões em enxertos de safena ou em bifurcações. O desfecho primário foi a comparação de eventos cardíacos adversos maiores (ECAM) hospitalares e tardios. RESULTADOS: Do total de 182 pacientes avaliados, 42,3% foram tratados com stent direto. A idade da população foi de 61,1 ± 11,0 anos, sendo 67% do sexo masculino e 33,5% diabéticos. Os pacientes do grupo pré-dilatação apresentaram mais lesões do tipo C (37,1% vs. 18,2%; P <0,01), menor diâmetro de referência do vaso (2,3 [2,0-2,7] mm vs. 2,7 [2,2-3,1] mm; P <0,01) e menor diâmetro luminal mínimo pré-intervenção (0,5 [0,1-0,7] mm vs. 0,6 [0,4-1,0] mm; P < 0,01). Calcificação moderada/grave foi evidenciada em 13,2% dos casos, igualmente distribuídos entre os grupos. Não foram observadas diferenças na ocorrência de complicações angiográficas periprocedimento (3,9% vs. 4,8%; P > 0,99). As taxas de ECAM hospitalar não diferiram entre os grupos, embora os pacientes submetidos ao implante direto tenham apresentado metade dos eventos (2,6% vs. 5,7%; P = 0,47). Ao final de 1 ano, os ECAM foram semelhantes entre os grupos (6,5% vs. 5,7%; P > 0,99 ). CONCLUSÕES: Nesta série de pacientes com SCASST, o implante direto de stent não esteve associado a melhores resultados angiográficos ou clínicos. Contudo, a complexidade da lesão permanece como fator determinante na escolha da estratégia de pré-dilatação na prática diária.
BACKGROUND: The benefits of direct stenting in non-ST-segment-elevation acute coronary syndromes (NSTE ACS) are not clearly established. We compared stenting with or without pre-dilatation (direct stenting) of the target lesion in this population. METHODS: Single center, retrospective registry including NSTE ACS patients treated from 2009 to 2010. Stenting for bifurcations, saphenous vein grafts, and in-stent restenosis were excluded. The primary endpoint was the comparison of in-hospital and late major adverse cardiac events (MACE). RESULTS: Of a total of 182 patients, 42.3% were treated by direct stenting. Mean age was 61.1 ± 11.0 years, 67% were male and 33.5% were diabetics. Patients in the pre-dilatation group had more type C lesions (37.1% vs. 18.2%; P = 0.01), smaller reference vessel diameter (2.3 [2.0-2.7] mm vs. 2.7 [2.2-3.1] mm; P = 0.01) and smaller preintervention minimal luminal diameter (0.5 [0.1-0.7] mm vs. 0.6 [0.4-1.0] mm; P < 0.01). Moderate/severe calcification was observed in 13.2% of the cases, and was equally distributed in both groups. There were no differences in the occurrence of periprocedural angiographic complications (3.9% vs. 4.8%; P = 0.99). In-hospital MACE was not different between groups, although patients submitted to direct stenting have shown half of the events (2.6% vs. 5.7%; P = 0.47). At the end of 1 year, the MACE rate was similar for the two groups (6.5% vs. 5.7%; P > 0.99). CONCLUSIONS: In this series of NSTE ACS patients, direct stenting was not associated with better angiographic or clinical outcomes. However, lesion complexity remains a determinant factor in the choice of the pre-dilatation strategy in daily practice.
