Journal of Practical Radiology ; (12): 650-654,662, 2015.
Article Dans Chinois | WPRIM | ID: wpr-601185

Résumé

Objective To explore the feasibility of “double low ”(low tube voltage and low contrast agent concentration)imaging technology of dual-source computed tomography (DSCT)in coronary angiography for low-weight patients.Methods 60 patients (BMI≤25 kg/m2 )who underwent coronary CT angiography (CCTA)on DSCT scanner were divided randomly into 2 groups:group A was “double low”group (n = 30,tube voltage = 80 kVp,using sinogram affirmed iterative reconstruction technology and 270 mg I/mL concentration of contrast agent);Group B was conventional group (n=30,tube voltage=120 kVp,using filtered back projection technology and 350 mg I/mL concentration of contrast agent).Adaptive cardiosequence prospective ECG-gated technology (CorAdSeq)was applied in both the groups,The collecting phase was 65%-75% RR interval (when heart rate<70 beats per mi-nute)or 40%-50% RR interval (when heart rate≥70 beats per minute).Subjective and objective methods were applied to evaluate the image quality.The image quality and.radiation dose were compared between the “double low”group and the conventional group by using SPSS 1 9.0 software.The differences between measurement data were analyzed by using independent samples t-test.Results The effective dose with size specific dose estimates (EDssde)of group A(1.22±0.31)mGy/cm was significantly lower than that of group B (3.44±0.80)mGy/cm with P <0.001.Contrast-noise ratio,signal-noise ratio and CT value of group A were signifi-cantly higher than those of group B (all P <0.05 ).Conclusion Compared with conventional DSCT coronary angiography,“double low”DSCT coronary scanning proposal for low-weight patients can significantly reduce the radiation dose and the amount of contrast agent,and the image quality can meet the needs of clinical diagnosis.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 326-328, 2012.
Article Dans Chinois | WPRIM | ID: wpr-427083

Résumé

Objective To study the image quality and radiation dose in dual-source CT cerebral angiography with prospective ECG-triggered sequence mode (step-and-shoot,SAS).Methods A total of forty-three patients with clinically suspected cerebral vascular disease underwent cerebral CT angiography with prospective ECG-triggering (step-and-shoot,SAS).Data acquisition was at 60% R-R interval of the ECG presentation mode.The post-processing included maximum intensity projection (MIP),multiplanar reformation (MPR) and volume rendering (VR).The CTA image quality,radiation dose and rates of excellent images were evaluated.Results The CTA image quality score was 4.72 ± 0.50 and 97.7% (42/43) patients had excellent CTA images.The average effective dose of SAS-CTA was (0.22 ± 0.01 )mSv,which was lower by 76.31% than that of DE-CTA.Conclusions Prospective ECG-triggering sequence could be used in cerebral angiography with a significant reduction in radiation dose and diagnostic image quality.

3.
Chinese Journal of Radiology ; (12): 481-485, 2011.
Article Dans Chinois | WPRIM | ID: wpr-415507

Résumé

Objective To compare the quality and radiation doses of coronary artery angiography under the natural heart rate condition between Flash spiral heart mode and prospective electrocardiogramtriggering sequence mode using dual-source,in order to choose personalized low doses of coronary artery scanning mode.Methods Sixty patients who underwent coronary angiography(CTA)on a 128-slice,dualsource CT scanner were divided into 2 group i.e,group A(27cases)and group B(33 cases).Flash spiral heart scan mode was employed for group A.Inclusion criteria included:heart rate75 bpm),date acquisition was set at 30%-50%of the R-R interval. (3)At the arrhythmias,premature beat,fibrillation atrial,date acquisition was set at 20%-90%of the R-R interval.In both gronps,patients with a BMI≥25.0kg/m2 were examined with a tube voltage of 120 kV.while the other patients with a BMI<25.0 kg/m2 were examined with a tube voltage of 100 kV.The BMl was(24.6±1.0)kg/m2 in group A,while that was (24.6±0.9)kg/m2 in group B.In both groups,all images were transferred to the workstation for further processing and analysis.The imaging quality of coronary artery segments and the radiation dose were compared with t test.Results A total of 336 coronary artery segments were evaluated in group A and 412 segments were evaluated in group B.The imaging quality of coronary artery segments were scored.Excellent or good was achieved in 98.2%(330 of 336)artery segments in group A,and that was 98.1%(404 of 412)in group B.There was no statistical difference in imaging quality between the two groups(t=0.513,P=0.608).The average effective dose was(0.74±0.29)mSv in group A,whereas that was(3.67±1.37)mSv in group B.There was a significant difference between the two groups(t=-10.858,P=0.000).Conclusions The personalized low doses coronary artery scanning mode can substantially reduce radiation damage while preserving good imaging quality.

4.
Chinese Journal of Radiology ; (12)2001.
Article Dans Chinois | WPRIM | ID: wpr-555909

Résumé

Objective To evaluate the role of dynamic contrast-enhanced magnetic resonance imaging (MRI) in the diagnose of prostatic cancer and benign prostatic hyperplasia (BPH), and to determine the correlation between dynamic MRI findings with angiogenesis.Methods Thirty-two cases of prostatic cancer and 40 cases of BPH underwent dynamic contrast-enhanced MRI.All the patients in this study were diagnosed by histopathology.The results of dynamic contrast-enhanced MRI were evaluated by early-phase enhancement parameters and time-signal intensity curves (SI-T curves), and the curves were classified according to their shapes as type Ⅰ, which had steady enhancement; type Ⅱ, plateau of signal intensity; and type Ⅲ, washout of signal intensity.The pathologic specimens of region of interest (ROI) were obtained, and HE staining, immunohistochemical vascular endothelial growth factor (VEGF), and microvessel density (MVD) measurements were performed.The relationships among dynamic contrast-enhanced MRI features, VEGF, and MVD expression were analyzed.Results In the early-phase enhancement parameters of dynamic contrast-enhanced MRI, onset time,maximum signal intensity, and early-phase enhancement rate differed between prostatic cancer and BPH(P