Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtre
Ajouter des filtres








Gamme d'année
1.
Chinese Journal of Ultrasonography ; (12): 724-729, 2022.
Article Dans Chinois | WPRIM | ID: wpr-956648

Résumé

Objective:To investigate the normal parameter values of transvaginal E-Cervix cervical elastography of primipara and explore the correlation between E-Cervix parameters and gestational age.Methods:A total of 301 primiparas underwent E-Cervix by transvaginal ultrasound in Henan Provincial People′s Hospital from March 2019 to January 2021, they were divided into 6 groups according to generational weeks: group A (11-13 + 6W), group B (14-17 + 6W), group C (18-21 + 6W), group D (22-25 + 6W), group E (26-29 + 6W), group F (30-33 + 6W). Real-time E-Cervix parameters were obtained, including elasticity contrast index (ECI), hardness ratio (HR), internal ostium (IOS), and external ostium (EOS), strain ratio of the internal and external cervical ostium (IOS/EOS), and the correlations between E-Cervix parameters and the gestational week were analyzed. Results:The normal reference ranges of parameters ECI, IOS, EOS, HR and IOS/EOS were obtained, their 95% reference values in groups A to F were as follows: ECI (1.84-3.38, 2.13-4.50, 2.25-4.12, 2.06-3.96, 2.04-5.15, 2.36-5.53), HR (85.85%-88.72%, 77.31%-80.92%, 74.41%-78.50%, 71.13%-74.35%, 64.49%-68.56%, 63.57%-68.23%), IOS (0.12-0.21, 0.14-0.34, 0.14-0.31, 0.19-0.40, 0.19-0.56, 0.21-0.49), EOS (0.12-0.30, 0.14-0.34, 0.16-0.41, 0.20-0.39, 0.22-0.58, 0.22-0.54), IOS/EOS (0.55-1.12, 0.52-1.45, 0.56-1.26, 0.54-1.38, 0.54-1.52, 0.65-1.46). The differences of ECI, HR, IOS and EOS in different groups were statistically significant (all P<0.05). Spearman correlation analysis results showed that ECI, IOS, and EOS were positively correlated with gestational week( rs=0.524, 0.689, 0.609; all P<0.01). HR was negatively correlated with gestational week ( rs=-0.755, P<0.01). The regression equations of ECI, HR, IOS and EOS were Y=0.06X+ 52.214, Y=99.25-1.07X, Y=8.63E-3X+ 0.05, Y=7.94E-3X+ 0.1, respectively. Conclusions:The normal parameters values of E-TVES are summarized.It provides effective support in data for cervical evaluation in the preterm prediction and success of labor induction.

2.
Chinese Journal of Integrated Traditional and Western Medicine in Intensive and Critical Care ; (6): 147-150, 2017.
Article Dans Chinois | WPRIM | ID: wpr-505818

