Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtre
Ajouter des filtres








Gamme d'année
1.
Chinese Journal of Blood Transfusion ; (12): 478-482, 2023.
Article Dans Chinois | WPRIM | ID: wpr-1004810

Résumé

【Objective】 To develop a quick and accurate crossmatching test technology without the power equipment and additional reagents before blood transfusion, so as to improve the timeliness and safety of blood transfusion treatment in sudden situations as war or natural disasters. 【Methods】 The irregular antibodies quickly promote coagulants (QPC) were used as the reaction medium reagent. The 200 μL QPC were wrapped in the bursts bead and preset within different recess of the detection tubes. The bursts beads were squeezed with the reagent left in the well, then the blood samples were dropped in the main(recipient plasma: 200 μL, donor 3%—5% RBC: 100 μL) and secondary(donor plasma: 200 μL, recipient 3%—5% RBC: 100 μL)reaction grooves. The result interpretated by hand wrestling or 1 500 g centrifugation of 15 seconds. Meanwhile, the comparing experiments with the prior methods were implemented to evaluate the method’s reliability. 【Results】 The results of the bursting reagent, being stored at 37℃ for one week, were consistent with those of the freshly prepared cross-matching reagent, indicating that the bursting reagent was practical in the field and had good stability at normal temperature. No statistical difference between the sensitivity and the results of the microcolumn gel method was noticed by paired data t test (P>0.05). The parallel cross matching tests of 50 clinical samples were performed by microcolumn gel method and coagulant-bursting technique; the Kappa value was 0.973 2, and irregular antibodies were detected in 2 cases, with concordance rate at 100%, showing good consistency. 【Conclusion】 The improved method is simple and fast, and also safe and reliable for compatibility testing before blood transfusion, which is especially suitable for the field rescue of the wounded in wartime and sudden natural disasters, and is worthy of popularization.

2.
Chinese Journal of Blood Transfusion ; (12): 598-600, 2023.
Article Dans Chinois | WPRIM | ID: wpr-1004792

Résumé

【Objective】 To analyze the causes of a case of hemolytic disease of the fetus and newborn (HDFN),and investigate the genetic background of maternal Rh deletion D--formation. 【Methods】 Blood samples of maternal and fetus were collected, and ABO blood typing, Rh blood typing, antibody screening and identification test were performed to explore the blood group serological characteristics of Rh deletion type D--, and Rh gene sequence was performed on parturient. 【Results】 The maternal blood group was identified to be O type, D--, and the anti-Hr0 antibody against Rh high-frequency antigen was suspected to be caused by multiple pregnancies which passes through the placental barrier and enable fetus to obtain anti Hr0 antibody, leading to HDFN, with genetic testing result as RH RHCE* Ce/RHCE* Ce. 【Conclusion】 In-depth research on the formation mechanism of Rh D-- in parturient should be conducted to provide clinical value for HDFN blood exchange treatment and blood transfusion in special blood group population.

3.
Chinese Journal of Analytical Chemistry ; (12): 835-841, 2016.
Article Dans Chinois | WPRIM | ID: wpr-494385

Résumé

Graphene oxide (GO) modified stationary phase for open tubular capillary (3 m × 25 μm i. d. ) of liquid chromatography ( OT-CLC) was fabricated by coating GO sheets onto poly ( vinylbenzyl chloride-divinylbenzene) porous composite layer via covalent coupling, which was prepared by in-situ polymerization. Scanning electron microscopy ( SEM), Raman spectroscopy and transmission electron microscopy ( TEM) were used to characterize the structure of the stationary phase. The results demonstrated that poly(vinylbenzyl chloride-divinylbenzene) porous composite layer had decentralized globular structure, and the GO sheets covered on the porous layer homogenously. The phase ratio and sample capacity were greatly improved due to the spherical polymer layer and the coverage of GO. Thus, alkyl benzenes, neutral polycyclic aromatic hydrocarbons, acidic and basic compounds could be well separated by using acetonitrile-water as eluent, while four nucleobases were completely separated by using acetonitrile-0. 02 mol/ L ammonium acetate as mobile phase. The run-to-run, day-to-day, and column-to-column reproducibilities were evaluated by calculating the relative standard deviations (RSDs, n =6) of the retention time of o-phenylenediamine, aniline and 2, 4, 6-trifluoroaniline, respectively. These RSD values were all in the range of 0. 3% -2. 0% .

SÉLECTION CITATIONS
Détails de la recherche