Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
Ajouter des filtres








Gamme d'année
1.
Ann Card Anaesth ; 2018 Jan; 21(1): 88-91
Article | IMSEAR | ID: sea-185686

Résumé

Atrial fibrillation is the most common arrhythmia associated with significant mortality and morbidity secondary to thrombo-embolism. To prevent this thrombo-embolism oral anticoagulation therapy is the recommended treatment. In patients with contraindications to oral anticoagulation therapy, percutaneous left atrial appendage occlusion device is indicated. TEE is essential to guide in all the stages of LAA device deployment. Right from pre-procedure screening, to guiding during deployment, to rule out any complications and post-procedure surveillance and monitoring long term outcomes.

2.
Chinese Journal of Ultrasonography ; (12): 110-115, 2017.
Article Dans Chinois | WPRIM | ID: wpr-513946

Résumé

Objective To assess the value of transesophageal echocardiography (TEE) in left atrial appendage (LAA) closer with Amplatzer Cardiac Plug (ACP).Methods Consecutive 32 atrial fibrillation patients (CHADS2≥1) with high risk bleeding underwent LAA occlusion with ACP LAA occlusion device under the guidance of TEE.Measurements of LAA anchoring area diameter (AAD) and LAA anatomical orifice diameter (AOD) including maximum,minimum values,and LAA depth on 2 dimentional TEE (2D TEE) were conducted before closer device implantation.The outcomes of LAA occlusion were analyzed.Results Among 32 patients,27 cases achieved successful LAA occlusion,including 2 cases with peripheral leakage ≤5 mm,and 5 cases failed occlusion.Among 5 failed closed patients,3 cases with LAA AAD≥ 30 mm,1 case with LAA of short depth,and 1 case with anatomical variation of LAA of low position that access sheath could not be positioned in the LAA.LAA AAD maximum,minimum and LAA depth were (25.9±4.9)mm,(20.0±3.8)mm,(31.0±5.6)mm,respectively,and LAA AOD maximum,minimum diameters were (26.2±6.2)mm,(19.4±4.3)mm,respectively.Among 10 cases with LAA AAD≥30 mm,7 cases achieved successful LAA occlusion,but 3 cases failed.The implanted device diameter was (26.4±3.8)mm,and device compression rate was (7.6±5.5)%.The coefficient of correlation between device diameter and large LAA AAD and AOD is 0.770 and 0.717,respectively.There was no complication but 1 case with pericardial effusion.Conclusions Two dimentional TEE measurements of LAA have clinical guiding significance in the selection of proper size of ACP LAA occluder.The AAD of 2D TEE has the good correlation with ACP occluder′s size,the AADs are important factors which affect the success of LAA occlusion.

SÉLECTION CITATIONS
Détails de la recherche