Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
Ajouter des filtres








Gamme d'année
1.
Chinese Journal of Hematology ; (12): 395-400, 2023.
Article Dans Chinois | WPRIM | ID: wpr-984635

Résumé

Objective: To compare the predictive efficacy of the two thrombosis risk assessment scores (Padua and IMPEDE scores) in venous thromboembolism (VTE) within 6 months in patients with newly diagnosed multiple myeloma (NDMM) in China. Methods: This study reviewed the clinical data of 421 patients with NDMM hospitalized in Beijing Jishuitan Hospital from April 2014 to February 2022. The sensitivity, specificity, accuracy, and Youden index of the two scores were calculated to quantify the thrombus risk assessment of VTE by the Padua and IMPEDE scores. The receiver operating characteristics curves of the two evaluation scores were drawn. Results: The incidence of VTE was 14.73%. The sensitivity, specificity, accuracy, and Youden index of the Padua score were 100%, 0%, 14.7%, and 0% and that of the IMPEDE score was 79%, 44%, 49.2%, and 23%, respectively. The areas under the curve of Padua and IMPEDE risk assessment scores were 0.591 and 0.722, respectively. Conclusion: IMPEDE score is suitable for predicting VTE within 6 months in patients with NDMM.


Sujets)
Humains , Thromboembolisme veineux/étiologie , Myélome multiple/diagnostic , Appréciation des risques , Facteurs de risque , Courbe ROC , Études rétrospectives
2.
Shanghai Journal of Preventive Medicine ; (12): 102-2021.
Article Dans Chinois | WPRIM | ID: wpr-875943

Résumé

Objective In 2019, Laboratory of Shanghai Chongming Center for Disease Control and Prevention participated in national assessment of individual dose monitoring capability. By analyzing the results, this report summarizes the experience and shortcomings that will help improve the individual dose monitoring capability of the laboratory. Methods According to the requirements of the national assessment scheme for individual dose monitoring capacity in 2019, the assessment process and results were sorted out and analyzed one by one. Results The single group performance deviations(Pi values)between the measured values and references of the five groups were -0.04, -0.07, -0.05, -0.04 and -0.06, respectively. The overall bias(B value)of all groups was 0.003. According to the judgment standards, both the single group performance and overall performance were all qualified. Conclusion The individual dose monitoring system of the laboratory meets the requirements of the relevant national standards. The individual dose monitoring capability can be further improved by strengthening the quality control of the relevant procedures of the assessment.

SÉLECTION CITATIONS
Détails de la recherche