Singapore medical journal ; : 226-236, 2023.
Article Dans Anglais | WPRIM | ID: wpr-984191

Résumé

The COVID-19 global pandemic has overwhelmed health services with large numbers of patients presenting to hospital, requiring immediate triage and diagnosis. Complications include acute respiratory distress syndrome, myocarditis, septic shock, and multiple organ failure. Point of care ultrasound is recommended for critical care triage and monitoring in COVID-19 by specialist critical care societies, however current guidance has mainly been published in webinar format, not a comprehensive review. Important limitations of point of care ultrasound include inter-rater variability and subjectivity in interpretation of imaging findings, as well as infection control concerns. A practical approach to clinical integration of point of care ultrasound findings in COVID-19 patients is presented to enhance consistency in critical care decision making, and relevant infection control guidelines and operator precautions are discussed, based on a narrative review of the literature.


Sujets)
Humains , COVID-19/complications , SARS-CoV-2 , Systèmes automatisés lit malade , Systèmes d'aide à la décision clinique , Échographie
2.
Singapore medical journal ; : 432-435, 2019.
Article Dans Anglais | WPRIM | ID: wpr-776948

Résumé

INTRODUCTION@#Pulse oximetry is the standard monitoring technique of functional oxygen saturation (SpO). As the use of fingernail polish has been described to alter SpO readings, its removal is commonly recommended prior to measurement. Gel-based manicures have gained popularity in recent years due to their attractiveness and longevity. However, the removal of gel nail polish requires a specialised procedure. Valuable time and resources can be saved if removal can be avoided. To our knowledge, there are no available studies on the effect of gel-based manicures on pulse oximetry readings. Hence, we evaluated the effect with two oximeters, using different technology and wavelength combinations.@*METHODS@#17 healthy female adult volunteers were recruited for this single-blind randomised controlled trial. Subjects with hypothermia, hypotension, poor plethysmographic waveform and nail pathology were excluded. Colours tested were: black, purple, navy blue, green, light blue, white, yellow, orange, pink and red. Pulse oximetry was measured at 15- and 30-second intervals using two different pulse oximeters, the Philips M1191BL and Masimo SET®. Means were compared using paired t-tests.@*RESULTS@#Using the Masimo oximeter, light blue (ΔM = 0.97% ± 0.96%; p = 0.001) and orange (ΔM = 0.76 ± 1.17%; p = 0.016) gel nail polish resulted in a statistically significant increase from baseline SpO readings. With the Philips oximeter, the limits of agreement ranged from 2% for pink to 17% for black, indicating imprecision.@*CONCLUSION@#Gel-based manicures can result in overestimations of actual readings, delaying detection of hypoxaemia. Gel nail polish should be routinely removed or an alternative monitoring technique sought.

SÉLECTION CITATIONS