Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtre
Ajouter des filtres








Gamme d'année
1.
Indian J Ophthalmol ; 2020 Feb; 68(13): 42-46
Article | IMSEAR | ID: sea-197903

Résumé

Purpose: To evaluate the sensitivity and specificity of smartphone-based nonmydriatic (NM) retinal camera in the detection of diabetic retinopathy (DR) and sight-threatening DR (STDR) in a tertiary eye care facility. Methods: Patients with diabetes underwent retinal photography with a smartphone-based NM fundus camera before mydriasis and standard 7-field fundus photography with a desktop mydriatic fundus camera after mydriasis. DR was graded using the international clinical classification of diabetic retinopathy system by two retinal expert ophthalmologists masked to each other and to the patient's identity. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) to detect DR and STDR by NM retinal imaging were assessed. Results: 245 people had gradable images in one or both eyes. DR and STDR were detected in 45.3% and 24.5%, respectively using NM camera, and in 57.6% and 28.6%, respectively using mydriatic camera. The sensitivity and specificity to detect any DR by NM camera was 75.2% (95% confidence interval (CI) 68.1–82.3) and 95.2% (95%CI 91.1–99.3). For STDR the values were 82.9% (95% CI 74.0–91.7) and 98.9% (95% CI 97.3–100), respectively. The PPV to detect any DR was 95.5% (95% CI 89.8–98.5) and NPV was 73.9% (95% CI 66.4–81.3); PPV for STDR detection was 96.7% (95% CI 92.1–100)) and NPV was 93.5% (95% CI 90.0–97.1). Conclusion: Smartphone-based NM retinal camera had fairly high sensitivity and specificity for detection of DR and STDR in this clinic-based study. Further studies are warranted in other settings.

2.
Article Dans Anglais | IMSEAR | ID: sea-164522

Résumé

The study conducted in retrospective manner in 150 bedded Government Victoria Hospital Maternity Hospital affiliated to Andhra Medical College, Visakhapatnam, Andhra Pradesh. The rates and indications of primary and repeat Cesarean section rate was compared with 2004 and 2009 Cesarean rates. In our study, the Cesarean section rate was 25.66%. There is an increase in the CS rate over last decade from 16.14% in 2004, 20.33% in 2009 to 25.66% in 2014. The main contribution to this rise in CS is due to increase in numbers of repeat sections. CS become increasingly the procedure of choice in high risk pregnancies to prevent perinatal morbidity and mortality. This has become possible due to improved patient care, availability of effective antibiotics, blood transfusion services safer anesthesia, improved surgical technique and sophisticated neonatal care services.

3.
Indian J Exp Biol ; 2000 Nov; 38(11): 1168-71
Article Dans Anglais | IMSEAR | ID: sea-61076

Résumé

The random amplified polymorphic DNA (RAPD) profile of A. azollae strains isolated from four different Azolla cultures was studied by using different primers. The objective of this study was to determine whether polymerase chain reaction (PCR) with different primers could differentiate the isolated A. azollae strains from one another. The primers amplified specific sequences of the isolates and generated fingerprinting pattern characteristic of each isolate. Clear polymorphism was noticed among all the strains which depends on the primer sequence.


Sujets)
Anabaena/classification , Séquence nucléotidique , Amorces ADN , Plantes/microbiologie , Réaction de polymérisation en chaîne , Technique RAPD
SÉLECTION CITATIONS
Détails de la recherche