Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 25
Filtre
1.
Article | IMSEAR | ID: sea-225704

Résumé

Background:Objective of the study was to provide insight on the immune response in patients of rheumatic heart disease, mitral stenosis and evaluation of various cytokines in pulmonary hypertension secondary to rheumatic heart disease.Methods:Total 163 subjects, more than 18 year of age, were enrolled in this study. 84 subjects with rheumatic mitral stenosis (group A) diagnosed on two-dimensional echocardiography (2D echo)and 79 normal healthy volunteers(group B). Patients with mitral stenosis were further divided into subgroups based on severity of mitral stenosis [mitral valve area (MVA >1 cm2 and MVA <1 cm2)(subgroup Aa and Ab)]and presence or absence of pulmonary hypertension [pulmonary arterial systolic pressure (PASP >36 mm Hg)(subgroup Ac and Ad)]. Interleukins IL-6, IL-10, IL-18, tumour necrosis factor alpha (TNF-?)andhigh-sensitivity C-reactive protein (hs-CRP)levels were assessed in both groups.Results:Mean IL-6, IL-10, IL-18, TNF-? and hs-CRP in group A and group B was 6.57�53 and 2.73�p?0.001), 8.185�8 and 3.51�86(p?0.001), 136.31�.0 and 47.96�76(p?0.001), 21.26�.59 and 5.36�57(p?0.001), 4.69�3 and 2.63�22(p?0.008) respectively. On subgroup analysis mean TNF-? in subgroup Aa was 20.71�.84, while in subgroup Ab was 7.56�93 (p?0.001). Mean IL-10 in subgroup Ac and Ad was 8.74�29 and 7.47�82, respectively. Differences in levels of other cytokines in these subgroups were not found statistically significant.Conclusions:This study finds increased IL-6, IL-10, IL-18, TNF-? and hs-CRP levels in subjects with rheumatic mitral stenosis. Subjects with severe mitral stenosis had increased TNF-? levels. Subjects of mitral stenosis having pulmonary hypertension had increased IL-10 levels.

2.
Indian Heart J ; 2018 Nov; 70(6): 922-933
Article | IMSEAR | ID: sea-191643

Résumé

Radial access for cardiac catheterization and intervention in India has been growing steadily over the last decade with favorable clinical outcomes. However, its usage by interventional cardiologists varies greatly among Indian operators and hospitals due to large geographic disparities in health care delivery systems and practice patterns. It also remains unclear whether the advantages, as well as limitations of transradial (TR) intervention (as reported in the western literature), are applicable to developing countries like India or not. An evidence-based review involving various facets of radial procedure for cardiac catheterization, including practical, patient-related and technical issues was conducted by an expert committee that formed a part of Advancing Complex CoronariES Sciences through TransRADIAL intervention (ACCESS RADIAL™) Advisory Board. Emerging challenges in redefining TR management based on evidence supporting practices were discussed to formulate these final recommendations through consensus.

3.
Indian Heart J ; 2008 May-Jun; 60(3): 254-6
Article Dans Anglais | IMSEAR | ID: sea-4440

Résumé

Aortopulmonary window is a rare congenital heart disease occurring in 0.2-0.6% of all patients with congenital heart disease. It is usually nonrestrictive and is conventionally treated surgically at an early age to prevent the development of pulmonary vascular obstructive disease. In 10% of the patients, it is restrictive and case reports of its percutaneous closure are mostly limited to these patients. We report percutaneous device closure of nonrestrictive AP window in a 4 months old, 4 kg child. To the best of our knowledge this is the youngest child to have undergone percutaneous device closure of an AP window.


