1.
Military Medical Sciences ; (12): 714-718, 2017.
Article Dans Chinois | WPRIM | ID: wpr-665576

Résumé

Objective To improve vibration resistance of conventional blood transportation kits and mitigate hemolysis during transportation.Methods The structure of a blood transportation kit was modified.We installed a suspension brac-kets within the kit,added buffer material between the brackets,and tested the vibration-suppressing effect compared with the conventional blood transportation kit.Results Rubber and plastic materials between brackets were added,and double membrane suspension brackets were installed.After 4 and 6 min of vibration,free hemoglobin(FHb)[(1559.7 ±1038.5) and(1886.2 ±1023.8)mg/L],lactic dehydrogenase levels[(135.3 ±67.7)and(195.7 ±123.6)U/L]and hemolysis rate[(0.35 ±0.34)%and(0.42 ±0.38)%]in the conventional transportation kit were significantly higher than in the vibration-suppressing kit.K+did not change significantly,and was comparable in both groups at each time point.After 4 and 6 min of vibration, FHb in the conventional transportation kit exceeded the standard.However, after 12 min of vibration,FHb[(560.1 ±342.3)mg/L]in the vibration-suppressing kit were within the standard range.No bacterial growth was detected in either group.Conclusion The vibration-suppressing kit under research shows a better 1986vibration-suppressing effect,which could improve blood support capability in case of emergency.

2.
Military Medical Sciences ; (12): 719-722, 2017.
Article Dans Chinois | WPRIM | ID: wpr-665575

Résumé

Objective To study the thermal insulation properties of vacuum insulated panel(VIP)used as materials for blood transportation kits.Methods A VIP transportation kit was taken as test group,and a conventional transportation kit was taken as control.Phase change cool storage materials of the same amount and 4℃water bags were put into both kits.A recordable electronic thermometer was used to record the temperature within the two kits,and free hemoglobin(FHb)and potassium ion concentration were measured at 0, 4, and 7 days after blood storage.Results The temperature in the conventional transportation kit increased faster after 36 h, and was significantly higher than in the VIP transportation kit until 60 h.Besides,the VIP transportation kit kept the temperature under 10℃ for(60.7 ±0.6)h, compared to (54.2 ±3.0)h in the conventional transportation kit.FHb concentration was significantly lower in the VIP transportation kit[(605.26 ±74.63)mg/L]than in the conventional transportation kit[(1327.60 ±187.41)mg/L]at day 7(d 7),so was the potassium ion concentration in the VIP transportation kit[(22.7 ±0.4)mmol/L]compared to[(24.6 ±0.6) mmol/L]in the transportation kit at d 7.Conclusion The VIP transportation kit keeps the temperature under 10℃ for a longer time,and the blood quality of preservation is better than that of the conventional transportation kit.Novel heat preservation material can improve health support ability,and is of great value and significance.

SÉLECTION CITATIONS
Détails de la recherche