Sujet(s)
Humains , Mâle , Femelle , Adulte d'âge moyen , Intervention coronarienne percutanée/méthodes , Endoprothèses , Syndrome coronarien aigu/physiopathologie , Coronarographie/méthodes , Études rétrospectivesRÉSUMÉ
INTRODUÇÃO: Suportes vasculares bioabsorvíveis (SVB) têm sido desenvolvidos como forma de fornecer sustentação à parede do vaso enquanto ocorre o processo de cicatrização, após a intervenção coronária percutânea (ICP), sendo absorvido posteriormente. Pelo fato da plataforma ser de material polimérico, existe preocupação em relação à retração aguda do dispositivo. Avaliamos aqui a retração aguda do SVB com a de dois diferentes stents farmacológicos metálicos. MÉTODOS: Foram incluídos 50 pacientes com lesões não complexas. Dentre esses pacientes, 25 foram tratados com SVB e comparados a outros 25 pacientes tratados com stent de cromo-cobalto eluidor de everolimus (EES; n = 12) ou stent de aço inoxidável eluidor de biolimus (BES; n = 13). A retração aguda foi definida como a diferença entre o diâmetro médio do balão durante a pressão máxima de inflação (X) e o diâmetro médio do stent após o esvaziamento do balão (Y). A porcentagem de retração aguda foi definida como (X - Y)/X. RESULTADOS: Não houve diferença significativa em relação às características clínicas e angiográficas basais. O ganho luminal agudo foi menor com o SVB comparado ao EES e ao BES (1,51 ± 0,41 mm vs. 1,76 ± 0,28 mm vs. 1,9 ± 0,42 mm; P = 0,02). A retração aguda foi de 0,21 ± 0,13 mm vs. 0,15 ± 0,08 mm vs. 0,14 ± 0,08 mm (P = 0,21), e o porcentual de retração aguda foi de 7,0 ± 4,6% vs. 5,0 ± 2,2% vs. 5,7 ± 4,1% (P = 0,16). CONCLUSÕES: O SVB demonstrou ter retração aguda ligeiramente maior, embora não significativa, que os stents metálicos farmacológicos de segunda geração.
BACKGROUND: Bioresorbable vascular scaffolds (BVS) have been developed to provide support to the vessel wall during the healing process after percutaneous coronary intervention (PCI), being reabsorbed afterwards. Because the scaffold is made of polymeric material, there is a concern regarding the acute recoil of the device. We compared the BVS acute recoil with that of two different metallic drug-eluting stents. METHODS: Fifty patients with non-complex lesions were included. Twenty-five of these patients were treated with a BVS who were compared to 25 patients treated with a cobalt-chromium everolimus-eluting stent (EES, n = 12) or a stainless steel biolimus-eluting stent (BES, n = 13). Acute recoil was defined as the difference between the mean diameter of the balloon during maximum inflation pressure (X) and the mean diameter of the stent immediately after balloon deflation (Y). The percentage of acute recoil was defined as (X-Y)/X. RESULTS: There was no significant difference in the baseline clinical and angiographic characteristics. Acute luminal gain was lower with BVS compared to EES and BES (1.51 ± 0.41 mm vs. 1.76 ± 0.28 mm vs. 1.9 ± 0.42 mm, P = 0.02). Acute recoil was 0.21 ± 0.13 mm vs. 0.15 ± 0.08 mm vs. 0.14 ± 0.08 mm (P = 0.21) and the percentage of acute recoil was 7.0 ± 4.6% vs. 5.0 ± 2.2% vs. 5.7 ± 4.1% (P = 0.16). CONCLUSIONS: BVS presented a slightly higher, although not significant, acute recoil than the two second-generation metallic drug-eluting stents.
Sujet(s)
Humains , Mâle , Femelle , Adulte d'âge moyen , Implant résorbable , Intervention coronarienne percutanée/méthodes , Endoprothèses à élution de substances , Coronarographie/méthodes , Analyse de variance , Études rétrospectivesRÉSUMÉ
FUNDAMENTO: Na angioplastia coronária percutânea (ACP), os vasos de fino calibre representam um fator de risco para reestenose. O stent farmacológico (SF) autoexpansível Sparrow®, de perfil menor que os sistemas atuais, nunca foi testado nesse cenário. OBJETIVOS: Avaliar a eficácia tardia do SF Sparrow®, com relação à perda luminal tardia intrastent (PLT intrastent) aos oito meses. MÉTODOS: Estudo prospectivo, randomizado, em P com doença arterial coronária (DAC) sintomática ou com isquemia documentada, submetido à ACP em vasos de calibre < 2,75 mm, dividido em dois grupos quanto ao tipo de stent Sparrow®: grupo 1, SF; grupo 2, stent não farmacológico (SNF). O seguimento clínico foi de 12 meses. De imediato e aos oito meses, avaliação pela angiografia coronária quantitativa (ACQ). Para o cálculo da amostra estimou-se diminuição de mais de 65% de PLT intrastent com o SF. Para análise estatística utilizou-se o programa IBM SPSS Statistics® versão 19 (Chicago, Illinois, EUA). RESULTADOS: Foram incluídos 24 p, 12 em cada grupo. Os grupos SF e SNF foram semelhantes quanto à idade (63,25 ± 10,01 versus 64,58 ± 11,54, p = 0,765), sexo masculino (58,3% versus 33,3%, p = 0,412), fatores de risco e todos os aspectos angiográficos. Os resultados imediatos foram satisfatórios em ambos os grupos. Aos oito meses, a PLT intrastent foi significativamente menor no SF do que no SNF (SF 0,25 ± 0,16 versus SNF 0,97 ± 0,76, p = 0,008). CONCLUSÃO: Em ACP de vasos de calibre < 2,75 mm, o SF Sparrow® determinou significativa redução da PLT intrastent, em comparação ao SNF Sparrow®.