Sujets)
Aorte/malformations , Communication aortopulmonaire/thérapie , Occlusion par ballonnet/méthodes , Échocardiographie , Cathétérisme cardiaque/méthodes , Humains , Nourrisson , Mâle
6.
Indian Heart J ; 2005 Mar-Apr; 57(2): 170-1
Article Dans Anglais | IMSEAR | ID: sea-6010

Résumé

Coronary perforation during percutaneous coronary interventions is a rare but dreadful complication. While coronary perforation involving large vessels are managed successfully by covered stents, small distal vessel perforation is usually managed by prolonged balloon inflation or embolization of gel foam/thrombogenic metallic coils. We describe a case, where perforation of a small ventricular branch of the right coronary artery was successfully occluded by packing it with pieces of thrombogenic floppy tips of used coronary angioplasty guidewires instead of conventional metallic coils.


Sujets)
Angine de poitrine/thérapie , Angioplastie coronaire par ballonnet/effets indésirables , Coronarographie , Vaisseaux coronaires/traumatismes , Diagnostic différentiel , Embolisation thérapeutique , Humains , Maladie iatrogène , Mâle , Adulte d'âge moyen , Rupture/diagnostic
9.
Indian Heart J ; 2004 Jul-Aug; 56(4): 328-32
Article Dans Anglais | IMSEAR | ID: sea-3235

Résumé

We describe a new technique of sealing cardiac perforation resulting in cardiac tamponade during transvenous mitral commissurotomy by percutaneous instillation of cyanoacrylate glue at the perforation site, thus avoiding surgery.


Sujets)
Adulte , /effets indésirables , Tamponnade cardiaque/étiologie , Cyanoacrylates/administration et posologie , Femelle , Septum du coeur/traumatismes , Hémodynamique , Humains , Instillation de médicaments , Polymères
10.
Indian Heart J ; 2004 May-Jun; 56(3): 235-8
Article Dans Anglais | IMSEAR | ID: sea-5680

Résumé

We report an unusual complication of a 25 mm long stent, which did not expand at all for 1 mm in its proximal segment, while rest of the 24 mm length of the stent got fully expanded. Repeated attempts to expand the extremely focal unexpanded part of the stent at high pressure led to rupture of the stent balloon and its entrapment. We failed to retrieve the balloon using various techniques and the patient had to be sent for coronary artery bypass graft surgery.


Sujets)
Angor instable/chirurgie , Angioplastie coronaire par ballonnet , Sténose pathologique/étiologie , Pontage aortocoronarien , Vaisseaux coronaires/anatomopathologie , Services des urgences médicales , Humains , Mâle , Adulte d'âge moyen , Complications postopératoires/étiologie , Endoprothèses/effets indésirables
12.
Indian Heart J ; 2004 Mar-Apr; 56(2): 158-62
Article Dans Anglais | IMSEAR | ID: sea-6102

Résumé

Percutaneous transvenous mitral commissurotomy using Inoue balloon is an effective procedure for the management of patients with juvenile mitral stenosis. Inability to cross the mitral valve by the Inoue balloon catheter is one of the important reasons for failure of the procedure. We describe a new technique, facilitating left atrium to left ventricular entry using double loop of Inoue balloon catheter in a child with small left atrium.


Sujets)
Angiographie/méthodes , /instrumentation , Enfant , Échocardiographie-doppler , Études de suivi , Cathétérisme cardiaque/méthodes , Humains , Mâle , Sténose mitrale/étiologie , Rhumatisme cardiaque/complications , Appréciation des risques , Résultat thérapeutique
13.
Indian Heart J ; 2004 Mar-Apr; 56(2): 132-9
Article Dans Anglais | IMSEAR | ID: sea-5591

