Chinese Medical Equipment Journal ; (6): 5-11, 2017.
Article Dans Chinois | WPRIM | ID: wpr-662466

Résumé

Objective To relieve the influences of the respiratory motion on the liver contrast-enhance ultrasound (CEUS) image sequences,to enhance the quantitative analysis accuracy for liver CEUS and to put forward a correction strategy for the respiratory motion in liver CEUS sequences.Methods A principal component analysis (PCA) model of the respiratory motion in liver CEUS sequences was established with 18 cases of rabbit liver VX2 tumors,and a respiratory motion curve was generated based on the principal component with large data proportion,then the images with similar phases to the reference image were analyzed.Resnlts Correction made the mean structural similarity and mean correlation coefficient enhanced significantly to 0.57±0.11 and 0.78±0.11 respectively (P<0.001),while the average of deviation valve (DV) was decreased to 29.9±7.02 which only was one-third of the original value.Threshold setting could further improve the quality of the selected image sequence.Conchusion The proposed respiratory motion method proves its effectiveness for rabbit liver CEUS image sequences,and thus contributes to enhancing the differential diagnosis rate of benign and malignant liver tumors.

2.
Chinese Medical Equipment Journal ; (6): 5-11, 2017.
Article Dans Chinois | WPRIM | ID: wpr-660097

Résumé

Objective To relieve the influences of the respiratory motion on the liver contrast-enhance ultrasound (CEUS) image sequences,to enhance the quantitative analysis accuracy for liver CEUS and to put forward a correction strategy for the respiratory motion in liver CEUS sequences.Methods A principal component analysis (PCA) model of the respiratory motion in liver CEUS sequences was established with 18 cases of rabbit liver VX2 tumors,and a respiratory motion curve was generated based on the principal component with large data proportion,then the images with similar phases to the reference image were analyzed.Resnlts Correction made the mean structural similarity and mean correlation coefficient enhanced significantly to 0.57±0.11 and 0.78±0.11 respectively (P<0.001),while the average of deviation valve (DV) was decreased to 29.9±7.02 which only was one-third of the original value.Threshold setting could further improve the quality of the selected image sequence.Conchusion The proposed respiratory motion method proves its effectiveness for rabbit liver CEUS image sequences,and thus contributes to enhancing the differential diagnosis rate of benign and malignant liver tumors.

SÉLECTION CITATIONS
Détails de la recherche