BACKGROUND: Small vessels represent a risk factor for restenosis in percutaneous coronary angioplasty (PCA). The Sparrow® self-expanding drug-eluting stent, which has a lower profile than the current systems, has never been tested in this scenario. OBJECTIVES: To evaluate the late effectiveness of the Sparrow® drug-eluting stent, regarding in-stent late lumen loss (LLL). METHODS: Patients with ischemia, symptomatic or documented, were submitted to PCA in vessels with reference diameter < 2.75 mm, divided into two groups regarding Sparrow® stent type: group 1: Sparrow® drug-eluting stent (DES), group 2: Sparrow® bare metal stent (BMS). Clinical follow-up duration was 12 months. Evaluation using quantitative coronary angiography (QCA) was performed immediately and at 8 months. A decrease of over 65% of in-stent LLL with DES was estimated to calculate sample size. IBM® SPSS software, release 19 (Chicago, Illinois, USA) was used for the statistical analysis. RESULTS: A total of 24 patients were randomized, 12 in each group. The DES and BMS groups were similar in age (63.25 ± 10.01 vs. 64.58 ± 11.54, p = 0.765), male gender (58.3% vs. 33.3%, p = 0.412), risk factors and all angiographs aspects. Immediate results were satisfactory in both groups. At 8 months in-stent late lumen loss was significantly lower in DES than in BMS group (DES vs. BMS 0.25 ± 0.16 0.97 ± 0.76, p = 0.008). CONCLUSION: In small-vessel PCA, the Sparrow® DES determined significant reduction in in-stent LLL, when compared to Sparrow® BMS.
Sujet(s)
Sujet âgé , Femelle , Humains , Mâle , Adulte d'âge moyen , Resténose coronaire/prévention et contrôle , Vaisseaux coronaires/physiopathologie , Endoprothèses à élution de substances , Miniaturisation , Angioplastie coronaire par ballonnet , Sténose coronarienne , Endoprothèses , Sirolimus/administration et posologie , Résultat thérapeutiqueRÉSUMÉ
FUNDAMENTOS: Estudos prévios demonstram que o principal determinante de vulnerabilidade da placa aterosclerótica é a sua composição. Recentemente, diversos métodos de imagens e marcadores laboratoriais têm sido investigados visando identificar lesões vulneráveis. O ultrassom com Histologia Virtual® (HV) permite a diferenciação e quantificação dos componentes da placa. Por sua vez, a proteína C-reativa (PCR) é apontada como importante preditor de eventos adversos. A correlação entre este marcador e as características da placa não é bem estabelecida. OBJETIVOS: Avaliar a constituição da lesão culpada em pacientes com síndrome coronária aguda (SCA) - conforme caracterizada pela HV - e investigar a relação dos componentes da placa com o marcador inflamatório PCR. MÉTODOS: Cinquenta e dois pacientes com SCA e com indicação de intervenção coronária percutânea foram submetidos a dosagens de PCR de alta sensibilidade antes e 24 horas após a ICP. Análise por ultrassom HV da lesão-alvo foi realizada antes da ICP. RESULTADOS: A média de idade foi de 55,3 ± 4,9 anos, sendo 76,9% homens, 67,3% hipertensos e 30,8% diabéticos. A área luminal mínima foi de 3,9 ± 1,3 mm², e a carga de placa de 69 ± 11,3%. Os componentes da placa foram assim identificados: fibrótico (59,6 ± 15,8%), fibrolipídico (7,6 ± 8,2%), cálcio (12,1 ± 9,2%), necrótico (20,7 ± 12,7%). Não observamos correlação entre os níveis basais de PCR ou a variação dentre os valores pré e pós-ICP com os componentes da placa. CONCLUSÃO: Neste estudo, a composição das placas pela HV foi predominantemente fibrótica, com alto conteúdo necrótico. Não foi encontrada correlação entre a PCR e os componentes da lesão culpada em pacientes com SCA.
