Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 5 de 5
Filtre
1.
Acta ortop. bras ; 29(5): 246-248, Sept.-Oct. 2021. tab, graf
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1339065

Résumé

ABSTRACT Objective: To date, the literature lacks consensus on the most efficient method to measure the range of motion of an in vitro prosthetic system. In this study, we propose the use of a relatively low-cost online software to measure the range of motion of hip prosthetic implants manufactured in Brazil and compare its results with the current technical standards for hip arthroplasty. Methods: Three different diameters of femoral heads were evaluated (28 mm, 32 mm, and 36 mm). The mean values of the angular displacement of the prosthesis in each motion axis were obtained by computer simulations. Results: The range of motion with each femoral head was 28mm (extension/flexion: 148°, internal/external rotation: 179°, adduction/abduction: 107°), 32 mm (152°/185°/114°), and 36 mm (158°/193°/120°). Conclusion: The computational method showed that the larger the femoral head, the greater the range of motion of the hip joint prosthetic system. Additional clinical studies are necessary to compare the physical results obtained with the values found in this study by computational modeling. Level of evidence V, Experimental study.


RESUMO Objetivo: A maneira mais eficiente de se aferir a amplitude de movimento de um sistema protético in vitro ainda não é bem estabelecido na literatura. Assim, o presente estudo propõe a utilização de um software online de custo relativamente baixo para mensuração da amplitude de movimento de um conjunto protético nacional de quadril e comparar os resultados obtidos com a norma técnica vigente para as artroplastias de quadril. Métodos: A avaliação foi realizada com três diferentes diâmetros de cabeças femorais (28 mm, 32 mm e 36 mm); os valores médios do deslocamento angular da prótese em cada eixo de movimento foram obtidos por meio de simulações computacionais no programa Autodesk Inventor. Resultados: as amplitudes de movimento obtidas foram: cabeça 28mm (extensão/flexão: 148°, rotação interna/externa: 179°, adução/abdução: 107°), cabeça 32° (152°/185°/114°), cabeça 36° (158°/193°/120°). Conclusão: O método computacional utilizado no presente estudo possibilitou concluir que quanto maior a cabeça femoral, maior será a amplitude de movimento do sistema protético para articulação de quadril. Novos estudos clínicos, tanto pré quanto pós-operatórios, devem ser realizados para comparar os resultados físicos obtidos com os valores encontrados nesta avaliação por meio de modelo computacional. Nível de Evidência V, Estudo experimental.

2.
Rev. bras. anestesiol ; 69(4): 420-422, July-Aug. 2019. graf
Article Dans Anglais | LILACS | ID: biblio-1042011

Résumé

Abstract The number of total hip arthroplasty cases performed each year continues to increase; accordingly, so does the number of revision total hip arthroplasty procedures. While our traditional method of analgesia for these patients has involved multimodal medications and a continuous lumbar plexus block, we report two cases of patients who received continuous lumbar erector spinae plane blocks. Both patients exhibited excellent pain control postoperatively and were able to discharge home on postoperative day one. This case report illustrates the possible utility of continuous erector spinae plane blocks for postoperative analgesia in the more frequently occurring revision total hip arthroplasty surgeries.


Resumo O número de artroplastias totais de quadril feitas a cada ano continua a aumentar; consequentemente, o mesmo acontece com o número de procedimentos de revisão de artroplastia total de quadril. Embora nosso método tradicional de analgesia para esses pacientes tenha envolvido medicações multimodais e um bloqueio contínuo do plexo lombar, relatamos dois casos de pacientes que receberam bloqueios contínuos do músculo eretor da coluna lombar. Ambos apresentaram excelente controle da dor pós-operatória e obtiveram alta hospitalar no primeiro dia de pós-operatório. Este relato de caso ilustra a possível utilidade do bloqueio contínuo do plano do eretor da espinha para analgesia pós-operatória nas cirurgias, cada vez mais frequentes, de revisão de artroplastia total do quadril.


Sujets)
Humains , Femelle , Adulte , Douleur postopératoire/prévention et contrôle , Arthroplastie prothétique de hanche/méthodes , Bloc nerveux/méthodes , Réintervention , Adulte d'âge moyen
3.
Rev. bras. anestesiol ; 69(1): 42-47, Jan.-Feb. 2019. tab, graf
Article Dans Anglais | LILACS | ID: biblio-977425

Résumé

Abstract Background and objectives: Neutrophil to lymphocyte ratio is a simple, cost-effective and easily applicable inflammation indicator that is being used frequently in mortality, morbidity and prognosis studies in the recent years. We evaluated the relationship between neutrophil to lymphocyte ratio and postoperative pain in patients undergoing total hip arthroplasty and total knee arthroplasty. Material and methods: We included 101 patients who preferred spinal anesthesia and intravenous patient-controlled analgesia in accordance and divided them into two groups, total hip arthroplasty and total knee arthroplasty. We recorded demographic information, duration of operation, length of hospital stay, analgesics consumption, neutrophil to lymphocyte ratio results and postoperative pain using Visual Analog Scale. Results: The morphine consumption of the patients was as follows in group total hip arthroplasty and total knee arthroplasty: at the 4th hour: 7.38 mg, 7.80 mg; 8th hour: 12.19 mg, 13.29 mg; 12th hour: 16.94 mg, 19.18 mg; 24th hour: 25.97 mg, 27.98 mg; 48th hour: 36.38 mg, 39.59 mg. The Visual Analog Scale scores of the patients was as follows in group total hip arthroplasty and total knee arthroplasty: at the 4th hour: 4.10, 4.51; 8th hour: 3.02, 3.43; 12th hour: 2.29, 2.55; 24th hour: 1.90, 1.87; 48th hour: 1.08, 1.13. In group total hip arthroplasty, we found a statistically significant association between postoperative neutrophil to lymphocyte ratio and the Visual Analog Scale values on the 48th hour in a positive direction (r = 0.311; P = 0.031; P < 0.05). Conclusion: Neutrophil to lymphocyte ratio can be accepted as a relatively objective method for the diagnosis of postoperative pain.


Resumo Justificativa e objetivos: A proporção entre neutrófilo/linfócito é um indicador de inflamação simples, custo-efetivo e de fácil aplicação que vem sendo usado com frequência em estudos de mortalidade, morbidade e prognóstico nos últimos anos. Avaliamos a relação entre a proporção neutrófilo/linfócito e a dor pós-operatória em pacientes submetidos à artroplastia total de quadril e artroplastia total de joelho. Material e métodos: No total, 101 pacientes que preferiram a raquianestesia e a analgesia venosa controlada pelo paciente foram incluídos e divididos em dois grupos neste estudo: artroplastia total de quadril e artroplastia total de joelho. Os dados demográficos e os tempos de operação, internação hospitalar e consumo de analgésicos e os resultados da proporção neutrófilo/linfócito e da dor pós-operatória foram registrados usando uma escala visual analógica. Resultados: O consumo de morfina dos pacientes submetidos à artroplastia total de quadril e artroplastia total de joelho nas horas 4, 8, 12, 24 e 45 foi de, respectivamente: 7,38 mg e 7,80 mg; 12,19 mg e 13,29 mg; 16,94 mg e 19,18 mg; 25,97 mg e 27,98 mg; 36,38 mg e 39,59 mg. Os escores obtidos na escala visual analógica dos pacientes submetidos à artroplastia total de quadril e artroplastia total de joelho nas horas 4, 8, 12, 24 e 48 foram, respectivamente: 4,10 e 4,51; 3,02 e 3,43; 2,29 e 2,55; 1,90 e 1,87; 1,08 e 1,13. Na artroplastia total do quadril, uma associação estatisticamente significativa foi encontrada entre a proporção neutrófilo/linfócito no pós-operatório e os valores da escala visual analógica na 48ª hora em uma direção positiva (r = 0,311; p = 0,031; p < 0,05). Conclusão: A proporção neutrófilo/linfócito pode ser aceita como um método relativamente objetivo para o diagnóstico da dor pós-operatória.


Sujets)
Humains , Mâle , Femelle , Adolescent , Adulte , Sujet âgé , Sujet âgé de 80 ans ou plus , Jeune adulte , Douleur postopératoire/sang , Lymphocytes , Arthroplastie prothétique de hanche , Arthroplastie prothétique de genou , Granulocytes neutrophiles , Études prospectives , Numération des leucocytes , Adulte d'âge moyen
4.
Rev. bras. ortop ; 51(5): 589-596, Sept.-Oct. 2016. tab, graf
Article Dans Anglais | LILACS | ID: biblio-829998

Résumé

ABSTRACT INTRODUCTION: Total hip arthroplasty (THA) is a procedure that aims to restore the function of the hip joint. Diabetes mellitus (DM) is one of the most prevalent comorbidities among patients undergoing THA. DM involves various immunological and metabolic aspects, which lead to limitations and surgical complications. OBJECTIVE: To evaluate the association between THA complications and controlled DM during hospitalization period. METHODS: Cross-sectional research through the analysis of retrospective records of a private hospital in Salvador, Bahia. The chi-squared and Fisher's exact tests were used in SAS statistical program. RESULTS: Most patients were elderly females. The most prevalent comorbidities in the sample were hypertension and diabetes. The most frequent underlying pathology in the sample was coxarthrosis; among patients with DM, it was femoral neck fracture. The most common complications were changes in the hemolymphopoietic system, among which anemia was the most frequent complication. Cardiovascular, nervous, and blood glucose complications were positively associated with controlled DM. In turn, hemolymphopoietic, genitourinary, digestive, electrolyte, and infectious complications were not associated with DM. Having DM was a protective factor for thermal complications. There was no statistically significant difference between patients that had or did not have DM in each complication group studied. CONCLUSION: Patients with controlled DM did not present more complications than those without DM during hospitalization in the post THA.


RESUMO OBJETIVO: Avaliar a associação entre as complicações pós-ATQ e DM controlado no período da internação. MÉTODOS: Pesquisa de corte transversal por meio da análise de prontuários retrospectivos de um hospital particular em Salvador (BA). Usaram-se os testes qui-quadrado e exato de Fisher no programa estatístico SAS. RESULTADOS: A maioria dos pacientes era do sexo feminino e idosa. As comorbidades mais prevalentes da amostra foram hipertensão arterial sistêmica e DM. A patologia de base mais frequente na amostra foi coxartrose; já entre os pacientes com DM, foi fratura do colo do fêmur. As complicações mais comuns foram alterações do sistema hemolinfopoiético. Dentre essas anemia foi a complicação mais frequente. As complicações do aparelho cardiovascular, do sistema nervoso e as glicêmicas tiveram associação positiva com o DM controlado. Já as complicações hemolinfopoiéticas, geniturinárias, digestórias, eletrolíticas e infecciosas não apresentaram associação com DM. Ser portador de DM foi um fator protetor de complicações térmicas. Não houve diferença estatisticamente significante entre os pacientes portadores e não portadores de DM em nenhum dos grupos de complicações estudados. CONCLUSÃO: Os pacientes portadores de DM controlado não apresentaram mais complicações dos que os pacientes não portadores de DM durante a internação no pós-operatório da ATQ


Sujets)
Humains , Mâle , Femelle , Adulte , Adulte d'âge moyen , Sujet âgé , Arthroplastie prothétique de genou , Diabète , Complications postopératoires
5.
RBM rev. bras. med ; 67(esp.7)jun. 2010.
Article Dans Portugais | LILACS | ID: lil-564311

Résumé

Avaliamos radiograficamente e clinicamente 56 pacientes submetidos à artroplastia total de quadril com superfície metal-metal cimentada com seguimento médio de 7,7 anos. Apenas uma revisão por soltura asséptica foi realizada, porém 20,8% dos pacientes apresentaram sinais de progressão da linha de radiolucência acetabular.

SÉLECTION CITATIONS
Détails de la recherche