Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtre
Ajouter des filtres








Gamme d'année
1.
Chinese Journal of Medical Education Research ; (12): 1681-1686, 2022.
Article Dans Chinois | WPRIM | ID: wpr-991220

Résumé

Objective:To solve the difficult problem of experimental teaching of MRI equipment by independently designing a virtual simulation teaching system for performance testing of medical magnetic resonance imaging (MRI) equipment.Methods:A total of 202 students of Batch 2016 majoring in 4-year medical imaging technology and 5-year medical imaging of Binzhou Medical University. According to the teaching requirements of MRI equipment in Medical Imaging Equipment Science, a 3D experimental simulation model and experimental scenes were established based on Unity3D engine by using Unity3D, 3D Studio Max, Maya and Visual Studio technology to design experimental learning content and assessment content, develop the teaching system software and perform Web-based online learning. Then, the satisfaction survey on experimental learning was conducted, the statistics of the experimental results of the teaching system on the national virtual simulation experiment teaching platform was collected and the learning effects were evaluated in multiple dimensions. Results:The virtual simulation teaching system was a comprehensive experiment with 12 knowledge points, 12 experimental items and a total of 81 interactive contents and steps. The overall satisfaction rate of 202 students in our school was 96.82%(2 347/2 424). Among the 499 subjects who participated in the learning of the teaching system on the national virtual simulation experiment teaching platform and submitted the experimental report, the average score of the experiment was 78.07 points (the full score of online learning assessment was 90 points), and the overall passing rate was 96.79%(483/499). The average learning time of the 18 students who got 90 points was 54 min.Conclusion:This virtual simulation teaching system possesses comprehensive experimental contents with high fidelity of experimental scenes and strong interactivity of experimental operation, prospecting great learning effects and promotion value.

2.
Chinese Journal of General Practitioners ; (6): 553-557, 2019.
Article Dans Chinois | WPRIM | ID: wpr-755967

Résumé

Objective To evaluate the accuracy of measurements of atherosclerotic middle cerebral artery (MCA) stenosis with 3.0 T high-resolution magnetic resonance imaging (HR-MRI).Methods Forty patients with symptomatic atherosclerotic stenosis of middle cerebral artery (MCA) confirmed by digital subtraction angiography (DSA) in the Affiliated Hospital of Binzhou Medical College from September 2017 to May 2018 were enrolled in the study.Patients were scanned by HR-MRI sequence (including T1WI,T2WI,PDWI).The MCA M1 stenosis rate on HR-MR images was assessed by warfarin-aspirin symptomatic intracranial artery disease (WASID) method and area measurement algorithm,respectively,and based on the stenosis rate the degree of stenosis (semi-quantitative measurement) was determined.The accuracy of the two measurement methods was evaluated with DSA results as the gold standard.Results The HR-MRI images showed the structure of the vessel wall clearly in 30 patients meeting the measurement requirements.The inner edge of the vessel was clearly distinguishable and smooth,showing eccentric stenosis.The stenosis rate of MCA measured by DSA,WASID method and area measurement algorithm were (82± 17)%,(70± 12)%,(81 ± 16)%,respectively (P>0.05).The result of area measurement algorithm was better correlated with DSA (r=0.893);and the coincidence of the stenosis degree rate of two measurement method was 90%(27/30).Conclusion The area measurement algorithm based on the HS-MRI has high accuracy in measuring the degree of MCA stenosis,which is of high clinical application value.

3.
Journal of Practical Radiology ; (12): 1018-1020, 2014.
Article Dans Chinois | WPRIM | ID: wpr-452285

Résumé

Objective To evaluate the effect of non-linear blending function for dual-energy CT on image of pulmonary angiogra-phy.Methods 27 patients underwent dual energy CT pulmonary angiography(CTPA).Data obtained with 100 kVp,140kVp,and non-linear blending were divided into group A,B,and C respectively.CT value of emboli were measured.Corresponding signal to noise ratio(SNR )and contrast to noise ratio(CNR)were calculated.One-way Anova analysis and Friedman test were used to ana-lyze statistical significance among these values.Results On quantitative analysis of 27 patients,there was no statistical difference for CT value of CTPA among the three groups(P >0.05).For the noise,CNR and SNR,there were statistically significant among the three groups(P <0.05).Conclusion The non-linear blending function has certain advantages in improved image signal-to-noise ratio and it can be used in CT pulmonary angiography examination for patients suspected pulmonary embolism clinically .

SÉLECTION CITATIONS
Détails de la recherche