BACKGROUND: Previous studies have shown that coronary plaque composition plays a pivotal role in plaque instability, and imaging modalities and serum biomarkers have been investigated to identify vulnerable plaque. Virtual histology IVUS (VH-IVUS) characterizes plaque components as calcified, fibrotic, fibrofatty, or necrotic core. C-reactive protein (hsCRP) is an independent risk factor and a powerful predictor of future coronary events. However, a relationship between inflammatory response indicated by CRP and plaque characteristics in ACS patients remains not well established. OBJECTIVE: To determine, by using VH-IVUS, the relation between coronary plaque components and plasma high-sensitivity CRP levels in patients with acute coronary syndromes (ACS). METHODS: 52 patients with ACS were enrolled in this prospective study. Electrocardiographically-gated VH-IVUS were performed in the culprit lesion before PCI. Blood sample was drawn from all patients before the procedure and after 24 hours, and hs-CRP levels were determined. RESULTS: Mean age was 55.3±4.9 years, 76.9% were men and 30.9% had diabetes. Mean MLA was 3.9±1.3 mm², and plaque burden was 69±11.3%, as assessed by IVUS. VH-IVUS analysis at the minimum luminal site identified plaque components: fibrotic (59.6±15.8%), fibrofatty (7.6±8.2%), dense calcium (12.1±9.2%) and necrotic core (20.7±12.7%). Plasma hs-CRP (mean 16.02±18.07 mg/L) did not correlate with necrotic core (r=-0.089, p = 0.53) and other plaque components. CONCLUSIONS: In this prospective study with patients with ACS, the predominant components of the culprit plaque were fibrotic and necrotic core. Serum hs C-reactive protein levels did not correlate with plaque composition.
Sujet(s)
Adulte , Sujet âgé , Femelle , Humains , Mâle , Adulte d'âge moyen , Syndrome coronarien aigu/anatomopathologie , Syndrome coronarien aigu , Protéine C-réactive/analyse , Plaque d'athérosclérose/composition chimique , Plaque d'athérosclérose , Syndrome coronarien aigu/sang , Marqueurs biologiques/sang , Calcium/analyse , Coronarographie , Fibrose/anatomopathologie , Nécrose/anatomopathologie , Plaque d'athérosclérose/sang , Valeurs de référence , Reproductibilité des résultats , Échographie/méthodesRÉSUMÉ
INTRODUÇÃO: A incidência de refluxo paraprotético (RPP) parece maior entre os pacientes submetidos a implante de prótese aórtica transcateter e sua potencial associação com aumento da mortalidade tardia tem suscitado preocupação na comunidade científica. Nosso objetivo foi avaliar a incidência e o impacto clínico e estabelecer preditores do RPP em nossa casuística. MÉTODOS: Entre julho de 2009 e fevereiro de 2013, 112 pacientes foram submetidos a implante de prótese aórtica transcateter. O grau do RPP pós-procedimento foi avaliado segundo os critérios do VARC 2. Dividiu-se a população em grupo RPP ausente/RPP discreto e grupo RPP moderado/RPP grave. RESULTADOS: A média da idade foi de 82,5 ± 3,9 anos, 58,9% eram do sexo feminino e o EuroSCORE logístico foi de 23,6 ± 13,4. Houve queda do gradiente sistólico médio (54,7 ± 15,3 mmHg vs. 11,7 ± 4 mmHg; P < 0,01) e ganho da área valvar aórtica (0,66 ± 0,15 cm² vs. 1,8 ± 0,3 cm²; P < 0,01). Ao final do procedimento, 46,4% não apresentaram RPP, e RRP discreto ou moderado foi observado em 42% e 11,6% dos pacientes. Nenhum paciente apresentou RPP grave. A análise multivariada identificou sexo masculino [odds ratio (OR) 5,85, intervalo de confiança (IC] 1,29-26,7; P = 0,022), valvoplastia aórtica percutânea prévia (OR 18,44, IC 2,30-147,85; P = 0,006), fração de ejeção < 35% (OR 4,160, IC 1,014-17,064; P = 0,048) e presença de hipertensão pulmonar grave (OR 7,649, IC 1,86-31,51; P = 0,005) como preditores independentes de RPP moderado/grave. CONCLUSÕES: A incidência de RPP moderado/grave foi baixa e comparável à de outras casuísticas. Sexo masculino, antecedente de valvoplastia aórtica percutânea prévia, presença de hipertensão pulmonar grave e disfunção ventricular esquerda grave foram preditores independentes dessa complicação.
