RÉSUMÉ
PURPOSE: We compared the measurements of anterior chamber depth (ACD) and anterior chamber angle (ACA) using ultrasound biomicroscopy (UBM) in the sitting position compared with IOL Master(R), Pentacam(R), and Spectralis optical coherence tomography (OCT) to evaluate the clinical usefulness of UBM in the sitting position. METHODS: We evaluated 92 eyes in 47 healthy adults. ACD was measured by IOL Master(R), Pentacam(R), and UBM. ACA was measured using Pentacam(R), UBM, and Spectralis OCT. UBM was performed in the sitting position using bag/balloon technology. Measured values were compared statistically. RESULTS: ACD measured by IOL Master(R), Pentacam(R), and UBM was 3.57 +/- 0.32 microm, 3.64 +/- 0.33 microm and 3.51 +/- 0.32 microm, respectively. UBM measurements of ACD were significantly shallower than with the other methods (p 0.8, p 0.05). There was strong correlation between UBM and Spectralis OCT (r = 0.957) but moderate correlation between Pentacam(R) and UBM and Pentacam(R) and Spectralis OCT (r = 0.557, 0.571, respectively, p < 0.05). Specifically, ACA of the superior quadrant showed a low correlation between Pentacam(R) and UBM and Pentacam(R) and Spectralis OCT (r = 0.257, 0.295, respectively). CONCLUSIONS: ACD measured by UBM in the sitting position was shallower compared to the other methods; however, ACD measured by IOL Master(R), Pentacam(R), and UBM showed significant correlations among the methods. The mean ACA measured by Pentacam(R), UBM, and Spectralis OCT showed no significant differences. Due to the high correlation of ACA measurements between UBM and Spectralis OCT in the present study, UBM is expected to be a good tool for measuring anterior segment parameters.
Sujet(s)
Adulte , Humains , Chambre antérieure du bulbe oculaire , Microscopie acoustique , Tomographie par cohérence optiqueRÉSUMÉ
The publisher wishes to apologize for incorrectly displaying the author (Sung Woon Moon) name. We correct his name from Sung Woon Moon to Sung Won Moon.
RÉSUMÉ
BACKGROUND/AIMS: The rapid urease test (RUT) is an invasive method to diagnose Helicobacter pylori infection, which relies on the acquisition and examination of gastric antrum and body tissues. We determined and compared the efficacy of RUT when the tissues were examined separately or after being combined. METHODS: Two hundred and fourteen patients were included and underwent esophagogastroduodenoscopy from July 2008 to June 2010. The separate test was defined as evaluating the status of infectivity of H. pylori from the antrum and body separately; whereas the united test was carried out putting both tissues from the antrum and body in the same RUT kit. All RUTs were read by a single observer 1, 3, 6, 12, and up to 24 hours later. We also got two biopsy specimens stained with hematoxylin and eosin and quantified H. pylori density was calculated on a scale of 0 to 3. RESULTS: Overall positivity for H. pylori was 137 (64%) for the separate test and 148 (69.2%) for the united test (p<0.01). The mean time to a positive test was 3.58 hours for the separate test and 1.69 hours for the united test (p<0.01). The correlation between the time to positive RUT and the severity of histology showed r=+0.556 for the antrum (p<0.01) and r=+0.622 for the body (p<0.01). CONCLUSIONS: Combining tissues prior to RUT enhances the detection of H. pylori, as compared with the examination of separate tissues, and shortens the time to develop a positive reaction by approximately 50%. These diagnostic advantages are also accompanied by increased cost-savings.
Sujet(s)
Humains , Biopsie , Endoscopie digestive , Éosine jaunâtre , Helicobacter , Helicobacter pylori , Hématoxyline , Antre pylorique , UreaseRÉSUMÉ
PURPOSE: To compare macular thickness measurements obtained from time domain optical coherence tomography (TD-OCT) and 2 spectral domain (SD) OCTs and to evaluate their repeatability and agreement in normal subjects and diabetic macular edema patients. METHODS: Fifty-four healthy, normal subjects and 26 diabetic macular edema patients were participated in this study. In a randomly selected eye from each subject, two serial macular measurements were obtained from TD-OCT (Stratus OCT) and SD-OCTs (Cirrus HD-OCT, Spectralis HRA+OCT) by an experienced technician in random order. Nine areas of macular thickness map and repeatabilities obtained by the 3 OCTs were compared. RESULTS: In relative repeatability, SD-OCT showed better results overall compared to TD-OCT. Macular thickness was greatest in the Spectralis HRA+OCT in both normal subjects and diabetic macular edema patients, followed by Cirrus HD-OCT and Stratus OCT. In normal subjects, regardless of the type of comparison between the machines there was a statistically significant difference in all 9 areas. CONCLUSIONS: While the TD-OCT and the 2 SD-OCTs are reliable for macular thickness measurement, SD-OCT has better measurement repeatability compared with TD-OCT. Because macular measurements obtained from the 3 OCT systems cannot be interchanged, an effort should be made to standardize the measurement of each system.
Sujet(s)
Humains , Oeil , Oedème maculaire , Tomographie par cohérence optiqueRÉSUMÉ
PURPOSE: To present a case of peripheral infiltrative keratitis mimicking infectious keratitis on the flap margin and limbus, which appeared on the first postoperative day after the laser in situ keratomileusis (LASIK). METHODS: A 36-year-old woman who underwent uneventful bilateral simultaneous LASIK developed multiple round infiltrate along the flap margin reaching to limbus from the 11 o'clock to 6 o'clock area in both eyes. RESULTS: The flap was lifted and irrigation was performed with antibiotics. but infiltration seemed to appear again. The infiltrate was more concentrated at the periphery and was extended to the limbus. Direct smear and culture for bacteria and fungus were negative. Topical prednisolone acetate 1% eye drops was added, infiltrative condition was resolved. CONCLUSIONS: LASIK induced peripheral infiltrative keratitis, in which infectious origin was ruled out, is reported.