Chinese Journal of Medical Instrumentation ; (6): 349-354, 2021.
Article Dans Chinois | WPRIM | ID: wpr-880482

Résumé

OBJECTIVE@#Whether the developed new type of radiotherapy auxiliary fixation device compatible with the head and neck joint coil can improve the quality of magnetic resonance images in radiotherapy and verify whether it can be applied to clinical treatment.@*METHODS@#The clinical trial selected patients with brain metastases and nasopharyngeal cancer patients, using thermoplastic film and head and shoulder molds for posture fixation, and treatment on the ELekta Versa accelerator. SPSS 20.0 statistical software was used to analyze the data. The measurement data were expressed by @*RESULTS@#Considering the influence of the outer contour of the device, the target dose meets the clinical requirements. The setting error is less than 2 mm in the three translation directions, and the rotation error is less than 2@*CONCLUSIONS@#There is no statistical difference between the treatment results of patients using the new type of fixation device and the conventional method. The target area threatens the organ dose, and the positioning error meets the treatment requirements.


Sujets)
Humains , Imagerie par résonance magnétique , Spectroscopie par résonance magnétique , Tumeurs du rhinopharynx , Cou , Posture
2.
Chinese Journal of Medical Instrumentation ; (6): 326-329, 2019.
Article Dans Chinois | WPRIM | ID: wpr-772494

Résumé

MRI simulation images quality of head and neck coil scanning is better than that of radiotherapy surface coil, but currently the head and neck coil is not compatible with radiotherapy positioning devices. In this paper, a new fixation device is developed based on computer reverse engineering technology, which can be used in combination with head and neck coil. This article focuses on discussing the feasibility of the new device in radiotherapy. The obtained ACR phantom and Cat phantom 504 images were used to analyze MR and CT images quality assurance indicators. The dose attenuation of 6 MV photons was measured using the ionization chamber. The results showed each index met the clinical application requirements of intracranial tumor radiotherapy, thereby it can be used in intracranial tumor radiotherapy.


Sujets)
Humains , Études de faisabilité , Tumeurs de la tête et du cou , Imagerie diagnostique , Imagerie par résonance magnétique , Fantômes en imagerie , Planification de radiothérapie assistée par ordinateur