BACKGROUND: The incidence of paravalvular aortic regurgitation (PAR) seems higher among patients submitted to transcatheter aortic valve implantation and its potential association with an increased late mortality has raised concerns in the scientific community. Our objective was to evaluate the incidence and clinical impact of PAR and establish PAR predictors in our patient population. METHODS: Between July/2009 and February/2013, 112 patients were submitted to transcatheter aortic valve implantation. The degree of PAR after the procedure was assessed according to the VARC 2 criteria. The population was divided into no/mild PAR group and moderate/severe PAR group. RESULTS: Mean age was 82.5 ± 3.9 years, 58.9% were female and the logistic EuroSCORE was 23.6 ± 13.4. There was a decrease in the mean systolic gradient (54.7 ± 15.3 mmHg vs 11.7 ± 4 mmHg; P < 0.01) and a gain in the aortic valve area (0.66 ± 0.15 cm² vs 1.8 ± 0.3 cm²; P < 0.01). At the end of the procedure 46.4% did not have PAR, and mild or moderate PAR was observed in 42% and 11.6% of the patients. No patient presented severe PAR. Multivariate analysis identified male gender [odds ratio (OR) 5.85, confidence interval (CI] 1.29-26.7; P = 0.022), previous percutaneous aortic valvuloplasty (OR 18.44, CI 2.30-147.85; P = 0.006), ejection fraction < 35% (OR 4.160, CI 1.014-17.064; P = 0.048) and the presence of severe pulmonary hypertension (OR 7.649, CI 1.86-31.51; P = 0.005) as independent predictors of moderate/severe PAR. CONCLUSIONS: The incidence of moderate/severe PAR was low and comparable to other studies. Male gender, history of prior percutaneous aortic valvuloplasty, presence of severe pulmonary hypertension and severe left ventricular dysfunction were independent predictors of this complication.
