Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 1 de 1
Filtrer
Plus de filtres








Gamme d'année
1.
Tropical Biomedicine ; : 64-69, 2024.
Article de Anglais | WPRIM | ID: wpr-1036562

RÉSUMÉ

@#COVID-19, caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), remains a global health threat. Timely identification of infected cases is important for appropriate patient management and the control of viral spread. Simple and cost-effective tests are required to increase access to testing and early case detection. Here, we describe a colorimetric reverse transcription-loop-mediated isothermal amplification (RT-LAMP) method to detect SARS-CoV-2. The RT-LAMP could amplify the orf1ab sequence detectable by visual color change within 45 min at 63 °C. The limit of detection (LoD) for SARS-CoV-2 RNA was less than 100 copies (13.36) per reaction with no cross-amplification with other related viruses. Clinical evaluation using leftover RNA samples extracted from 163 nasopharyngeal swab specimens showed perfect agreement in negative (n = 124) and positive samples with cycle thresholds (Ct) < 34 cycles (n = 33) detected by real-time reverse transcription-polymerase chain reaction (RT-PCR), targeting RdRp and N genes as a reference. Overall, the diagnostic accuracy, sensitivity, specificity, positive and negative predictive values of RT-LAMP in testing were 96.32% (95% CI: 92.16-98.64%), 84.62% (95% CI: 68.47-94.14%), 100% (95% CI: 97.07-100.0%), 100% (95% CI: 89.42-100.0%), and 95.38% (95% CI: 90.22-98.29), respectively. This RT-LAMP assay is simple and reliable, with the potential to be an alternative for the rapid detection of SAR-CoV-2 with minimal time and fewer resources compared to real-time RT-PCR.

SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE