Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 5 de 5
Filtre
Ajouter des filtres








Gamme d'année
1.
Chinese Journal of Tissue Engineering Research ; (53): 2133-2139, 2019.
Article Dans Chinois | WPRIM | ID: wpr-743869

Résumé

BACKGROUND: There is no report on the treatment of suppurative discitis with posterior microendoscopic discectomy, antibiotic artificial bone implantation and one-stage percutaneous pedicle screw fixation. OBJECTIVE: To evaluate the clinical effectiveness of posterior microendoscopic debridement, antibiotic artificial bone implantation and one-stage percutaneous pedicle screw fixation for pyogenic spondylodiscitis. METHODS: Thirty-one patients with suppurative discitis admitted at the Department of Spinal Surgery, the First Affiliated Hospital of Guangzhou Medical University from January 2014 to December 2017, including 17 males and 14 females, aged 28-78 years, were included. All the patients underwent posterior microendoscopic lesion clearance and antibiotic artificial bone grafting and one-stage percutaneous pedicle screw fixation. The erythrocyte sedimentation rate and C-reactive protein levels were detected at postoperative follow-up. The Visual Analog Scale and the Japanese Orthopaedic Association scores were used for detection. RESULTS AND CONCLUSION: (1) All the surgical operations of the 31 patients were successfully completed and all patients had immediate relief of low back pain and lower extremity radiation pain. They were able to move ground wearing a waistband at 1-4 days postoperatively. (2) Thirty-one patients were followed up for 9-18 months. All patients had a significant decrease in C-reactive protein and erythrocyte sedimentation rate at 1 week after surgery, and C-reactive protein and erythrocyte sedimentation rate were in the normal range at 1, 3, and 6 months postoperatively. (3) The Visual Analog Scale scores of all patients at 1 week of follow-up were significantly lower than those before surgery (P < 0.05) , and the Japanese Orthopaedic Association scores were significantly higher than those before surgery (P < 0.05) . (4) In the follow-up examination of CT and MRI, there was no recurrence, pseudoarticular formation or internal fixation loosening. (5) These results suggest that posterior microendoscopic discectomy, antibiotic artificial bone implantation combined with one-stage percutaneous pedicle screw fixation for treating suppurative discitis can result in little trauma, few bleeding and rapid pain relief, and patients can move to the ground early. The operation method has a good clinical effect.

2.
Chongqing Medicine ; (36): 2525-2528, 2017.
Article Dans Chinois | WPRIM | ID: wpr-620324

Résumé

Objective To evaluate the accuracy and safety of pedicle-scope assisted pedicle screw fixation and percutaneous pedicle screw fixation for treating lumbar degenerative disease(LDD).Methods Thirty cases of LDD treated by mini-invasive transforaminal lumbar interbody fusion(TLIF) under microscope plus percutaneous pedicle screw fixation with fluoroscopy or pedicle-scope of lumbar spine from December 2013 to September 2015 were selected and divide into the percutaneous group and pediclescope group,15 cases in each group.The operative duration,intraoperative blood loss volume,hospital stay and complications were compared between the two groups.The clinical effects were assessed with visual analogue scale(VAS) and Oswestry disability index(ODI).The plain radiography,dynamic radiology and lumbar magnetic resonance imaging(MRI) and computed tomography (CT) were re-examined after operation for assessing the screw location and fusion rate.Results Eighty-four screws were placed in the percutaneous group and 70 screws in the pedicle-scope group.In the percutaneous group and pedicle-scope group,the mean intraoperative blood loss volume,mean operative duration,average times of C-arm fluoroscopy,mean length of hospital stay,mean time of off-bed and complication occurrence rate were measured,and the differences were not statistically significant (P> 0.05).In 6-month follow up,the VAS score and ODI score in the two groups were significantly improved compared with before operation(P<0.01);the VAS score and ODI score were(2.50 ± 1.30) and (50.00-±-3.50) in pediclescope group,(3.00± 1.50) and (58.00 ±4.50) in percutaneous group,respectivehy,and the differences were statistically significant(P<0.05);the improvement rates of clinical symptoms in the percutaneous group and pedicle-scope group were 73.33 % and 80.00 % respectively.The imaging reexamination showed that the placed screw location was good and lesion segment fusion was good without screw loosening.The location of 3 screws in the percutaneous group was deviated and adjusted by the second operation.Conclusion The accuracy and safety of pedicle-scope assisted screw placing for treating LDD are higher than those of conventional percutaneous pedicle screw fixation,moreover the operative time is shorter with less intraoperative bleeding.