Sujet(s)
Humains , Sondes cardiaques , Sténose aortique/complications , Sténose aortique/diagnostic , Implantation de valve prothétique cardiaque/mortalité , Insuffisance aortique/complications , Insuffisance aortique/diagnostic , Échocardiographie transoesophagienne/méthodes , Échocardiographie transoesophagienne , Études rétrospectivesRÉSUMÉ
INTRODUÇÃO: A intervenção coronária percutânea (ICP) em pontes de safena ainda representa um desafio à cardiologia intervencionista, pelas complicações agudas e pela escassez de dados referentes à efetividade tardia dos stents farmacológicos (SFs). MÉTODOS: Entre maio de 2002 e janeiro de 2013, pacientes submetidos a ICP com SF no Hospital do Coração foram incluídos no Registro DESIRE. Avaliamos os resultados de pacientes submetidos a ICP em pontes de safena (grupo 1), que foram comparados aos submetidos a ICP em vasos nativos (grupo 2). RESULTADOS: De um total de 4.655 pacientes, 311 foram incluídos no grupo 1 e 4.344, no grupo 2. O grupo 1 contou com pacientes mais idosos (68,4 ± 9,7 anos vs. 64 ± 11,2 anos; P < 0,01), com mais pacientes do sexo masculino (87,1% vs. 76,7%; P < 0,01) e com maior incidência de comorbidades. Angina instável foi a apresentação clínica mais frequente nesse grupo. Pacientes do grupo 1 receberam stents de maior calibre (3,18 ± 1,11 mm vs. 2,86 ± 0,43 mm; P < 0,01) e foram submetidos menos frequentemente a pré-dilatação (36,3% vs. 50,7%; P < 0,01) e a pós-dilatação (38,3% vs. 58,4%; P < 0,01). Apresentaram mais infarto agudo do miocárdio não-fatal na fase hospitalar (11,3% vs. 4,1%; P < 0,01) e mais eventos cardiovasculares adversos maiores na fase tardia (32,8% vs. 13,9%; P < 0,01), à custa de óbito cardíaco (7,7% vs. 3,2%; P = 0,02) e de revascularização da lesão-alvo (9% vs. 4,3%; P < 0,01). Trombose definitiva do stent foi mais frequente no grupo 1 (3,5% vs. 1%; P < 0,01). CONCLUSÕES: A despeito do inquestionável benefício dos SFs nos resultados tardios de ICP em pacientes complexos, o tratamento de pacientes com lesões em pontes de safena ainda permanece um desafio, com resultados agudos e tardios menos favoráveis que os de pacientes com lesões em vasos nativos.
BACKGROUND: Percutaneous coronary intervention (PCI) in saphenous vein grafts remains a challenge for interventional cardiology, due to acute complications and the lack of data on the late efficacy of drug-eluting stents (DESs). METHODS: Between May 2002 and January 2013, patients undergoing PCI with DES at Hospital do Coração were included in the DESIRE Registry. We evaluated the results of patients undergoing PCI in saphenous vein grafts (group 1), who were compared to those undergoing PCI in native vessels (group 2.) RESULTS: Of a total of 4,655 patients, 311 were included in group 1 and 4,344 in group 2. Group 1 included older patients (68.4 ± 9.7 years vs. 64 ± 11.2 years; P < 0.01), more frequently male (87.1% vs. 76.7%; P < 0.01) with a higher incidence of comorbidities. Unstable angina was the most frequent clinical presentation in this group. Group 1 patients received large caliber stents (3.18 ± 1.11 mm vs. 2.86 ± 0.43 mm; P < 0.01) and were less frequently submitted to pre-dilation (36.3% vs. 50.7%; P < 0.01) and post-dilation (38.3% vs. 58.4%; P < 0.01). They had a higher incidence of non-fatal acute myocardial infarction during hospitalization (11.3% vs. 4.1%; P < 0.01) and late major adverse cardiovascular events (32.8% vs. 13.9%; P < 0.01), at the expense of cardiac death (7.7% vs. 3.2%; P = 0.02) and target-lesion revascularization (9% vs. 4.3%; P < 0.01). Definitive stent thrombosis was more frequent in group 1 (3.5% vs. 1%; P< 0.01). CONCLUSIONS: Despite the unquestionable benefit of DESs in the late outcomes of PCI in complex patients, the treatment of patients with saphenous vein graft lesions remains a challenge, with less favorable acute and late results than in patients with native vessel lesions.