Résumé

BACKGROUND: Transcatheter closure of coronary artery fistulas has emerged as a successful alternative to surgery. We describe various techniques and short-term findings in 15 patients who were taken up for transcatheter closure of these fistulas. METHODS AND RESULTS: Fifteen patients (aged 2-55 years; 12 males) with coronary artery fistulas underwent percutaneous transcatheter closure between June 1997 and December 2002. Site of origin of these fistulas were: right coronary artery in 7, left anterior descending coronary artery in 4, left main coronary artery in 2 and left circumflex coronary artery in 2 patients. Drainage site of these fistulas were: right ventricle in 9, right atrium in 4 and pulmonary artery in 2 patients. Out of these 15 fistulas, 14 were congenital and one was iatrogenically produced following inadvertent cutting balloon angioplasty of a septal perforator in a patient with chronic total occlusion of left anterior descending coronary artery. Various occlusion devices used to close these fistulas were: conventional metallic coils in 10, floppy tips of coronary angioplasty guidewires in 2, Amplatzer duct occluder in 1 and Amplatzer septal occluder in 2 patients. One of our patients had a coronary artery fistula draining by two openings into the right atrium, both of which were successfully closed using 2 Amplatzer duct occluders. Check angiogram after the procedure revealed complete occlusion in 13 (86.6%) and small residual flow in 2 patients. Follow-up studies at 3-55 months (mean 18 months) showed complete abolition of shunt in all patients with no evidence of recanalization leading to recurrence of shunt. CONCLUSION: Transcatheter closure of coronary artery fistulas is feasible and safe in the anatomically suitable vessels. Use of floppy tips of coronary angioplasty guidewires reduces the cost of the procedure significantly. which is an important consideration in developing countries like India.


Sujets)
Adolescent , Adulte , Fistule artérioartérielle/diagnostic , Enfant , Enfant d'âge préscolaire , Coronarographie/méthodes , Anomalies congénitales des vaisseaux coronaires/diagnostic , Échocardiographie , Électrocardiographie , Embolisation thérapeutique/instrumentation , Femelle , Études de suivi , Cathétérisme cardiaque , Humains , Inde , Mâle , Adulte d'âge moyen , Radiologie interventionnelle/méthodes , Études rétrospectives , Appréciation des risques , Études par échantillonnage , Indice de gravité de la maladie , Résultat thérapeutique
14.
Indian Heart J ; 2004 Jan-Feb; 56(1): 61-3
Article Dans Anglais | IMSEAR | ID: sea-6061

Résumé

We report the case of a female patient who presented with signs and symptoms of tricuspid stenosis. Echocardiography revealed a sessile mass on the tricuspid valve. A diagnosis of primary cardiac tumor was made but histopathologic examination revealed the mass to be an organized thrombus. Subsequent serological tests showed elevated titers of anticardiolipin antibodies in the absence of any associated disease. This case highlights an unusual presentation of the primary antiphospholipid syndrome.


Sujets)
Adulte , Syndrome des anticorps antiphospholipides/complications , Femelle , Cardiopathies/étiologie , Humains , Thrombose/étiologie , Sténose tricuspidienne/étiologie
17.
Indian Heart J ; 2003 Nov-Dec; 55(6): 643-5
Article Dans Anglais | IMSEAR | ID: sea-5533

Résumé

Stenting is the treatment of choice for treating stenotic renal ostial lesions. During the stenting of an ostial lesion in a renal artery with post-stenotic dilatation, we were faced with the problems of unavailability of a balloon of appropriate length and diameter, and determining the real reference vessel diameter. The problem was solved by a simple technique.


Sujets)
Adulte , Angioplastie par ballonnet/méthodes , Sténose pathologique/thérapie , Dilatation , Humains , Hypertension rénovasculaire/étiologie , Mâle , Occlusion artérielle rénale/complications , Endoprothèses
18.
Indian Heart J ; 2003 Jul-Aug; 55(4): 368-9
Article Dans Anglais | IMSEAR | ID: sea-6105

Résumé

Occlusion of a septal perforator branch alone, without the involvement of the left anterior descending coronary artery, leading to acute myocardial infarction is unusual. We report a case in which an isolated severely stenotic thrombus-containing first septal artery causing intractable post-myocardial infarction angina was successfully dilated and stented.


Sujets)
Angine de poitrine/étiologie , Coronarographie , Septum du coeur/imagerie diagnostique , Humains , Mâle , Adulte d'âge moyen , Infarctus du myocarde/complications , Endoprothèses
19.
Ann Card Anaesth ; 2003 Jul; 6(2): 169-70
Article Dans Anglais | IMSEAR | ID: sea-1573
SÉLECTION CITATIONS
Détails de la recherche