3.
Modern Clinical Nursing ; (6): 55-58, 2016.
Article Dans Chinois | WPRIM | ID: wpr-485639

Résumé

Objective To explore the effect of one-piece shoulder pillow on patients suffering from shoulder pain and skin erubescence during gynecological laparoscopy with lithotomy position and trendelenburg position. Methods Two hundred and six patients who underwent gynecological laparoscopic operation were divided into control and experiment groups according to cardinal or even number of registration. The patients in both groups were set in lithotomy position and trendelenburg position during the operation, with the difference in the use of a common shoulder pillow for support in the control group but no use in the experiment one. On-position time and incidence rate of shoulder pain and skin erubescence were compared between two groups. Result The sholder pain and skin erubescence were less than those of control group (P < 0.05). Conclusion Use of one-piece shoulder pillow can reduce the incidence rates of shoulder pain and skin erubescence after gynecological laparoscopic operation with lithotomy position and trendelenburg position.

4.
Chinese Journal of Tissue Engineering Research ; (53): 1309-1314, 2016.
Article Dans Chinois | WPRIM | ID: wpr-484846

Résumé

BACKGROUND:The existing bone grafting apparatus are al long tubular-shape, antegrade bone grafting; however, the bone grains within the tube were difficult to put through, along with large bone loss. OBJECTIVE:To design a new concept of minimaly invasive bone grafting apparatus, so as to achieve the minimaly invasive bone grafting in vertebral body and intervertebral space. METHODS: On Solidworks 2012 software platform, the 3D three-dimensional solid modeling technology was employed to design a new concept of gun-shape bone grafting device with the characteristics of headend reversely placing at the grafting position and antegrade pushout, against the problems such as antegrade bone grafting, long bone grafting path and difficulty in bone grafting existing in precious percutaneous or/and transpedicular bone graft apparatus. The virtual assembly and simulative bone grafting surgery were performed with the bone grafting apparatus for observation of the instrument matching degree and grafting surgical procedures. RESULTS AND CONCLUSION: A set of minimaly invasive gun-shape bone grafting apparatus was successfuly designed; its length was 20 cm in total; the length of the front semi-closed bone tube was 2.5 cm. There are two kinds of diameter specifications: inner diameter of 3.5 mm/outer diameter of 4 mm, and inner diameter of 5 mm/outer diameter of 6 mm. Virtual assembly revealed that the grafting apparatus were wel matched. Stimulative surgery displayed that the bone grain loading and launch were simple. The gun-shape bone grafting device is reasonable in design, avoiding pushing too long distance, bone pushing difficulties, bone loss and other problems in previous tubular bone grafting apparatus. Percutaneous, endoscopic vertebrae or intervertebral space minimaly invasive bone grafting can be performed with this apparatus.

5.
Chinese Journal of Tissue Engineering Research ; (53): 3081-3084, 2010.
Article Dans Chinois | WPRIM | ID: wpr-402487

Résumé

BACKGROUND: Magnetic resonance imaging(MRI)is considered safe for diagnosis of meniscus injury,having accuracy as high as 80% to 100%.However,it is found that there are some false positive and false negative in the clinic.OBJECTIVE: Through assessment of menisci injuries of the knee using magnetic resonance imaging and arthroscopy,to investigate MRI manifestation in different types of meniscal injuries.METHODS: A study from January 2003 to December 2008 was performed in 212 patients with knee injury undergoing preoperative MRI.Radiograph was read by physicians who had a senior professional title from radiology and orthopaedics departments,and meniscus damage and damage morphology were predicted.Arthroscopy was conducted by chief physician.Meniscus damage during surgery was considered as gold standards.The accuracy of them was compared.The statistics of accuracy of MRI diagnosis was gathered.RESULTS AND CONCLUSION: Totally 212 patients and 230 knees were included,and a total of 215 knees of meniscus injury were described by MRI diagnosis and 213 knees of meniscus injury were proven by arthroscopy.The sensitivity,specificity and accuracy of MRI diagnosis of meniscus injury respectively were 93.5%,64.7%,93.0%.It is found that the sensitivity of MRI diagnosis of bucket-handle damage is high.MRI is easy to miss diagnosis in a light meniscus posterior horn tear,and resuts are more false positive in lateral meniscus injury.It needs arthroscope operation or further surgery in some condition such as gradeⅢ type injury,meniscus displacement after injury and articular capsule separation,which indicates instable meniscus.

SÉLECTION CITATIONS
Détails de la recherche