Sujet(s)
Humains , Mâle , Femelle , Angioplastie/méthodes , Angioplastie , Pontage aortocoronarien/méthodes , Pontage aortocoronarien , Endoprothèses à élution de substances , Veine saphène , Facteurs de risque , Resténose coronaire/complicationsRÉSUMÉ
INTRODUÇÃO: O tipo de proteção cerebral utilizado durante o implante de stent carotídeo é controverso em idosos. Nosso objetivo foi avaliar os resultados dos dispositivos de proteção embólica cerebral (PEC), proximal e distal, em pacientes > 70 anos de idade, por meio da ressonância magnética ponderada de difusão (RM-PD). MÉTODOS: Entre 2008 e 2011, 60 pacientes com indicação de stent carotídeo foram randomizados para PEC com Mo.Ma® ou Angioguard®, dos quais 26 tinham > 70 anos de idade. Os resultados da RM-PD realizada antes e 48 horas após o procedimento foram avaliados por neurologista independente e cego para o tipo de PEC utilizado. Foram analisados o número de novos focos isquêmicos, sua localização e o tamanho. RESULTADOS: Novos focos isquêmicos cerebrais foram encontrados em 8/12 (66,7%) pacientes do grupo Mo.Ma® e em 12/14 (85,7%) pacientes do grupo Angioguard® (P = 0,37). A maioria das lesões (> 90%) era ipsilateral à artéria tratada em ambos os grupos, e o tamanho das lesões foi < 0,5 cm na maioria dos casos. O número de lesões por paciente foi menor com o dispositivo Mo.Ma® (mediana [variação]: 3 [1 a 8] lesões vs. 15 [2 a 76] lesões; P < 0,001). Todos os pacientes que tiveram mais de 40 lesões pertenciam ao grupo Angioguard®. CONCLUSÕES: Mesmo utilizando PEC (proximal ou distal), novas lesões isquêmicas foram observadas em ambos os grupos em pacientes idosos. Proporcionalmente maior número de pacientes com Angioguard® teve novos focos isquêmicos se comparados aos pacientes do grupo Mo.Ma®. O dispositivo de PEC Mo.Ma® parece diminuir o número de lesões por paciente.
BACKGROUND: The type of cerebral protection used during carotid stenting in the elderly is controversial. Our objective was to evaluate the results of proximal and distal cerebral embolic protection devices (EPDs), in patients > 70 years through diffusion-weighted magnetic resonance imaging (DW-MRI). METHODS: Between 2008 and 2011, 60 patients with indication for carotid stenting were randomized to EPD with Mo.Ma® or Angioguard®, of which 26 patients were > 70 years of age. Results of DW-MRI performed before and 48 hours after the procedure were evaluated by an independent neurologist blinded to the type of EPD used. New ischemic lesions, their localization and size were analyzed. RESULTS: New cerebral ischemic lesions were found in 8/12 (66.7%) patients in the Mo.Ma® group and 12/14 (85.7%) patients in the Angioguard® group (P = 0.37). The vast majority of the lesions (> 90%) were ipsilateral to the treated artery in both groups and the size of the lesions was < 0.5 cm in most cases. The number of lesions per patient was lower with the Mo.Ma® device (median [variation]: 3 [1 to 8] lesions vs 15 [2 to 76] lesions; P < 0.001). All of the patients with more than 40 lesions were in the Angioguard® group. CONCLUSIONS: Despite the use of EPDs (proximal or distal), new ischemic lesions were observed in both groups in elderly patients. A proportionately larger number of patients with Angioguard® had new ischemic lesions when compared to those with Mo.Ma®. The Mo.Ma® device seems to decrease the number of lesions per patient.
Sujet(s)
Humains , Mâle , Femelle , Sujet âgé , Angiographie cérébrale/méthodes , Angiographie cérébrale , Sténose carotidienne/complications , Sténose carotidienne/diagnostic , Sujet âgé , Endoprothèses , Angioplastie/méthodes , Facteurs de risqueRÉSUMÉ
Relatamos série de 5 pacientes internados por síndrome coronária aguda, entre 2008 e 2010, nos quais a cinecoronariografia evidenciou dissecção coronária espontânea. A dissecção coronária espontânea é uma causa rara de infarto do miocárdio, mais comumente observada em indivíduos jovens e sem histórico de doenças cardiovasculares. O manejo ideal é incerto, principalmente pela limitada experiência clínica com essa entidade. A ultrassonografia intracoronária é uma ferramenta útil tanto para o diagnóstico da dissecção coronária espontânea como para guiar o tratamento percutâneo.
We report a series of five patients hospitalized due to acute coronary syndrome, from 2008 to 2010, in whom coronary angiography showed spontaneous coronary dissection. Spontaneous coronary artery dissection is a rare cause of acute myocardial infarction, most commonly seen in young individuals with no history of cardiovascular disease. The optimal management is uncertain, especially due to the limited clinical experience with this entity. Intravascular ultrasound is a useful tool to diagnose spontaneous coronary artery dissection as well as to guide percutaneous therapy.
