Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 4 de 4
Filtre
Ajouter des filtres








Gamme d'année
1.
Chinese Journal of Medical Instrumentation ; (6): 91-95, 2022.
Article Dans Chinois | WPRIM | ID: wpr-928865

Résumé

To provide accurate information for registration and safety evaluation of surgical robot, the pose repeatability measurement method was proposed. According to the terminal instrument of the master-slave surgical robot (such as high-frequency electric knife, ultrasonic knife), a suitable target ball fixture was designed. The node data at 10%, 50% and 100% rated speed were measured respectively. Through data analysis, the pose repeatability property of the tested samples at different speeds was obtained. It has high applicability and repeatability, and can meet the requirements of data traceability and registration testing.


Sujets)
Conception d'appareillage , Lasers , Interventions chirurgicales robotisées , Robotique , Chirurgie assistée par ordinateur
2.
Chinese Journal of Emergency Medicine ; (12): 1290-1295, 2017.
Article Dans Chinois | WPRIM | ID: wpr-669052

Résumé

Objective To explore the clinical significance of B7 family homology factor-3 (B7-H3),an expression membrane type of myeloid-derived suppressor cell (MDSC),in patients with acute pancreatitis (AP).Methods A total of 63 patients with AP initially treated in the Emergency Department at the First Affiliated Hospital of Soochow University from January,2014 to December,2015 were selected.Of them,25 suffered from mild AP (MAP),20 had moderate AP (MSAP) and 18 had severe AP (SAP).Another 20 healthy subjects with matching age and gender served as the control group.All patients with AP conformed to the diagnostic criteria of Guidelines or Diagnosis and Treatment of Acute Pancreatitis set in 2013 in China.Patients with other underlying diseases that might influence the clinical outcomes were excluded,including those with tumors,autoimmune diseases,viral infections,trauma and other disorders.A flowcytometer was used to detect the expression rate of MDSC in peripheral venous blood and the expression of B7-H3 on MDSC membrane.The continuous monitoring was carried out for 24 h,48 h and 72 h in patients with AP.Results Compared with healthy subjects,the MDSC cells in patient groups 24 hours after AP onset increased notably (P <0.01) especially the highest increase in the SAP group,followed by the MSAP group and the lowest in the MAP group.There were significant differences in pairwise comparisons (P < 0.05).From successive observation of each group,there was no significant difference in MDSC between the MAP group and the MSAP group 24 hours,48 hours and 72 hours after AP onset.However,MDSC reached its peak 48 hours after AP onset,but it declined 72 hours after AP onset in the SAP group (P < 0.05).B7-H3 expressed significantly 24 hours after AP onset,but there was no expression of B7-H3 in the healthy group.Meanwhile,B7-H3 was expressed most highly in the SAP group,followed by the MSAP group and lowest in the MAP group.There were significant differences in expression of B7-H3 found in pairwise comparisons (P < 0.05).The successive observation showed that there was no significant difference in B7-H3 expression between the MAP group and the MSAP group 24 hours,48 hours and 72 hours after AP onset.However,there was a trend of increase in B7-H3 expression as time prolonged found among 24 hours,48 hours and 72 hours after AP onset in the SAP group (P < 0.05).Conclusions The expressions of MDSC and B7-H3 were high in AP,and there were significant differences in both expressions among MAP,MSAP and SAP groups.These phenomena offer clues in further understanding about the immunological disorders during AP giving better guidelines for clinical practice.

3.
Chinese Journal of Medical Instrumentation ; (6): 216-218, 2015.
Article Dans Chinois | WPRIM | ID: wpr-265660

Résumé

This article presents several common problems.of medical injection pump through one case of ESD troubleshooting. Expounds the causes of the problem and provides solutions.


Sujets)
Équipement et fournitures , Injections , Électricité statique
4.
Chinese Medical Equipment Journal ; (6)1989.
Article Dans Chinois | WPRIM | ID: wpr-593564

Résumé

Objective To design a new type of field operation instrument for easy to spread a rescue surgery rapidly in field first -aid at the present stage. Methods The traditional field operation instrument set is innovated in its composition, structure and function. The packing instrument procedure can be omitted. The new field operation instrument set is made of four different operation instrument boxes, two of which can be put into a standard field medical case. Results It is designed to be convenient to have a rescue surgery rapidly and to be washed, sterilized, conveyed and kept in aseptic storage. Conclusion The new field operation instrument case has such advantages as compactness, reasonable allocation and function completed, so it can be used easily.

SÉLECTION CITATIONS
Détails de la recherche