Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 7 de 7
Filtre
1.
Journal of Biomedical Engineering ; (6): 1246-1249, 2009.
Article Dans Chinois | WPRIM | ID: wpr-244651

Résumé

This paper introduces the hardware and software of a biomechanical robot-based testing device. The bottom control orders, posture and torque data transmission, and the control algorithms are integrated in a unified visual control platform by Visual C+ +, with easy control and management. By using hybrid force-displacement control method to load the human spine, we can test the organizational structure and the force state of the FSU (Functional spinal unit) well, which overcomes the shortcomings due to the separation of the force and displacement measurement, thus greatly improves the measurement accuracy. Also it is esay to identify the spinal degeneration and the load-bearing impact on the organizational structure of the FSU after various types of surgery.


Sujets)
Humains , Algorithmes , Phénomènes biomécaniques , Conception d'appareillage , Articulations , Physiologie , Robotique , Méthodes , Logiciel , Rachis , Physiologie
2.
Journal of Biomedical Engineering ; (6): 244-252, 2009.
Article Dans Chinois | WPRIM | ID: wpr-280223

Résumé

Multi-modal medical image fusion has important value in clinical diagnosis and treatment. In this paper, the multi-resolution analysis of Daubechies 9/7 Biorthogonal Wavelet Transform is introduced for anatomical and functional image fusion, then a new fusion algorithm with the combination of local standard deviation and energy as texture measurement is presented. At last, a set of quantitative evaluation criteria is given. Experiments show that both anatomical and metabolism information can be obtained effectively, and both the edge and texture features can be reserved successfully. The presented algorithm is more effective than the traditional algorithms.


Sujets)
Humains , Algorithmes , Intelligence artificielle , Imagerie diagnostique , Méthodes , Amélioration d'image , Méthodes , Interprétation d'images assistée par ordinateur , Méthodes , Traitement d'image par ordinateur , Méthodes , Reconnaissance automatique des formes , Méthodes , Tomographie par émission de positons , Méthodes , Tomodensitométrie , Méthodes
3.
Journal of Biomedical Engineering ; (6): 1178-1183, 2008.
Article Dans Chinois | WPRIM | ID: wpr-318189

Résumé

A Fast Multi-resolution Volume Rendering Method (FMVRM) based on wavelet and Shear-Warp is herein proposed. In this method, the medical volume data is compressed using wavelet transformation first. Then based on the set resolution, the medical volume data is decompressed guided by Opacity transfer function (OTF). Finally, the 3D medical image is reconstructed on the basis of Shear-Warp using Block-based run length encoded (BRLE) data structure, in which, the aliasing artifacts resulting from under-sampling in Shear-Warp is avoided by the pre-integrated volume rendering technology. Experiments demonstrate the good performance of the proposed method.


Sujets)
Humains , Algorithmes , Artéfacts , Compression de données , Méthodes , Imagerie tridimensionnelle , Méthodes
4.
Journal of Biomedical Engineering ; (6): 524-530, 2008.
Article Dans Chinois | WPRIM | ID: wpr-291198

Résumé

In order to improve the effect and efficiency of the reconstructed image after hybrid volume rendering of different kinds of volume data from medical sequential slices or polygonal models, we propose a hybrid volume rendering method based on Shear-Warp with economical hardware. First, the hybrid volume data are pre-processed by Z-Buffer method and RLE (Run-Length Encoded) data structure. Then, during the process of compositing intermediate image, a resampling method based on the dual-interpolation and the intermediate slice interpolation methods is used to improve the efficiency and the effect. Finally, the reconstructed image is rendered by the texture-mapping technology of OpenGL. Experiments demonstrate the good performance of the proposed method.


Sujets)
Algorithmes , Infographie , Traitement d'image par ordinateur , Méthodes , Illustration médicale , Modèles anatomiques , Fantômes en imagerie
5.
Journal of Biomedical Engineering ; (6): 27-29, 2008.
Article Dans Chinois | WPRIM | ID: wpr-230663

Résumé

Limited by the imaging principle of whole body bone SPECT image, the gray value of bladder area is quite high, which affects the image's brightness, contrast and readability. In the meantime, the similarity between bladder area and focus makes it difficult for some images to be segmented automatically. In this paper, an improved Snake model, GVF Snake, is adopted to automatically segment bladder area, preparing for further processing of whole body bone SPECT images.


Sujets)
Humains , Algorithmes , Os et tissu osseux , Imagerie diagnostique , Traitement d'image par ordinateur , Modèles anatomiques , Tomographie par émission monophotonique , Méthodes , Vessie urinaire
6.
Journal of Biomedical Engineering ; (6): 1050-1053, 2007.
Article Dans Chinois | WPRIM | ID: wpr-346013

Résumé

In this paper, BP neural network is used to segment whole body bone SPECT image so that the lesion area can be recognized automatically. For the uncertain characteristics of SPECT images, it is hard to achieve good segmentation result if only the BP neural network is employed. Therefore, the segmentation process is divided into three steps: first, the optimal gray threshold segmentation method is employed for preprocessing, then BP neural network is used to roughly identify the lesions, and finally template match method and symmetry-removing program are adopted to delete the wrongly recognized areas.


Sujets)
Humains , Algorithmes , Os et tissu osseux , Imagerie diagnostique , Interprétation d'images assistée par ordinateur , Méthodes , , Reconnaissance automatique des formes , Méthodes , Tomographie par émission monophotonique , Imagerie du corps entier
7.
Journal of Biomedical Engineering ; (6): 1241-1259, 2007.
Article Dans Chinois | WPRIM | ID: wpr-230710

Résumé

Based on the characteristic of the PET-CT multimodal image series, a novel image registration and fusion method is proposed, in which the cubic spline interpolation method is applied to realize the interpolation of PET-CT image series, then registration is carried out by using mutual information algorithm and finally the improved principal component analysis method is used for the fusion of PET-CT multimodal images to enhance the visual effect of PET image, thus satisfied registration and fusion results are obtained. The cubic spline interpolation method is used for reconstruction to restore the missed information between image slices, which can compensate for the shortage of previous registration methods, improve the accuracy of the registration, and make the fused multimodal images more similar to the real image. Finally, the cubic spline interpolation method has been successfully applied in developing 3D-CRT (3D Conformal Radiation Therapy) system.


Sujets)
Humains , Algorithmes , Intelligence artificielle , Imagerie diagnostique , Méthodes , Amélioration d'image , Méthodes , Interprétation d'images assistée par ordinateur , Méthodes , Imagerie tridimensionnelle , Méthodes , Reconnaissance automatique des formes , Méthodes , Tomographie par émission de positons , Méthodes , Planification de radiothérapie assistée par ordinateur , Méthodes , Tomodensitométrie , Méthodes
SÉLECTION CITATIONS
Détails de la recherche