Sujet(s)
Humains , Mâle , Adulte d'âge moyen , Angioplastie/méthodes , Circulation coronarienne/physiologie , Infarctus du myocarde/complications , Endoprothèses , Syndrome coronarien aigu/complications , Syndrome coronarien aigu/diagnostic , Diagnostic Clinique , Facteurs de risqueRÉSUMÉ
INTRODUÇÃO: A denervação simpática renal (DSR) é estratégia promissora no tratamento da hipertensão arterial resistente. Nenhum estudo avaliou o efeito da DSR na qualidade de vida em nosso meio, objetivo deste estudo. MÉTODOS: O questionário EuroQol-5 Dimensions (EQ-5D-5L) foi utilizado para avaliar a qualidade de vida de 10 pacientes submetidos a DSR, sendo aplicado antes e 3 meses após o procedimento. RESULTADOS: A média de idade foi de 47,3 ± 12 anos e 90% dos pacientes eram do sexo feminino. A pressão arterial basal foi de 187 ± 37,5/104 ± 18,5 mmHg e o número de anti-hipertensivos utilizados foi de 7,6 ± 1,3. Antes do procedimento, o valor atribuído ao estado de saúde foi de 37,5 ± 22,7, aumentando aos 3 meses para 70,5 ± 20,9 (P = 0,01). No seguimento, além da diminuição do número de anti-hipertensivos (7,6 ± 1,3 vs. 6 ± 2,2; P = 0,05), foi observada tendência a queda dos níveis da pressão sistólica (187 ± 36 mmHg vs. 170 ± 44 mmHg; P = 0,10) e da pressão diastólica (104 ± 18 mmHg vs. 98 ± 20 mmHg; P = 0,20). A melhora do estado de saúde resultou da redução de problemas relacionados a mobilidade, atividades usuais, dor/desconforto e ansiedade/depressão. A magnitude da redução da pressão arterial não se associou à melhora da qualidade de vida em todos os pacientes. Por outro lado, aqueles que experimentaram redução do número de anti-hipertensivos relataram melhor estado de saúde. CONCLUSÕES: Hipertensos resistentes apresentam baixos escores de estado de saúde. A DSR apontou melhora da qualidade de vida na maioria dos pacientes. Estudos maiores são necessários para confirmar benefícios consistentes.
BACKGROUND: Renal sympathetic denervation (RSD) is a promising strategy in the treatment of resistant hypertension. No studies have assessed the effect of RSD on quality of life in our country, which was the aim of this study. METHODS: The EuroQol-5 Dimensions questionnaire (EQ-5D-5L) was chosen to evaluate quality of life in 10 patients undergoing RSD, and it was applied before and 3 months after the procedure. RESULTS: Mean age was 47.3 ± 12 years and 90% of the patients were female. Baseline blood pressure was 187 ± 37.5/104 ± 18.5 mmHg and the number of antihypertensive drugs was 7.6 ± 1.3. Before the procedure, the value assigned to health status was 37.5 ± 22.7, increasing at 3 months to 70.5 ± 20.9 (P = 0.01). In the follow-up, in addition to a decrease in the number of antihypertensive drugs (7.6 ± 1.3 vs. 6 ± 2.2; P = 0.05), a trend towards reduced levels of systolic blood pressure (187 ± 36 mmHg vs 170 ± 44 mmHg; P = 0.10) and diastolic blood pressure (104 ± 18 mmHg vs 98 ± 20 mmHg; P = 0.20) was observed. Health status improvement resulted from a reduction of problems related to mobility, usual activities, pain/discomfort and anxiety/depression. The magnitude of blood pressure reduction was not associated with improved quality in all of the patients. On the other hand, those who had a decrease in the number of antihypertensive drugs reported a better health status. CONCLUSIONS: Patients with resistant hypertension have poor health status scores. RSD improved quality of life in most patients. Further studies are required to confirm consistent benefits.