Résumé

Objective To detect the expression of matrix metalloproteinase-9 (MMP-9) gene in peripheral blood of patients with oral paraquat (PQ) poisoning and evaluate its predictive value for their prognosis.Methods Thirty-seven cases of oral PQ poisoning admitted to Linyi People's Hospital from January 2013 to June 2014 were enrolled,and they were divided into survival group (26 cases) and death group (11 cases) according to the survival sitnation in 28 days after poisoning;a healthy control group included 10 healthy people selected in the same period.The peripheral blood 3 mL was collected from each PQ patient on the 1st and 3rd day after admission,and in the healthy control group,3 mL peripheral venous blood was obtained under fast on the day for physical examination.The MMP-9 gene expression of peripheral blood mononuclear cells (PBMCs) was detected by reverse transcription-polymerase chain reaction (RT-PCR) methods;the serum MMP-9 concentration was determined by using enzyme-linked immunosorbent assay (ELISA);the serum PQ level was detected by high performance liquid chromatography (HPLC),and the amount of poison orally taken was recorded.The correlations between PQ amount orally taken,serum PQ level and MMP-9 expression were analyzed by Spearman correlation analysis.A receiver operating characteristic (ROC) curve was drawn to evaluate the predictive value of peripheral blood MMP-9 level for the 28-day prognosis of PQ poisoning patients.Results After admission the 1 day serum PQ level was (2.60 ± 1.29) mg/L,and the amount of poison taken was 50.0 (7.5,60.0) mL in the 37 patients with oral PQ poisoning.The MMP-9 gene expression level in PBMCs and serum MMP-9 protein level of both PQ poisoning groups were significantly higher than those of healthy control group,and the levels were gradually increased with the extension of poisoning time;the degrees of elevation in death group were more significant [the PBMCs' MMP-9 gene expression (A value):2.84± 1.16 vs.0.95 ± 0.23 on the 1st poisoning day,4.22± 1.75 vs.1.29 ±0.30 on the 3rd poisoning day;serum MMP-9 concentration (μg/L):2791.48± 1 230.88 vs.807.81±279.86 on the 1st poisoning day,4384.21 ± 1 781.97 vs.1 131.14±291.76 on the 3rd poisoning day,all P < 0.05].Correlation analysis showed:there were significant positive correlations of oral PQ amount,serum PQ concentration to the MMP-9 gene expression in PBMCs and serum MMP-9 protein concentration in patients with oral PQ poisoning (all P =0.000).ROC curve analysis showed:the MMP-9 gene expression in PBMCs on the 1st day and the serum MMP-9 content on the 3rd day after admission had predictive value for 28-day prognosis in patients with oral PQ poisoning,and the ROC areas under the curve (AUC) was 0.820 and 0.776 respectively.When the cutoff value of MMP-9 gene expression level on the 1st day after admission was 0.90,the predictive sensitivity and specificity were 80.00% and 63.64% respectively;when the cutoff value of serum MMP-9 protein content on the 3rd day after admission was 904.36 μg/L,the predictive sensitivity and specificity were 80.00% and 72.73% respectively.Conclusion Oral PQ poisoning can lead to the MMP-9 gene expression in PBMCs and elevation of serum MMP-9 protein level in the body,and the MMP-9 gene expression has predictive value for the prognosis of patients with oral PQ poisoning.

3.
Chinese Journal of Ultrasonography ; (12): 1057-1061, 2017.
Article Dans Chinois | WPRIM | ID: wpr-707611

Résumé

Objective To investigate the application value of three-dimensional shear wave elastography( 3D-SWE) in diagnosis of malignant and benign breast masses . Methods Sixty-seven patients with total 96 masses diagnosed by ultrasound and verified with surgical pathological analysis were selected . The masses were divided into benign group ( 54 masses ) and malignant group ( 42 masses ) . The quantitative diagnosis was performed using two-dimensional shear wave elastography ( 2D-SWE) and 3D-SWE to evaluate the hardness of the masses . Receiver operating characteristic ( ROC ) curves of 2D-SWE and 3D-SWE were drawn to calculate the sensibility and specificity in diagnosis of breast masses . The qualitative diagnosis was performed according to the elastic color image classification to classify the elastic images of the lesions into type Ⅰ - Ⅳ . Results The quantitative diagnosis:① There were significant differences in Emean ,Emax and SD on planes of 2D-SWE and three orthogonal planes of 3D-SWE between the two groups ( P <0 .05) ;② There was no significant difference in Emean ,Emax and SD of two groups between 2D-SWE and 3D-SWE ( P > 0 .05) ;③ Emean ,Emax and SD on planes of 2D-SWE and three orthogonal planes of 3D- SWE both exhibited high diagnostic performance . However , there was no significant difference in Emean ,Emax and SD between 2D-SWE and 3D-SWE ( P >0 .05) . The qualitative diagnosis of elastic color mode:type Ⅰ and type Ⅱ account for most planes of 2D-SWE and three orthogonal planes of 3D-SWE in benign masses ,while type Ⅲ and type Ⅳ account for most in malignant masses . Among the malignant group ,type Ⅲ on the 3D-SWE coronal planes was significantly more than other three types ( P < 0 .05) .Conclusions For quantitative diagnosis ,2D-SWE and 3D-SWE are both beneficial to differentiate benign from malignant masses ,but there is no difference in diagnostic efficacy ;for qualitative diagnosis ,3D-SWE can provide more diagnostic information than 2D-SWE ,especially on the coronal planes of 3D-SWE .

SÉLECTION CITATIONS
Détails de la recherche